PROJECT FOR MODIFYING THE SETUP FOR ADRON-55 TO IMPROVE ITS BACKGROUND CHARACTERISTICS AND A REVIEW OF UNSOLVED PROBLEMS IN STUDIES OF EXTENSIVE AIR SHOWERS

The article presents an overview of modern problems in studies of Extensive Air Showers and works devoted to their investigation. It is demonstrated that over the past decade convincing evidence of the presence of a neutron component has been demonstrated. When designing experimental facilities aime...

Full description

Bibliographic Details
Main Authors: Chechkin, A.V (Author), Iskakov, B.A (Author), Makhmet, Kh.K (Author), Novolodskaya, O.A (Author), Sadykov, T.Kh (Author)
Format: Article
Language:English
Published: E.A. Buketov Karaganda University Publish house 2023
Subjects:
Online Access:View Fulltext in Publisher
LEADER 02203nam a2200253Ia 4500
001 10.31489-2023No1-73-79
008 230526s2023 CNT 000 0 und d
020 |a 18111165 (ISSN) 
245 1 0 |a PROJECT FOR MODIFYING THE SETUP FOR ADRON-55 TO IMPROVE ITS BACKGROUND CHARACTERISTICS AND A REVIEW OF UNSOLVED PROBLEMS IN STUDIES OF EXTENSIVE AIR SHOWERS 
260 0 |b E.A. Buketov Karaganda University Publish house  |c 2023 
300 |a 7 
856 |z View Fulltext in Publisher  |u https://doi.org/10.31489/2023No1/73-79 
520 3 |a The article presents an overview of modern problems in studies of Extensive Air Showers and works devoted to their investigation. It is demonstrated that over the past decade convincing evidence of the presence of a neutron component has been demonstrated. When designing experimental facilities aimed at studying the nature of cosmic rays, this must be taken into account, since fast neutrons that arise outside the working volume can adversely affect the interpretation of the obtained data. In particular, if one tries to reveal the nature of penetrating component this effect is at most importance. Studies of biological shielding for the high flux research reactor PIK reactor at the Kurchatov Institute have shown that effective shielding from such neutrons can be provided by polyethylene in combination with borated rubber. At the same time, the use of boron-containing polyethylene does not lead to a significant improvement in protection, however, it significantly increases its cost. Based on foregoing, a modification of the hadron calorimeter protection is proposed to improve its protection it from the influence of the fast neutrons. © 2023 E.A.Buketov Karaganda State University Publish House. All rights reserved. 
650 0 4 |a cosmic rays 
650 0 4 |a extensive air showers 
650 0 4 |a high-energy particles 
650 0 4 |a ionization calorimeter 
650 0 4 |a penetrating component 
700 1 0 |a Chechkin, A.V.  |e author 
700 1 0 |a Iskakov, B.A.  |e author 
700 1 0 |a Makhmet, Kh.K.  |e author 
700 1 0 |a Novolodskaya, O.A.  |e author 
700 1 0 |a Sadykov, T.Kh.  |e author 
773 |t Eurasian Physical Technical Journal  |x 18111165 (ISSN)  |g 20 1(43), 73-79