Proposed Revisions to Procedures for Testing and Evaluating Radiating Noise Sources from Small Firearms, including the ANSI/ASA S12.42-2010 Procedure

The escalating cost of claims for Noise Induced Hearing Loss (NIHL) in the Canadian Armed Forces (CAF) supports the need to review and upgrade current hearing conservation practices. The rise of these escalating costs and the need to protect the military personnel when training in extreme noise c...

Full description

Bibliographic Details
Main Author: Sarray, Sadreddine
Other Authors: Bouchard, Martin
Format: Others
Language:en
Published: Université d'Ottawa / University of Ottawa 2020
Subjects:
Online Access:http://hdl.handle.net/10393/40549
http://dx.doi.org/10.20381/ruor-24780
id ndltd-uottawa.ca-oai-ruor.uottawa.ca-10393-40549
record_format oai_dc
spelling ndltd-uottawa.ca-oai-ruor.uottawa.ca-10393-405492020-05-28T03:44:51Z Proposed Revisions to Procedures for Testing and Evaluating Radiating Noise Sources from Small Firearms, including the ANSI/ASA S12.42-2010 Procedure Sarray, Sadreddine Bouchard, Martin Noise Induced Hearing Loss Impulse Peak Insertion Loss Bone Conduction Octave Band The escalating cost of claims for Noise Induced Hearing Loss (NIHL) in the Canadian Armed Forces (CAF) supports the need to review and upgrade current hearing conservation practices. The rise of these escalating costs and the need to protect the military personnel when training in extreme noise conditions has initiated an engineering investigation within the Department of National Defence (DND) and in collaboration with the University of Ottawa, to review the existing standards in the field of hearing protection test and evaluation, to propose technical recommendations and to identify the possible technical problems and gaps impacting the quality of the existing procedures. This study dealt with the estimation of the protection capability of Hearing Protection Devices (HPDs) in the case of high-level impulse noise from small firearms weapons that are a particularly damaging source of noise in military environments, representing an important cause of NIHL. Testing and evaluation based on a system engineering approach have been used in this work introducing: - A new testing approach, based on ANSI/ASA S12.42-2010, for testing HPDs when the impulse noise is generated by a small firearm; - A new evaluation approach for HPD performance, introducing a characterization approach using a sub-band analysis for dealing with impulse noise generated by a small firearm. The effectiveness of HPDs, taking into account the physiological human limitations induced by Bone Conduction (BC), is computed by using an innovative method attempting to better prevent the risk of NIHL when using small firearms. 2020-05-26T18:18:06Z 2020-05-26T18:18:06Z 2020-05-26 Thesis http://hdl.handle.net/10393/40549 http://dx.doi.org/10.20381/ruor-24780 en application/pdf Université d'Ottawa / University of Ottawa
collection NDLTD
language en
format Others
sources NDLTD
topic Noise Induced Hearing Loss
Impulse Peak Insertion Loss
Bone Conduction
Octave Band
spellingShingle Noise Induced Hearing Loss
Impulse Peak Insertion Loss
Bone Conduction
Octave Band
Sarray, Sadreddine
Proposed Revisions to Procedures for Testing and Evaluating Radiating Noise Sources from Small Firearms, including the ANSI/ASA S12.42-2010 Procedure
description The escalating cost of claims for Noise Induced Hearing Loss (NIHL) in the Canadian Armed Forces (CAF) supports the need to review and upgrade current hearing conservation practices. The rise of these escalating costs and the need to protect the military personnel when training in extreme noise conditions has initiated an engineering investigation within the Department of National Defence (DND) and in collaboration with the University of Ottawa, to review the existing standards in the field of hearing protection test and evaluation, to propose technical recommendations and to identify the possible technical problems and gaps impacting the quality of the existing procedures. This study dealt with the estimation of the protection capability of Hearing Protection Devices (HPDs) in the case of high-level impulse noise from small firearms weapons that are a particularly damaging source of noise in military environments, representing an important cause of NIHL. Testing and evaluation based on a system engineering approach have been used in this work introducing: - A new testing approach, based on ANSI/ASA S12.42-2010, for testing HPDs when the impulse noise is generated by a small firearm; - A new evaluation approach for HPD performance, introducing a characterization approach using a sub-band analysis for dealing with impulse noise generated by a small firearm. The effectiveness of HPDs, taking into account the physiological human limitations induced by Bone Conduction (BC), is computed by using an innovative method attempting to better prevent the risk of NIHL when using small firearms.
author2 Bouchard, Martin
author_facet Bouchard, Martin
Sarray, Sadreddine
author Sarray, Sadreddine
author_sort Sarray, Sadreddine
title Proposed Revisions to Procedures for Testing and Evaluating Radiating Noise Sources from Small Firearms, including the ANSI/ASA S12.42-2010 Procedure
title_short Proposed Revisions to Procedures for Testing and Evaluating Radiating Noise Sources from Small Firearms, including the ANSI/ASA S12.42-2010 Procedure
title_full Proposed Revisions to Procedures for Testing and Evaluating Radiating Noise Sources from Small Firearms, including the ANSI/ASA S12.42-2010 Procedure
title_fullStr Proposed Revisions to Procedures for Testing and Evaluating Radiating Noise Sources from Small Firearms, including the ANSI/ASA S12.42-2010 Procedure
title_full_unstemmed Proposed Revisions to Procedures for Testing and Evaluating Radiating Noise Sources from Small Firearms, including the ANSI/ASA S12.42-2010 Procedure
title_sort proposed revisions to procedures for testing and evaluating radiating noise sources from small firearms, including the ansi/asa s12.42-2010 procedure
publisher Université d'Ottawa / University of Ottawa
publishDate 2020
url http://hdl.handle.net/10393/40549
http://dx.doi.org/10.20381/ruor-24780
work_keys_str_mv AT sarraysadreddine proposedrevisionstoproceduresfortestingandevaluatingradiatingnoisesourcesfromsmallfirearmsincludingtheansiasas12422010procedure
_version_ 1719315657924804608