Cross Contamination in Levered Endoscopes

Contamination is a prevalent issue with reprocessed levered endoscopes. The number of infections caused by resistant enterobacteriaceae in patients due to contaminated endoscopes increased to the point that the United States Food and Drug Administration released a safety alert to health care facilit...

Full description

Bibliographic Details
Main Author: Thomason Jr., Ernest Lowell
Format: Others
Language:en
Published: ScholarWorks 2018
Subjects:
Online Access:https://scholarworks.waldenu.edu/dissertations/6138
https://scholarworks.waldenu.edu/cgi/viewcontent.cgi?article=7417&context=dissertations
id ndltd-waldenu.edu-oai-scholarworks.waldenu.edu-dissertations-7417
record_format oai_dc
spelling ndltd-waldenu.edu-oai-scholarworks.waldenu.edu-dissertations-74172019-10-30T01:10:29Z Cross Contamination in Levered Endoscopes Thomason Jr., Ernest Lowell Contamination is a prevalent issue with reprocessed levered endoscopes. The number of infections caused by resistant enterobacteriaceae in patients due to contaminated endoscopes increased to the point that the United States Food and Drug Administration released a safety alert to health care facilities that perform endoscopic retrograde cholangiopancreatography (ERCP). The purpose of this descriptive project was to evaluate if levered endoscopes used in ERCP procedures met high level disinfection criteria, were properly processed, and were germ free after reprocessing. The project was supported by 2 theories: the middle range theory of patient advocacy and the germ theory. Data (counts and percentages) were collected from testing 150 endoscopes at each of 4 facilities within an organization regarding the effectiveness of the reprocessing of the levered endoscopes. According to the project findings, there was a 7% average germ-free failure rate across the sites after the initial reprocessing. The cleaning process of the levered endoscopes allowed bacteria to remain on the scopes after the manufacturer-recommended cleaning was completed at the sites. Standardization of the organization's cleaning process and improvement in the national protocols were recommended. The project supported protecting the safety of endoscopy patients by identifying that the cleaning process could be improved to prevent introduction of infectious bacteria through a procedure. The results will be informative for laboratory staff who clean levered endoscopes, physicians who use the scopes in patient procedures, patients who undergo the procedures, and nurses who are tasked with improving patient safety in perioperative environments. 2018-01-01T08:00:00Z text application/pdf https://scholarworks.waldenu.edu/dissertations/6138 https://scholarworks.waldenu.edu/cgi/viewcontent.cgi?article=7417&context=dissertations Walden Dissertations and Doctoral Studies en ScholarWorks carbapenem-resistant enterobacteriaceae cross contamination endoscopy levered endoscopes reprocessed validation Nursing
collection NDLTD
language en
format Others
sources NDLTD
topic carbapenem-resistant enterobacteriaceae
cross contamination
endoscopy
levered endoscopes
reprocessed
validation
Nursing
spellingShingle carbapenem-resistant enterobacteriaceae
cross contamination
endoscopy
levered endoscopes
reprocessed
validation
Nursing
Thomason Jr., Ernest Lowell
Cross Contamination in Levered Endoscopes
description Contamination is a prevalent issue with reprocessed levered endoscopes. The number of infections caused by resistant enterobacteriaceae in patients due to contaminated endoscopes increased to the point that the United States Food and Drug Administration released a safety alert to health care facilities that perform endoscopic retrograde cholangiopancreatography (ERCP). The purpose of this descriptive project was to evaluate if levered endoscopes used in ERCP procedures met high level disinfection criteria, were properly processed, and were germ free after reprocessing. The project was supported by 2 theories: the middle range theory of patient advocacy and the germ theory. Data (counts and percentages) were collected from testing 150 endoscopes at each of 4 facilities within an organization regarding the effectiveness of the reprocessing of the levered endoscopes. According to the project findings, there was a 7% average germ-free failure rate across the sites after the initial reprocessing. The cleaning process of the levered endoscopes allowed bacteria to remain on the scopes after the manufacturer-recommended cleaning was completed at the sites. Standardization of the organization's cleaning process and improvement in the national protocols were recommended. The project supported protecting the safety of endoscopy patients by identifying that the cleaning process could be improved to prevent introduction of infectious bacteria through a procedure. The results will be informative for laboratory staff who clean levered endoscopes, physicians who use the scopes in patient procedures, patients who undergo the procedures, and nurses who are tasked with improving patient safety in perioperative environments.
author Thomason Jr., Ernest Lowell
author_facet Thomason Jr., Ernest Lowell
author_sort Thomason Jr., Ernest Lowell
title Cross Contamination in Levered Endoscopes
title_short Cross Contamination in Levered Endoscopes
title_full Cross Contamination in Levered Endoscopes
title_fullStr Cross Contamination in Levered Endoscopes
title_full_unstemmed Cross Contamination in Levered Endoscopes
title_sort cross contamination in levered endoscopes
publisher ScholarWorks
publishDate 2018
url https://scholarworks.waldenu.edu/dissertations/6138
https://scholarworks.waldenu.edu/cgi/viewcontent.cgi?article=7417&context=dissertations
work_keys_str_mv AT thomasonjrernestlowell crosscontaminationinleveredendoscopes
_version_ 1719281507541975040