Effect of deep cryogenic treatment on cyclic fatigue resistance of controlled memory wire nickel-titanium rotary instruments

Background: Cryogenic methods have been used to increase the wear, abrasion, corrosion resistance and to improve the strength of metals. The aim of this study was to evaluate the effect of cryogenic treatment on the cyclic fatigue resistance of rotary nickel-titanium (NiTi) instruments. Materials an...

Full description

Bibliographic Details
Main Authors: Yazdan Sabet, Samira Shahsiah, Mohammad Yazdizadeh, Sana Baghamorady, Mansour Jafarzadeh
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2020-01-01
Series:Dental Research Journal
Subjects:
Online Access:http://www.drjjournal.net/article.asp?issn=1735-3327;year=2020;volume=17;issue=4;spage=300;epage=305;aulast=Sabet