Pre-clinical evaluation of ceramic femoral head resurfacing prostheses using computational models and mechanical testing
Ceramic-on-ceramic hip resurfacing can potentially offer the bone-conserving advantages of resurfacing while eliminating metal ion release. Thin-walled ceramic resurfacing heads are conceivable following developments in the strength and reliability of ceramic materials, but verification of new desig...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
2011-09.
|
Subjects: | |
Online Access: | Get fulltext Get fulltext |
LEADER | 02469 am a22001813u 4500 | ||
---|---|---|---|
001 | 195395 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Dickinson, A.S. |e author |
700 | 1 | 0 | |a Browne, M. |e author |
700 | 1 | 0 | |a Wilson, K.C. |e author |
700 | 1 | 0 | |a Jeffers, J.R.T. |e author |
700 | 1 | 0 | |a Taylor, A.C. |e author |
245 | 0 | 0 | |a Pre-clinical evaluation of ceramic femoral head resurfacing prostheses using computational models and mechanical testing |
260 | |c 2011-09. | ||
856 | |z Get fulltext |u https://eprints.soton.ac.uk/195395/1/Dickinson_2011_JEIM_DSurf.PDF | ||
856 | |z Get fulltext |u https://eprints.soton.ac.uk/195395/2/Dickinson_2011_c.pdf | ||
520 | |a Ceramic-on-ceramic hip resurfacing can potentially offer the bone-conserving advantages of resurfacing while eliminating metal ion release. Thin-walled ceramic resurfacing heads are conceivable following developments in the strength and reliability of ceramic materials, but verification of new designs is required. The present study aimed to develop a mechanical pre-clinical analysis verification process for ceramic resurfacing heads, using the DeltaSurf prosthesis design as a case study. Finite element analysis of a range of in vivo scenarios was used to design a series of physiologically representative mechanical tests, which were conducted to verify the strength of the prosthesis. Tests were designed to simulate ideal and worst-case in vivo loading and support, or to allow comparison with a clinically successful metallic device. In tests simulating ideal loading and support, the prosthesis sustained a minimum load of 39 kN before fracture, and survived 10 000 000 fatigue cycles of 0.534 kN to 5.34 kN. In worst-case tests representing a complete lack of superior femoral head bone support or pure cantile- ver loading of the prosthesis stem, the design demonstrated strength comparable to that of the equivalent metal device. The developed mechanical verification test programme represents an improvement in the state of the art where international test standards refer largely to total hip replacement prostheses. The case study's novel prosthesis design performed with considerable safety margins compared with extreme in vivo loads, providing evidence that the proposed ceramic resurfacing heads should have sufficient strength to perform safely in vivo. Similar verification tests should be designed and conducted for novel ceramic prosthesis designs in the future, leading the way to clinical evaluation | ||
655 | 7 | |a Article |