Intensity crack zones of reinforced concrete beam under monotonic loading

This paper presents the intensity crack zones of reinforced concrete (RC) beam under monotonic loading in conjunction with acoustic emission (AE) monitoring. Five RC beam size 200 mm x 300 mm x 1500 mm were prepared and tested. Due to similar pattern in term of the crack pattern and the analysis, on...

Full description

Bibliographic Details
Main Authors: Abd Rahman, N. (Author), Kamaruzzaman, K.N (Author), Mat Saliah, S.N (Author), Mohd Mesron, M.A (Author), Nor, N.M (Author)
Format: Article
Language:English
Published: Institute of Physics Publishing 2019
Subjects:
Online Access:View Fulltext in Publisher
View in Scopus
LEADER 02068nas a2200325Ia 4500
001 10.1088-1742-6596-1349-1-012086
008 220121c20199999CNT?? ? 0 0und d
020 |a 17426588 (ISSN) 
245 1 0 |a Intensity crack zones of reinforced concrete beam under monotonic loading 
260 0 |b Institute of Physics Publishing  |c 2019 
650 0 4 |a Acoustic emission testing 
650 0 4 |a AE signals 
650 0 4 |a Concrete beams and girders 
650 0 4 |a Crack mode 
650 0 4 |a Crack patterns 
650 0 4 |a Intensity analysis 
650 0 4 |a Monotonic loading 
650 0 4 |a Nanostructured materials 
650 0 4 |a Reinforced concrete 
650 0 4 |a Reinforced concrete beams 
650 0 4 |a Severity index 
650 0 4 |a Similar pattern 
856 |z View Fulltext in Publisher  |u https://doi.org/10.1088/1742-6596/1349/1/012086 
856 |z View in Scopus  |u https://www.scopus.com/inward/record.uri?eid=2-s2.0-85077793850&doi=10.1088%2f1742-6596%2f1349%2f1%2f012086&partnerID=40&md5=736245b836c19e85a593ffedd8062e49 
520 3 |a This paper presents the intensity crack zones of reinforced concrete (RC) beam under monotonic loading in conjunction with acoustic emission (AE) monitoring. Five RC beam size 200 mm x 300 mm x 1500 mm were prepared and tested. Due to similar pattern in term of the crack pattern and the analysis, only one beam was presented in this paper. The intensity crack zones were performed by mean of historic and severity indices at sensor 6 (CH6) and sensor 7 (CH7). The plot in the intensity crack zone was based on the crack mode performed during testing. As a result, the progression of the crack was well-matched with the plots in the intensity crack zones. In a nutshell, the data obtained from the AE signal and analyse using intensity analysis, it can be used to classify damage in the RC beam. © Published under licence by IOP Publishing Ltd. 
700 1 0 |a Abd Rahman, N.  |e author  
700 1 0 |a Kamaruzzaman, K.N.  |e author  
700 1 0 |a Mat Saliah, S.N.  |e author  
700 1 0 |a Mohd Mesron, M.A.  |e author  
700 1 0 |a Nor, N.M.  |e author