Experimental Evaluation of Load Distribution between Piles in Case of Block Failure

In this study, the load distribution of the piles in the pile group was investigated in the case of the pile raft foundations failure under the effect of vertical loads in cohesive soils. For this purpose, loading tests were carried out on model pile groups in the laboratory. In addition, the effect...

Full description

Bibliographic Details
Main Authors: Aksoy, H.S (Author), Ozpolat, A. (Author)
Format: Article
Language:English
Published: MDPI 2023
Subjects:
Online Access:View Fulltext in Publisher
View in Scopus
LEADER 02004nam a2200217Ia 4500
001 10.3390-app13095620
008 230529s2023 CNT 000 0 und d
020 |a 20763417 (ISSN) 
245 1 0 |a Experimental Evaluation of Load Distribution between Piles in Case of Block Failure 
260 0 |b MDPI  |c 2023 
856 |z View Fulltext in Publisher  |u https://doi.org/10.3390/app13095620 
856 |z View in Scopus  |u https://www.scopus.com/inward/record.uri?eid=2-s2.0-85159302393&doi=10.3390%2fapp13095620&partnerID=40&md5=596b8a890c2d4d9a1f5d132ed8c88bde 
520 3 |a In this study, the load distribution of the piles in the pile group was investigated in the case of the pile raft foundations failure under the effect of vertical loads in cohesive soils. For this purpose, loading tests were carried out on model pile groups in the laboratory. In addition, the effects of these conditions on the load distribution between the piles were examined by changing the pile spacing and soil properties. As a result of the experiments, it was determined that the piles in the corner region carried more load than the ones in the center region in small settlement amounts as in the literature. However, it has been determined that as the amount of settlement in the pile foundation increases, the soil between piles behaves like a block and approaches failure, and the piles in the center region of the pile group carry more load. As a result of excessive settlement, a fracture surface formed around the block and therefore the corner piles of the block began to carry less load. It has been determined that failure analyses should be performed considering the load carried by the corner piles after failure due to excessive settlement. © 2023 by the authors. 
650 0 4 |a clayey soil 
650 0 4 |a consolidation pressure 
650 0 4 |a model tests 
650 0 4 |a pile group 
650 0 4 |a pile load distribution 
700 1 0 |a Aksoy, H.S.  |e author 
700 1 0 |a Ozpolat, A.  |e author 
773 |t Applied Sciences (Switzerland)