Electron density and collision frequency studies using a resonant microwave cavity as a probe

Electron densities and collision frequencies were obtained on a number of gases in a dc discharge at low pressures (0.70-2mm of Hg). These measurements were performed by microwave probing of a filament of the dc discharge placed coaxially in a resonant cavity operating in a TM010 mode. the equipment...

Full description

Bibliographic Details
Main Author: Freeman, Ronald Harold
Format: Others
Language:English
Published: North Texas State University 1973
Subjects:
Online Access:https://digital.library.unt.edu/ark:/67531/metadc699492/
id ndltd-unt.edu-info-ark-67531-metadc699492
record_format oai_dc
spelling ndltd-unt.edu-info-ark-67531-metadc6994922017-08-04T05:18:16Z Electron density and collision frequency studies using a resonant microwave cavity as a probe Freeman, Ronald Harold microwave measurements electric discharges through gases plasma Electron densities and collision frequencies were obtained on a number of gases in a dc discharge at low pressures (0.70-2mm of Hg). These measurements were performed by microwave probing of a filament of the dc discharge placed coaxially in a resonant cavity operating in a TM010 mode. the equipment and techniques for making the microwave measurements employing the resonant cavity are described. North Texas State University 1973-05 Thesis or Dissertation Text local-cont-no: 1002778024-Freeman https://digital.library.unt.edu/ark:/67531/metadc699492/ ark: ark:/67531/metadc699492 English Public ... Copyright Copyright is held by the author, unless otherwise noted. All rights
collection NDLTD
language English
format Others
sources NDLTD
topic microwave measurements
electric discharges through gases
plasma
spellingShingle microwave measurements
electric discharges through gases
plasma
Freeman, Ronald Harold
Electron density and collision frequency studies using a resonant microwave cavity as a probe
description Electron densities and collision frequencies were obtained on a number of gases in a dc discharge at low pressures (0.70-2mm of Hg). These measurements were performed by microwave probing of a filament of the dc discharge placed coaxially in a resonant cavity operating in a TM010 mode. the equipment and techniques for making the microwave measurements employing the resonant cavity are described.
author Freeman, Ronald Harold
author_facet Freeman, Ronald Harold
author_sort Freeman, Ronald Harold
title Electron density and collision frequency studies using a resonant microwave cavity as a probe
title_short Electron density and collision frequency studies using a resonant microwave cavity as a probe
title_full Electron density and collision frequency studies using a resonant microwave cavity as a probe
title_fullStr Electron density and collision frequency studies using a resonant microwave cavity as a probe
title_full_unstemmed Electron density and collision frequency studies using a resonant microwave cavity as a probe
title_sort electron density and collision frequency studies using a resonant microwave cavity as a probe
publisher North Texas State University
publishDate 1973
url https://digital.library.unt.edu/ark:/67531/metadc699492/
work_keys_str_mv AT freemanronaldharold electrondensityandcollisionfrequencystudiesusingaresonantmicrowavecavityasaprobe
_version_ 1718512307086032896