Evaluation of the Safety of MRI Scanning of Patients with MR Conditional Pacemakers

Magnetic resonance imaging (MRI) of patients with cardiac implantable electronic devices (CIED) has been associated with risks such as device/lead movement, device dysfunction, and lead heating. New technological advancements have made it possible for MRI to be safely performed when adhering to an e...

Full description

Bibliographic Details
Main Author: McGurk, Shelly Lynn
Format: Others
Language:en
Published: ScholarWorks 2017
Subjects:
MRI
Online Access:https://scholarworks.waldenu.edu/dissertations/4009
https://scholarworks.waldenu.edu/cgi/viewcontent.cgi?article=5112&context=dissertations
id ndltd-waldenu.edu-oai-scholarworks.waldenu.edu-dissertations-5112
record_format oai_dc
spelling ndltd-waldenu.edu-oai-scholarworks.waldenu.edu-dissertations-51122019-10-30T01:18:33Z Evaluation of the Safety of MRI Scanning of Patients with MR Conditional Pacemakers McGurk, Shelly Lynn Magnetic resonance imaging (MRI) of patients with cardiac implantable electronic devices (CIED) has been associated with risks such as device/lead movement, device dysfunction, and lead heating. New technological advancements have made it possible for MRI to be safely performed when adhering to an evidence-based protocol; however, this practice has not yet been widely adopted. The purpose of this practice-focused question project was to examine the safety of MRI as a diagnostic modality for the aggregate population of adult patients with MR conditional pacemakers when a nurse-practitioner-led, evidence-based protocol was used. The Iowa model served as the guide for implementation of the program, and the Donabedian framework was used to evaluate the program through process, structure, and outcomes. Evidence was obtained through a documentation template that served as the procedural record in the electronic health record. Demographic information, program fidelity, and manufacturer adherence were analyzed through descriptive statistics. Clinical outcomes related to device function were measured pre- and post- MRI and analyzed with chi square and paired t-test inferential statistics to determine if statistically significant change occurs in the setting of MRI scanning. According to data analysis of 34 studies, there were no statistically significant changes in lead impedance, pacing thresholds, or patient reported symptoms pre- and post- MRI. The pilot program has been recommended for organizational adoption and will increase the scope of advanced practice nurses within the organization and provide the CIED aggregate population with access to an important diagnostic modality. 2017-01-01T08:00:00Z text application/pdf https://scholarworks.waldenu.edu/dissertations/4009 https://scholarworks.waldenu.edu/cgi/viewcontent.cgi?article=5112&context=dissertations Walden Dissertations and Doctoral Studies en ScholarWorks MRI Pacemaker Nursing
collection NDLTD
language en
format Others
sources NDLTD
topic MRI
Pacemaker
Nursing
spellingShingle MRI
Pacemaker
Nursing
McGurk, Shelly Lynn
Evaluation of the Safety of MRI Scanning of Patients with MR Conditional Pacemakers
description Magnetic resonance imaging (MRI) of patients with cardiac implantable electronic devices (CIED) has been associated with risks such as device/lead movement, device dysfunction, and lead heating. New technological advancements have made it possible for MRI to be safely performed when adhering to an evidence-based protocol; however, this practice has not yet been widely adopted. The purpose of this practice-focused question project was to examine the safety of MRI as a diagnostic modality for the aggregate population of adult patients with MR conditional pacemakers when a nurse-practitioner-led, evidence-based protocol was used. The Iowa model served as the guide for implementation of the program, and the Donabedian framework was used to evaluate the program through process, structure, and outcomes. Evidence was obtained through a documentation template that served as the procedural record in the electronic health record. Demographic information, program fidelity, and manufacturer adherence were analyzed through descriptive statistics. Clinical outcomes related to device function were measured pre- and post- MRI and analyzed with chi square and paired t-test inferential statistics to determine if statistically significant change occurs in the setting of MRI scanning. According to data analysis of 34 studies, there were no statistically significant changes in lead impedance, pacing thresholds, or patient reported symptoms pre- and post- MRI. The pilot program has been recommended for organizational adoption and will increase the scope of advanced practice nurses within the organization and provide the CIED aggregate population with access to an important diagnostic modality.
author McGurk, Shelly Lynn
author_facet McGurk, Shelly Lynn
author_sort McGurk, Shelly Lynn
title Evaluation of the Safety of MRI Scanning of Patients with MR Conditional Pacemakers
title_short Evaluation of the Safety of MRI Scanning of Patients with MR Conditional Pacemakers
title_full Evaluation of the Safety of MRI Scanning of Patients with MR Conditional Pacemakers
title_fullStr Evaluation of the Safety of MRI Scanning of Patients with MR Conditional Pacemakers
title_full_unstemmed Evaluation of the Safety of MRI Scanning of Patients with MR Conditional Pacemakers
title_sort evaluation of the safety of mri scanning of patients with mr conditional pacemakers
publisher ScholarWorks
publishDate 2017
url https://scholarworks.waldenu.edu/dissertations/4009
https://scholarworks.waldenu.edu/cgi/viewcontent.cgi?article=5112&context=dissertations
work_keys_str_mv AT mcgurkshellylynn evaluationofthesafetyofmriscanningofpatientswithmrconditionalpacemakers
_version_ 1719281792487260160