Study of internal pressure impact on sphere tank towards vapour cloud explosion: Feyzin incident

In the case of Liquefied Petroleum Gas (LPG) tank explosion(s), risk impact assessment on the storage facilities must be carried out. Since every LPG tank has its operating condition, it is essential to decide what the best operating conditions are for each tank. This effort is made to avert an acci...

Full description

Bibliographic Details
Main Authors: Alias, A.B (Author), Rashid, Z.A (Author), Yeong, A.F.B.M.S (Author)
Format: Article
Language:English
Published: Insight Society 2018
Subjects:
LPG
Online Access:View Fulltext in Publisher
View in Scopus
LEADER 02307nam a2200241Ia 4500
001 10.18517-ijaseit.8.6.5409
008 220120s2018 CNT 000 0 und d
020 |a 20885334 (ISSN) 
245 1 0 |a Study of internal pressure impact on sphere tank towards vapour cloud explosion: Feyzin incident 
260 0 |b Insight Society  |c 2018 
490 1 |t International Journal on Advanced Science, Engineering and Information Technology 
650 0 4 |a Explosion 
650 0 4 |a Feyzin 
650 0 4 |a LPG 
650 0 4 |a Peak side-on overpressure 
650 0 4 |a Planas-cuchi 
856 |z View Fulltext in Publisher  |u https://doi.org/10.18517/ijaseit.8.6.5409 
856 |z View in Scopus  |u https://www.scopus.com/inward/record.uri?eid=2-s2.0-85059514687&doi=10.18517%2fijaseit.8.6.5409&partnerID=40&md5=40e3b96f2f37d8e7475f783283e1664c 
520 3 |a In the case of Liquefied Petroleum Gas (LPG) tank explosion(s), risk impact assessment on the storage facilities must be carried out. Since every LPG tank has its operating condition, it is essential to decide what the best operating conditions are for each tank. This effort is made to avert an accident from happening, as fires and explosions can be devastating in terms of lives lost and destruction to buildings and the environment. Boil-off and/or ignition of flammable gas can cause the pressure in the tank to increase. Therefore, a method called Planas-Cuchi is applied to determine the Peak Side-On Overpressure, Po, of the LPG tank during the occurrence of explosion. Thermodynamic properties of saturated propane, C3H8, has been chosen as a reference and basis of calculation to determine the parameters involved, such as Explosion Energy, E, Equivalent Mass of TNT, WTNT, and Scaled Overpressure, PS. A cylindrical LPG tank in Feyzin Refinery, France is selected as a point of study in this research. At the end of this study, the most suitable operating pressure of the LPG tank will be determined, and the results are compared and validated using the TNT Equivalent (BREEZE software), Baker-Strehlow model and ARIA investigation report. © 2018 Insight Society. 
700 1 0 |a Alias, A.B.  |e author 
700 1 0 |a Rashid, Z.A.  |e author 
700 1 0 |a Yeong, A.F.B.M.S.  |e author 
773 |t International Journal on Advanced Science, Engineering and Information Technology