Automated Segmentation and Non-Rigid Registration for the Quantitative Evaluation of Myocardial Perfusion from Magnetic Resonance Images
Myocardial perfusion quantification by means of Contrast-Enhanced Cardiac Magnetic Resonance images relies on time consuming frame-by-frame manual tracing of regions of interest. In this Thesis, a novel automated technique for myocardial segmentation and non-rigid registration as a basis for perfusi...
Main Author: | |
---|---|
Other Authors: | |
Format: | Doctoral Thesis |
Language: | en |
Published: |
Alma Mater Studiorum - Università di Bologna
2012
|
Subjects: | |
Online Access: | http://amsdottorato.unibo.it/4850/ |
id |
ndltd-unibo.it-oai-amsdottorato.cib.unibo.it-4850 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-unibo.it-oai-amsdottorato.cib.unibo.it-48502014-03-24T16:30:04Z Automated Segmentation and Non-Rigid Registration for the Quantitative Evaluation of Myocardial Perfusion from Magnetic Resonance Images Tarroni, Giacomo <1983> ING-INF/06 Bioingegneria elettronica e informatica Myocardial perfusion quantification by means of Contrast-Enhanced Cardiac Magnetic Resonance images relies on time consuming frame-by-frame manual tracing of regions of interest. In this Thesis, a novel automated technique for myocardial segmentation and non-rigid registration as a basis for perfusion quantification is presented. The proposed technique is based on three steps: reference frame selection, myocardial segmentation and non-rigid registration. In the first step, the reference frame in which both endo- and epicardial segmentation will be performed is chosen. Endocardial segmentation is achieved by means of a statistical region-based level-set technique followed by a curvature-based regularization motion. Epicardial segmentation is achieved by means of an edge-based level-set technique followed again by a regularization motion. To take into account the changes in position, size and shape of myocardium throughout the sequence due to out of plane respiratory motion, a non-rigid registration algorithm is required. The proposed non-rigid registration scheme consists in a novel multiscale extension of the normalized cross-correlation algorithm in combination with level-set methods. The myocardium is then divided into standard segments. Contrast enhancement curves are computed measuring the mean pixel intensity of each segment over time, and perfusion indices are extracted from each curve. The overall approach has been tested on synthetic and real datasets. For validation purposes, the sequences have been manually traced by an experienced interpreter, and contrast enhancement curves as well as perfusion indices have been computed. Comparisons between automatically extracted and manually obtained contours and enhancement curves showed high inter-technique agreement. Comparisons of perfusion indices computed using both approaches against quantitative coronary angiography and visual interpretation demonstrated that the two technique have similar diagnostic accuracy. In conclusion, the proposed technique allows fast, automated and accurate measurement of intra-myocardial contrast dynamics, and may thus address the strong clinical need for quantitative evaluation of myocardial perfusion. Alma Mater Studiorum - Università di Bologna Lamberti, Claudio 2012-04-20 Doctoral Thesis PeerReviewed application/pdf en http://amsdottorato.unibo.it/4850/ info:eu-repo/semantics/openAccess |
collection |
NDLTD |
language |
en |
format |
Doctoral Thesis |
sources |
NDLTD |
topic |
ING-INF/06 Bioingegneria elettronica e informatica |
spellingShingle |
ING-INF/06 Bioingegneria elettronica e informatica Tarroni, Giacomo <1983> Automated Segmentation and Non-Rigid Registration for the Quantitative Evaluation of Myocardial Perfusion from Magnetic Resonance Images |
description |
Myocardial perfusion quantification by means of Contrast-Enhanced Cardiac Magnetic Resonance images relies on time consuming frame-by-frame manual tracing of regions of interest. In this Thesis, a novel automated technique for myocardial segmentation and non-rigid registration as a basis for perfusion quantification is presented. The proposed technique is based on three steps: reference frame selection, myocardial segmentation and non-rigid registration. In the first step, the reference frame in which both endo- and epicardial segmentation will be performed is chosen. Endocardial segmentation is achieved by means of a statistical region-based level-set technique followed by a curvature-based regularization motion. Epicardial segmentation is achieved by means of an edge-based level-set technique followed again by a regularization motion. To take into account the changes in position, size and shape of myocardium throughout the sequence due to out of plane respiratory motion, a non-rigid registration algorithm is required. The proposed non-rigid registration scheme consists in a novel multiscale extension of the normalized cross-correlation algorithm in combination with level-set methods. The myocardium is then divided into standard segments. Contrast enhancement curves are computed measuring the mean pixel intensity of each segment over time, and perfusion indices are extracted from each curve. The overall approach has been tested on synthetic and real datasets. For validation purposes, the sequences have been manually traced by an experienced interpreter, and contrast enhancement curves as well as perfusion indices have been computed. Comparisons between automatically extracted and manually obtained contours and enhancement curves showed high inter-technique agreement. Comparisons of perfusion indices computed using both approaches against quantitative coronary angiography and visual interpretation demonstrated that the two technique have similar diagnostic accuracy. In conclusion, the proposed technique allows fast, automated and accurate measurement of intra-myocardial contrast dynamics, and may thus address the strong clinical need for quantitative evaluation of myocardial perfusion. |
author2 |
Lamberti, Claudio |
author_facet |
Lamberti, Claudio Tarroni, Giacomo <1983> |
author |
Tarroni, Giacomo <1983> |
author_sort |
Tarroni, Giacomo <1983> |
title |
Automated Segmentation and Non-Rigid Registration for the
Quantitative Evaluation of Myocardial Perfusion from
Magnetic Resonance Images |
title_short |
Automated Segmentation and Non-Rigid Registration for the
Quantitative Evaluation of Myocardial Perfusion from
Magnetic Resonance Images |
title_full |
Automated Segmentation and Non-Rigid Registration for the
Quantitative Evaluation of Myocardial Perfusion from
Magnetic Resonance Images |
title_fullStr |
Automated Segmentation and Non-Rigid Registration for the
Quantitative Evaluation of Myocardial Perfusion from
Magnetic Resonance Images |
title_full_unstemmed |
Automated Segmentation and Non-Rigid Registration for the
Quantitative Evaluation of Myocardial Perfusion from
Magnetic Resonance Images |
title_sort |
automated segmentation and non-rigid registration for the
quantitative evaluation of myocardial perfusion from
magnetic resonance images |
publisher |
Alma Mater Studiorum - Università di Bologna |
publishDate |
2012 |
url |
http://amsdottorato.unibo.it/4850/ |
work_keys_str_mv |
AT tarronigiacomo1983 automatedsegmentationandnonrigidregistrationforthequantitativeevaluationofmyocardialperfusionfrommagneticresonanceimages |
_version_ |
1716654538587373568 |