Colorimetric chemosensor of symmetrical benzoylthiourea derivatives as for detection of Cu2+ in aqueous solution

A novel receptor, designed with a combination of oxygen (O), nitrogen (N) and sulfur (S) -binding sites for metal ions was synthesized. Ortho (A), meta (B) and para (C) bearing benzoyl thiourea were designed and synthesized with triamine group to apply as colorimetric chemosensors for detection of C...

Full description

Bibliographic Details
Main Authors: IOP, Alias, NZ (Author), Hamedan, NA (Author), Hasan, S (Author), Zaki, HM (Author)
Format: Article
Language:English
Published: 2017
Online Access:View Fulltext in Publisher
LEADER 02082nam a2200157Ia 4500
001 10.1088-1757-899X-172-1-012038
008 220223s2017 CNT 000 0 und d
100 1 |a IOP 
245 1 0 |a Colorimetric chemosensor of symmetrical benzoylthiourea derivatives as for detection of Cu2+ in aqueous solution 
260 0 |c 2017 
856 |z View Fulltext in Publisher  |u https://doi.org/10.1088/1757-899X/172/1/012038 
520 3 |a A novel receptor, designed with a combination of oxygen (O), nitrogen (N) and sulfur (S) -binding sites for metal ions was synthesized. Ortho (A), meta (B) and para (C) bearing benzoyl thiourea were designed and synthesized with triamine group to apply as colorimetric chemosensors for detection of Cu2+. The structure was confirmed by characterized the compound using Elemental analysis, Fourier Infrared (FTIR) and proton Nuclear Magnetic Resonance (H-1 NMR) spectroscopy. Functional groups of C=O, N-H, C=N and C=S were found at 1677 cm(-1), 3240 cm(-1), 1591 cm(-1), 1024 cm(-1) respectively while H-1 NMR shows peaks of alkane (CH2), benzene (Ar-H), CONH, CSNH at 3.68 - 4.14, 7.16 - 7.86, 8.74, and 9.2 respectively. Elemental analysis for A, B and C C20H21N5O2S2Br2 found was compatible with the expected theoretical calculation. For an application, all of these three sensors showed excellent colorimetric specific selectivity and high sensitivity for Cu2+ in acetonitrile/water binary solutions, so only A was selected for further studies towards sensitivity. When Cu2+ was added to the solution of A, a dramatic color change from yellow to green, while other cations Fe2+, Zn2+, Ni2+, Co2+, Cr3+ and Mn2+ did not interfere with the recognition process for Cu2+. The detection limit of the sensor C toward Cu2+ was 1.15 x 10(-5) M, which is less sensitive that sensor A and B with a detection limit of 6.2 x 10(-6) M and 1.5 x 10(-6) M respectively. This indicated that the sensor A and B might be useful as an efficient chemical sensor. 
700 1 0 |a Alias, NZ  |e author 
700 1 0 |a Hamedan, NA  |e author 
700 1 0 |a Hasan, S  |e author 
700 1 0 |a Zaki, HM  |e author