DEVELOPMENT AND INVESTIGATION OF INTENSITY-MODULATED RADIATION THERAPY TREATMENT PLANNING FOR FOUR-DIMENSIONAL ANATOMY

Lung cancer is the leading cause of cancer-related deaths worldwide. Radiotherapy is one of the main treatment modalities of lung cancer. However, the achievable accuracy of radiotherapy treatment is limited for lung-based tumors due to respiratory motion. Four-dimensional radiotherapy explicitly ac...

Full description

Bibliographic Details
Main Author: suh, yelin
Format: Others
Published: VCU Scholars Compass 2009
Subjects:
Online Access:http://scholarscompass.vcu.edu/etd/1827
http://scholarscompass.vcu.edu/cgi/viewcontent.cgi?article=2826&context=etd
id ndltd-vcu.edu-oai-scholarscompass.vcu.edu-etd-2826
record_format oai_dc
spelling ndltd-vcu.edu-oai-scholarscompass.vcu.edu-etd-28262017-03-17T08:29:07Z DEVELOPMENT AND INVESTIGATION OF INTENSITY-MODULATED RADIATION THERAPY TREATMENT PLANNING FOR FOUR-DIMENSIONAL ANATOMY suh, yelin Lung cancer is the leading cause of cancer-related deaths worldwide. Radiotherapy is one of the main treatment modalities of lung cancer. However, the achievable accuracy of radiotherapy treatment is limited for lung-based tumors due to respiratory motion. Four-dimensional radiotherapy explicitly accounts for anatomic motion by characterizing the motion, creating a treatment plan that accounts for this motion, and delivering this plan to the moving anatomy. This thesis focuses on the current problems and solutions throughout the course of four-dimensional radiotherapy. For characterization of respiratory-induced motion, patient tumor motion data were analyzed. It is shown that tumor motion can be significant during radiotherapy treatment, and its extent, direction, and linearity vary considerably between patients, between treatment fractions, and between respiratory cycles. After this, approaches to four-dimensional intensity-modulated radiation therapy treatment planning were developed and investigated. Among the techniques to manage respiratory motion, tumor tracking using a dynamic multileaf collimator delivery technique was chosen as a promising method. A formalism to solve a general four-dimensional intensity-modulated radiation therapy treatment-planning problem was developed. Specific solutions to this problem accounting for tumor motion initially in one dimension and extending this to three dimensions were developed and investigated using four-dimensional computed tomography planning scans of lung cancer patients. For four-dimensional radiotherapy treatment delivery, accuracy of two-dimensional projection imaging methods was investigated. Geometric uncertainty due to the limitation of two-dimensional imaging in monitoring three-dimensional tumor motion during treatment delivery was quantified. This geometric uncertainty can be used to estimate proper margins when a single two-dimensional projection imager is used for four-dimensional treatment delivery. Lastly, tumor-tracking delivery using a moving average algorithm was investigated as an alternative delivery technique that reduces mechanical motion constraints of a multileaf collimator. Moving average tracking provides an approximate solution that can be immediately implemented for delivery of four-dimensional intensity-modulated radiation therapy treatment. The clinical implementation of four-dimensional guidance, intensity-modulated radiation therapy treatment planning, and dynamic multileaf collimator tracking delivery may have a positive impact on the treatment of lung cancer. 2009-05-06T07:00:00Z text application/pdf http://scholarscompass.vcu.edu/etd/1827 http://scholarscompass.vcu.edu/cgi/viewcontent.cgi?article=2826&context=etd © The Author Theses and Dissertations VCU Scholars Compass radiotherapy lung cancer IMRT treatment planning respiratory motion 4D radiotherapy Physical Sciences and Mathematics Physics
collection NDLTD
format Others
sources NDLTD
topic radiotherapy
lung cancer
IMRT
treatment planning
respiratory motion
4D radiotherapy
Physical Sciences and Mathematics
Physics
spellingShingle radiotherapy
lung cancer
IMRT
treatment planning
respiratory motion
4D radiotherapy
Physical Sciences and Mathematics
Physics
suh, yelin
DEVELOPMENT AND INVESTIGATION OF INTENSITY-MODULATED RADIATION THERAPY TREATMENT PLANNING FOR FOUR-DIMENSIONAL ANATOMY
description Lung cancer is the leading cause of cancer-related deaths worldwide. Radiotherapy is one of the main treatment modalities of lung cancer. However, the achievable accuracy of radiotherapy treatment is limited for lung-based tumors due to respiratory motion. Four-dimensional radiotherapy explicitly accounts for anatomic motion by characterizing the motion, creating a treatment plan that accounts for this motion, and delivering this plan to the moving anatomy. This thesis focuses on the current problems and solutions throughout the course of four-dimensional radiotherapy. For characterization of respiratory-induced motion, patient tumor motion data were analyzed. It is shown that tumor motion can be significant during radiotherapy treatment, and its extent, direction, and linearity vary considerably between patients, between treatment fractions, and between respiratory cycles. After this, approaches to four-dimensional intensity-modulated radiation therapy treatment planning were developed and investigated. Among the techniques to manage respiratory motion, tumor tracking using a dynamic multileaf collimator delivery technique was chosen as a promising method. A formalism to solve a general four-dimensional intensity-modulated radiation therapy treatment-planning problem was developed. Specific solutions to this problem accounting for tumor motion initially in one dimension and extending this to three dimensions were developed and investigated using four-dimensional computed tomography planning scans of lung cancer patients. For four-dimensional radiotherapy treatment delivery, accuracy of two-dimensional projection imaging methods was investigated. Geometric uncertainty due to the limitation of two-dimensional imaging in monitoring three-dimensional tumor motion during treatment delivery was quantified. This geometric uncertainty can be used to estimate proper margins when a single two-dimensional projection imager is used for four-dimensional treatment delivery. Lastly, tumor-tracking delivery using a moving average algorithm was investigated as an alternative delivery technique that reduces mechanical motion constraints of a multileaf collimator. Moving average tracking provides an approximate solution that can be immediately implemented for delivery of four-dimensional intensity-modulated radiation therapy treatment. The clinical implementation of four-dimensional guidance, intensity-modulated radiation therapy treatment planning, and dynamic multileaf collimator tracking delivery may have a positive impact on the treatment of lung cancer.
author suh, yelin
author_facet suh, yelin
author_sort suh, yelin
title DEVELOPMENT AND INVESTIGATION OF INTENSITY-MODULATED RADIATION THERAPY TREATMENT PLANNING FOR FOUR-DIMENSIONAL ANATOMY
title_short DEVELOPMENT AND INVESTIGATION OF INTENSITY-MODULATED RADIATION THERAPY TREATMENT PLANNING FOR FOUR-DIMENSIONAL ANATOMY
title_full DEVELOPMENT AND INVESTIGATION OF INTENSITY-MODULATED RADIATION THERAPY TREATMENT PLANNING FOR FOUR-DIMENSIONAL ANATOMY
title_fullStr DEVELOPMENT AND INVESTIGATION OF INTENSITY-MODULATED RADIATION THERAPY TREATMENT PLANNING FOR FOUR-DIMENSIONAL ANATOMY
title_full_unstemmed DEVELOPMENT AND INVESTIGATION OF INTENSITY-MODULATED RADIATION THERAPY TREATMENT PLANNING FOR FOUR-DIMENSIONAL ANATOMY
title_sort development and investigation of intensity-modulated radiation therapy treatment planning for four-dimensional anatomy
publisher VCU Scholars Compass
publishDate 2009
url http://scholarscompass.vcu.edu/etd/1827
http://scholarscompass.vcu.edu/cgi/viewcontent.cgi?article=2826&context=etd
work_keys_str_mv AT suhyelin developmentandinvestigationofintensitymodulatedradiationtherapytreatmentplanningforfourdimensionalanatomy
_version_ 1718428401747886080