An electrochemical and high-speed imaging study of micropore decontamination by acoustic bubble entrapment

Electrochemical and high-speed imaging techniques are used to study the abilities of ultrasonically-activated bubbles to clean out micropores. Cylindrical pores with dimensions (diameter × depth) of 500 ?m × 400 ?m (aspect ratio 0.8), 125 ?m × 350 ?m (aspect ratio 2.8) and 50 ?m × 200 ?m (aspect rat...

Full description

Bibliographic Details
Main Authors: Offin, Douglas G. (Author), Birkin, Peter R. (Author), Leighton, Timothy G. (Author)
Format: Article
Language:English
Published: 2014-03-14.
Subjects:
Online Access:Get fulltext
LEADER 01865 am a22001573u 4500
001 365302
042 |a dc 
100 1 0 |a Offin, Douglas G.  |e author 
700 1 0 |a Birkin, Peter R.  |e author 
700 1 0 |a Leighton, Timothy G.  |e author 
245 0 0 |a An electrochemical and high-speed imaging study of micropore decontamination by acoustic bubble entrapment 
260 |c 2014-03-14. 
856 |z Get fulltext  |u https://eprints.soton.ac.uk/365302/1/c3cp55088e 
520 |a Electrochemical and high-speed imaging techniques are used to study the abilities of ultrasonically-activated bubbles to clean out micropores. Cylindrical pores with dimensions (diameter × depth) of 500 ?m × 400 ?m (aspect ratio 0.8), 125 ?m × 350 ?m (aspect ratio 2.8) and 50 ?m × 200 ?m (aspect ratio 4.0) are fabricated in glass substrates. Each pore is contaminated by filling it with an electrochemically inactive blocking organic material (thickened methyl salicylate) before the substrate is placed in a solution containing an electroactive species (Fe(CN)6(3-)). An electrode is fabricated at the base of each pore and the Faradaic current is used to monitor the decontamination as a function of time. For the largest pore, decontamination driven by ultrasound (generated by a horn type transducer) and bulk fluid flow are compared. It is shown that ultrasound is much more effective than flow alone, and that bulk fluid flow at the rates used cannot decontaminate the pore completely, but that ultrasound can. In the case of the 125 ?m pore, high-speed imaging is used to elucidate the cleaning mechanisms involved in ultrasonic decontamination and reveals that acoustic bubble entrapment is a key feature. The smallest pore is used to explore the limits of decontamination and it is found that ultrasound is still effective at this size under the conditions employed. 
540 |a other 
655 7 |a Article