ETOU electricity tariff for manufacturing load shifting strategy using ACO algorithm
This paper presents load shifting strategy for cost reduction on manufacturing electricity demand side, by which a real test load profile had been used to prove the concept. Superior bio-inspired algorithm, Ant Colony Optimization (ACO) had been implemented to optimize the upright load profile of lo...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Institute of Advanced Engineering and Science
2019
|
Subjects: | |
Online Access: | View Fulltext in Publisher View in Scopus |
LEADER | 02088nam a2200265Ia 4500 | ||
---|---|---|---|
001 | 10.11591-eei.v8i1.1438 | ||
008 | 220121s2019 CNT 000 0 und d | ||
020 | |a 20893191 (ISSN) | ||
245 | 1 | 0 | |a ETOU electricity tariff for manufacturing load shifting strategy using ACO algorithm |
260 | 0 | |b Institute of Advanced Engineering and Science |c 2019 | |
650 | 0 | 4 | |a Ant Colony Optimization (ACO) |
650 | 0 | 4 | |a Demand Side Management (DSM) |
650 | 0 | 4 | |a Enhance time of use (ETOU) |
650 | 0 | 4 | |a Load profile |
650 | 0 | 4 | |a Load shifting |
856 | |z View Fulltext in Publisher |u https://doi.org/10.11591/eei.v8i1.1438 | ||
856 | |z View in Scopus |u https://www.scopus.com/inward/record.uri?eid=2-s2.0-85065595087&doi=10.11591%2feei.v8i1.1438&partnerID=40&md5=04ea2d9fd9654dd07c0d74eb3614adcc | ||
520 | 3 | |a This paper presents load shifting strategy for cost reduction on manufacturing electricity demand side, by which a real test load profile had been used to prove the concept. Superior bio-inspired algorithm, Ant Colony Optimization (ACO) had been implemented to optimize the upright load profile of load shifting strategy in the Malaysia Enhance Time of Use (ETOU) tariff condition. Subsequently, significant simulation results of operation profit gain through 24 hours electricity consumption had been analyzed properly. The proposed method had shown reduction of approximately 6% of the electricity cost at peak and mid peak zones, when 20%, 40%, 60%, 80% and 100% load shifting weightages were applied to the identified 10% controlled loads consequently. It is hoped that the finding of this study can help poise the manufacturers to switch to ETOU tariff as well as support the national Demand Side Management (DSM) program. © 2019 Institute of Advanced Engineering and Science. | |
700 | 1 | 0 | |a Dahlan, N.Y. |e author |
700 | 1 | 0 | |a Isa, M.H. |e author |
700 | 1 | 0 | |a Kasdirin, H.A. |e author |
700 | 1 | 0 | |a Othman, M.N. |e author |
700 | 1 | 0 | |a Sulaima, M.F. |e author |
700 | 1 | 0 | |a Yasin, Z.M. |e author |
773 | |t Bulletin of Electrical Engineering and Informatics |x 20893191 (ISSN) |g 8 1, 21-29 |