Evaluation of Human Exposure to Magnetic Fields Generated by Electric Power Systems in Complex Configurations

The international growing concern for the human exposure to magnetic fields generated by electric power lines has unavoidably led to imposing legal limits. Respecting these limits, implies being able to calculate easily and accurately the generated magnetic field also in complex configurations. Twis...

Full description

Bibliographic Details
Main Author: Kandia, Effrosyni <1979>
Other Authors: Mazzanti, Giovanni
Format: Doctoral Thesis
Language:en
Published: Alma Mater Studiorum - Università di Bologna 2013
Subjects:
Online Access:http://amsdottorato.unibo.it/6101/
id ndltd-unibo.it-oai-amsdottorato.cib.unibo.it-6101
record_format oai_dc
spelling ndltd-unibo.it-oai-amsdottorato.cib.unibo.it-61012014-03-24T16:30:51Z Evaluation of Human Exposure to Magnetic Fields Generated by Electric Power Systems in Complex Configurations Kandia, Effrosyni <1979> ING-IND/33 Sistemi elettrici per l'energia The international growing concern for the human exposure to magnetic fields generated by electric power lines has unavoidably led to imposing legal limits. Respecting these limits, implies being able to calculate easily and accurately the generated magnetic field also in complex configurations. Twisting of phase conductors is such a case. The consolidated exact and approximated theory regarding a single-circuit twisted three-phase power cable line has been reported along with the proposal of an innovative simplified formula obtained by means of an heuristic procedure. This formula, although being dramatically simpler, is proven to be a good approximation of the analytical formula and at the same time much more accurate than the approximated formula found in literature. The double-circuit twisted three-phase power cable line case has been studied following different approaches of increasing complexity and accuracy. In this framework, the effectiveness of the above-mentioned innovative formula is also examined. The experimental verification of the correctness of the twisted double-circuit theoretical analysis has permitted its extension to multiple-circuit twisted three-phase power cable lines. In addition, appropriate 2D and, in particularly, 3D numerical codes for simulating real existing overhead power lines for the calculation of the magnetic field in their vicinity have been created. Finally, an innovative ‘smart’ measurement and evaluation system of the magnetic field is being proposed, described and validated, which deals with the experimentally-based evaluation of the total magnetic field B generated by multiple sources in complex three-dimensional arrangements, carried out on the basis of the measurement of the three Cartesian field components and their correlation with the field currents via multilinear regression techniques. The ultimate goal is verifying that magnetic induction intensity is within the prescribed limits. Alma Mater Studiorum - Università di Bologna Mazzanti, Giovanni 2013-07-09 Doctoral Thesis PeerReviewed application/pdf en http://amsdottorato.unibo.it/6101/ info:eu-repo/semantics/openAccess
collection NDLTD
language en
format Doctoral Thesis
sources NDLTD
topic ING-IND/33 Sistemi elettrici per l'energia
spellingShingle ING-IND/33 Sistemi elettrici per l'energia
Kandia, Effrosyni <1979>
Evaluation of Human Exposure to Magnetic Fields Generated by Electric Power Systems in Complex Configurations
description The international growing concern for the human exposure to magnetic fields generated by electric power lines has unavoidably led to imposing legal limits. Respecting these limits, implies being able to calculate easily and accurately the generated magnetic field also in complex configurations. Twisting of phase conductors is such a case. The consolidated exact and approximated theory regarding a single-circuit twisted three-phase power cable line has been reported along with the proposal of an innovative simplified formula obtained by means of an heuristic procedure. This formula, although being dramatically simpler, is proven to be a good approximation of the analytical formula and at the same time much more accurate than the approximated formula found in literature. The double-circuit twisted three-phase power cable line case has been studied following different approaches of increasing complexity and accuracy. In this framework, the effectiveness of the above-mentioned innovative formula is also examined. The experimental verification of the correctness of the twisted double-circuit theoretical analysis has permitted its extension to multiple-circuit twisted three-phase power cable lines. In addition, appropriate 2D and, in particularly, 3D numerical codes for simulating real existing overhead power lines for the calculation of the magnetic field in their vicinity have been created. Finally, an innovative ‘smart’ measurement and evaluation system of the magnetic field is being proposed, described and validated, which deals with the experimentally-based evaluation of the total magnetic field B generated by multiple sources in complex three-dimensional arrangements, carried out on the basis of the measurement of the three Cartesian field components and their correlation with the field currents via multilinear regression techniques. The ultimate goal is verifying that magnetic induction intensity is within the prescribed limits.
author2 Mazzanti, Giovanni
author_facet Mazzanti, Giovanni
Kandia, Effrosyni <1979>
author Kandia, Effrosyni <1979>
author_sort Kandia, Effrosyni <1979>
title Evaluation of Human Exposure to Magnetic Fields Generated by Electric Power Systems in Complex Configurations
title_short Evaluation of Human Exposure to Magnetic Fields Generated by Electric Power Systems in Complex Configurations
title_full Evaluation of Human Exposure to Magnetic Fields Generated by Electric Power Systems in Complex Configurations
title_fullStr Evaluation of Human Exposure to Magnetic Fields Generated by Electric Power Systems in Complex Configurations
title_full_unstemmed Evaluation of Human Exposure to Magnetic Fields Generated by Electric Power Systems in Complex Configurations
title_sort evaluation of human exposure to magnetic fields generated by electric power systems in complex configurations
publisher Alma Mater Studiorum - Università di Bologna
publishDate 2013
url http://amsdottorato.unibo.it/6101/
work_keys_str_mv AT kandiaeffrosyni1979 evaluationofhumanexposuretomagneticfieldsgeneratedbyelectricpowersystemsincomplexconfigurations
_version_ 1716654697132064768