The use and limitations of continuum modes for response calculations of cellular structures

In this paper, a method for the approximate calculations of response of cellular structures is presented. The method is based on the idea that for low-frequency modes, the cellular structures behave in a way similar as a continuum does. The range of validity of the method on the mode number scale is...

Full description

Bibliographic Details
Main Authors: Banerjee, S. (Author), Bhaskar, A. (Author)
Format: Article
Language:English
Published: 2007-02-06.
Subjects:
Online Access:Get fulltext
LEADER 01119 am a22001333u 4500
001 43963
042 |a dc 
100 1 0 |a Banerjee, S.  |e author 
700 1 0 |a Bhaskar, A.  |e author 
245 0 0 |a The use and limitations of continuum modes for response calculations of cellular structures 
260 |c 2007-02-06. 
856 |z Get fulltext  |u https://eprints.soton.ac.uk/43963/1/bane_07.pdf 
520 |a In this paper, a method for the approximate calculations of response of cellular structures is presented. The method is based on the idea that for low-frequency modes, the cellular structures behave in a way similar as a continuum does. The range of validity of the method on the mode number scale is also examined. It is shown that the response is estimated very accurately from a reduced order model based on continuum modes for low-frequency vibration. The accuracy starts to deteriorate with the increase in the mode number. Beyond certain mode number, the improvement in accuracy due to the inclusion of additional continuum modes in the approxijmation shows a point of diminishing returns. illustrative examples are given. 