Diagnostic value of loop-mediated isothermal amplification assay for hand, foot, and mouth disease

Background: Nowadays, hand, foot, and mouth disease (HFMD) has a significant negative impact on children's health, especially in the Asia-Pacific region. Loop-mediated isothermal amplification assay (LAMP) is a highly efficient and convenient novel tool. However, its diagnostic accuracy for HFM...

Full description

Bibliographic Details
Main Authors: Cao, X.-J (Author), Chen, M.-S (Author), Chen, Y.-Z (Author), Guo, X.-G (Author), Li, Y.-P (Author), Zhan, Z.-Q (Author), Zhou, L.-Q (Author)
Format: Article
Language:English
Published: John Wiley and Sons Inc 2021
Subjects:
Online Access:View Fulltext in Publisher
Description
Summary:Background: Nowadays, hand, foot, and mouth disease (HFMD) has a significant negative impact on children's health, especially in the Asia-Pacific region. Loop-mediated isothermal amplification assay (LAMP) is a highly efficient and convenient novel tool. However, its diagnostic accuracy for HFMD is still not clear. Therefore, we conducted a meta-analysis in order to evaluate the potential of LAMP assay for the diagnosis of HFMD, in which the reference standard was polymerase chain reaction (PCR). Methods: A protocol was predetermined (CRD42020212882) in PROSPERO. We retrieved seven databases including PubMed for relevant studies published before October 2020. Articles were included if they compared the diagnostic efficiency of LAMP with PCR for HFMD through detecting clinical samples which was more than 15. Statistical analysis was performed by STATA 15.1 software. Risk of bias and applicability were assessed using Quality Assessment of Diagnostic Accuracy Studies. No funding was used for the study. Results: A total of 18 retrospective studies including 2495 samples from China were finally included. Reference standards of them included RT-PCR and non-RT-PCR. The merged sensitivity and specificity with 95% confidence interval (95% CI) were 1.00 (0.97–1.00) and 0.97 (0.88–0.99), respectively. The pooled PLR, NLR, and DOR with 95% CI were 11.17 (5.91–21.11), 0.05 (0.03–0.09), and 538.12 (183.17–1580.83), respectively. The AUC of SROC was 1.00 (95% CI: 0.99–1.00). Conclusion: In conclusion, our research revealed high sensitivity and specificity of LAMP in diagnosing HFMD. However, more high-quality research is required to prove this conclusion. © 2021 The Authors. Journal of Clinical Laboratory Analysis published by Wiley Periodicals LLC
ISBN:08878013 (ISSN)
DOI:10.1002/jcla.23776