Technical cost of operating a PV installation as a STATCOM during nightime.
Reactive power support by photovoltaic farms has been under discussion in several countries. This kind of operation has been proposed because the photovoltaic farm converter is an expensive asset that is often used well below its power rating. This paper proposes a methodology for estimating the rea...
Main Author: | |
---|---|
Other Authors: | |
Format: | Others |
Language: | en |
Published: |
Biblioteca Digitais de Teses e Dissertações da USP
2017
|
Subjects: | |
Online Access: | http://www.teses.usp.br/teses/disponiveis/3/3143/tde-23102017-104035/ |
id |
ndltd-usp.br-oai-teses.usp.br-tde-23102017-104035 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-usp.br-oai-teses.usp.br-tde-23102017-1040352019-05-09T21:06:16Z Technical cost of operating a PV installation as a STATCOM during nightime. Avaliação do custo técnico da operação de uma fazenda solar fotovoltaica como um STATCOM no período da noite. Lourenço, Luís Felipe Normandia Conversores elétricos Energia solar Photovoltaic solar farms Power losses Sistemas fotovoltaicos Statcom Reactive power support by photovoltaic farms has been under discussion in several countries. This kind of operation has been proposed because the photovoltaic farm converter is an expensive asset that is often used well below its power rating. This paper proposes a methodology for estimating the reactive power support capability and the associated technical cost of operating a photovoltaic installation as a STATCOM at nighttime. The technical cost is related to the need to buy active power from the grid to compensate for power losses. A precise estimation of this cost is of interest for both photovoltaic farm owners and grid operators to be able to evaluate the economic feasibility of this kind of operation. In order to illustrate the proposed methodology, a 1.5 MWp photovoltaic farm is considered. By evaluating the losses of each component (converter, tie reactor, filter and transformer), a reactive power support capability map integrating the technical cost for each point of operation is obtained. The analysis outlines key points to operate a PV farm as a STATCOM at nighttime: the system must include a blocking diode, the capability map is asymmetric, an operation with variable DC-link voltage is desirable and can lead to savings of up to 8.9 % in comparison with operation at fixed nominal DC-link voltage. O suporte de potência reativa por fazendas solares fotovoltaicas está sob discussão em diversos países. Este tipo de operação foi proposta pois o conversor das fazendas solares é um equipamento de custo elevado que é usualmente utilizado abaixo de sua potência nominal. Este trabalho propõe uma metodologia para estimar a capabilidade de suporte de reativos e o custo técnico associado na operação de uma fazenda solar fotovoltaica como um STATCOM durante o período da noite. O custo técnico desta operação está associado à necessidade da compra de potência ativa da rede elétrica para suprir as perdas de energia para compensar as perdas nos equipamentos. Uma estimativa precisa deste custo técnico é de interesse tanto dos empreendedores que possuem fazendas fotovoltaicas como dos operadores da rede elétrica para que se avalie a viabilidade econômica deste tipo de operação. Para ilustrar a metodologia proposta, uma fazenda solar fotovoltaica de 1.5 MWp é considerada. Através da avaliação das perdas em cada componente (conversor, reator, filtro e transformador), um mapa de capabilidade de suporte de potência reativa é obtido integrando os custos técnicos para cada ponto de operação. A análise realizada neste trabalho destaca os pontos chave para a operação noturna de uma fazenda solar como STATCOM: o sistema deve incluir um diodo de bloqueio, o mapa de capabilidade é assimétrico, a operação com tensão do circuito CC é desejável e resulta em economia de energia de 8.9 % em comparação com operação com a operação em tensão nominal fixa do circuito CC. Biblioteca Digitais de Teses e Dissertações da USP Monaro, Renato Machado Salles, Maurício Barbosa de Camargo 2017-08-01 Dissertação de Mestrado application/pdf http://www.teses.usp.br/teses/disponiveis/3/3143/tde-23102017-104035/ en Liberar o conteúdo para acesso público. |
collection |
NDLTD |
language |
en |
format |
Others
|
sources |
NDLTD |
topic |
Conversores elétricos Energia solar Photovoltaic solar farms Power losses Sistemas fotovoltaicos Statcom |
spellingShingle |
Conversores elétricos Energia solar Photovoltaic solar farms Power losses Sistemas fotovoltaicos Statcom Lourenço, Luís Felipe Normandia Technical cost of operating a PV installation as a STATCOM during nightime. |
description |
Reactive power support by photovoltaic farms has been under discussion in several countries. This kind of operation has been proposed because the photovoltaic farm converter is an expensive asset that is often used well below its power rating. This paper proposes a methodology for estimating the reactive power support capability and the associated technical cost of operating a photovoltaic installation as a STATCOM at nighttime. The technical cost is related to the need to buy active power from the grid to compensate for power losses. A precise estimation of this cost is of interest for both photovoltaic farm owners and grid operators to be able to evaluate the economic feasibility of this kind of operation. In order to illustrate the proposed methodology, a 1.5 MWp photovoltaic farm is considered. By evaluating the losses of each component (converter, tie reactor, filter and transformer), a reactive power support capability map integrating the technical cost for each point of operation is obtained. The analysis outlines key points to operate a PV farm as a STATCOM at nighttime: the system must include a blocking diode, the capability map is asymmetric, an operation with variable DC-link voltage is desirable and can lead to savings of up to 8.9 % in comparison with operation at fixed nominal DC-link voltage. === O suporte de potência reativa por fazendas solares fotovoltaicas está sob discussão em diversos países. Este tipo de operação foi proposta pois o conversor das fazendas solares é um equipamento de custo elevado que é usualmente utilizado abaixo de sua potência nominal. Este trabalho propõe uma metodologia para estimar a capabilidade de suporte de reativos e o custo técnico associado na operação de uma fazenda solar fotovoltaica como um STATCOM durante o período da noite. O custo técnico desta operação está associado à necessidade da compra de potência ativa da rede elétrica para suprir as perdas de energia para compensar as perdas nos equipamentos. Uma estimativa precisa deste custo técnico é de interesse tanto dos empreendedores que possuem fazendas fotovoltaicas como dos operadores da rede elétrica para que se avalie a viabilidade econômica deste tipo de operação. Para ilustrar a metodologia proposta, uma fazenda solar fotovoltaica de 1.5 MWp é considerada. Através da avaliação das perdas em cada componente (conversor, reator, filtro e transformador), um mapa de capabilidade de suporte de potência reativa é obtido integrando os custos técnicos para cada ponto de operação. A análise realizada neste trabalho destaca os pontos chave para a operação noturna de uma fazenda solar como STATCOM: o sistema deve incluir um diodo de bloqueio, o mapa de capabilidade é assimétrico, a operação com tensão do circuito CC é desejável e resulta em economia de energia de 8.9 % em comparação com operação com a operação em tensão nominal fixa do circuito CC. |
author2 |
Monaro, Renato Machado |
author_facet |
Monaro, Renato Machado Lourenço, Luís Felipe Normandia |
author |
Lourenço, Luís Felipe Normandia |
author_sort |
Lourenço, Luís Felipe Normandia |
title |
Technical cost of operating a PV installation as a STATCOM during nightime. |
title_short |
Technical cost of operating a PV installation as a STATCOM during nightime. |
title_full |
Technical cost of operating a PV installation as a STATCOM during nightime. |
title_fullStr |
Technical cost of operating a PV installation as a STATCOM during nightime. |
title_full_unstemmed |
Technical cost of operating a PV installation as a STATCOM during nightime. |
title_sort |
technical cost of operating a pv installation as a statcom during nightime. |
publisher |
Biblioteca Digitais de Teses e Dissertações da USP |
publishDate |
2017 |
url |
http://www.teses.usp.br/teses/disponiveis/3/3143/tde-23102017-104035/ |
work_keys_str_mv |
AT lourencoluisfelipenormandia technicalcostofoperatingapvinstallationasastatcomduringnightime AT lourencoluisfelipenormandia avaliacaodocustotecnicodaoperacaodeumafazendasolarfotovoltaicacomoumstatcomnoperiododanoite |
_version_ |
1719071696159244288 |