Development of a Dialysis Graft Based on Tissue Engineering Methods

Despite advancements of modern medicine, the number of patients with the the end-stage kidney disease keeps growing, and surgical procedures to establish and maintain a vascular access for hemodialysis are rising accordingly. Surgical access of choice remains autogenous arteriovenous fistula, wherea...

Full description

Bibliographic Details
Main Author: Radakovic, Dejan
Format: Doctoral Thesis
Language:English
Published: 2020
Subjects:
Online Access:https://opus.bibliothek.uni-wuerzburg.de/frontdoor/index/index/docId/20849
http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-208492
https://nbn-resolving.org/urn:nbn:de:bvb:20-opus-208492
https://opus.bibliothek.uni-wuerzburg.de/files/20849/Radakovic_Dejan_Dissertation.pdf
id ndltd-uni-wuerzburg.de-oai-opus.bibliothek.uni-wuerzburg.de-20849
record_format oai_dc
spelling ndltd-uni-wuerzburg.de-oai-opus.bibliothek.uni-wuerzburg.de-208492020-09-10T17:17:15Z Development of a Dialysis Graft Based on Tissue Engineering Methods Entwicklung einer Dialysegraft basierend auf Tissue Engineering-Methoden Radakovic, Dejan Elektrospinnen Tissue Engineering ddc:610 Despite advancements of modern medicine, the number of patients with the the end-stage kidney disease keeps growing, and surgical procedures to establish and maintain a vascular access for hemodialysis are rising accordingly. Surgical access of choice remains autogenous arteriovenous fistula, whereas approach “fistula first at all costs” leads to failure in certain subgroups of patients. Modern synthetic vascular grafts fail to deliver long-term results comparable with AV fistula. With all that in mind, this work has an aim of developing a new alternative vascular graft, which can be used for hemodialysis access using the methods of TE, especially electrospinning technique. It is hypothesized that electrospun scaffold, made of PCL and collagen type I may assemble mechanical properties similar to native blood vessels. Seeding such electrospun scaffolds with human microvascular endothelial cells (hmvECs) and preconditioning with shear stress and continuous flow might achieve sufficient endothelial lining being able to resist acute thrombosis. One further topic considered on-site infections, which represents one of the most spread complications of dialysis therapy due to continuous needle punctures. The main hypothesis was that during electrospinning process, polymers can be blended with antibiotics with the aim of producing scaffolds with antimicrobial properties, which could lead to reducing the risk of on-site infection on one side, while not affecting the cell viability. Trotz der Fortschritte in der modernen Medizin wächst die Zahl der Patienten mit Nierenerkrankungen im Endstadium weiter, und die chirurgischen Verfahren zur Herstellung und Aufrechterhaltung eines Gefäßzugangs für die Hämodialyse nehmen entsprechend zu. Der chirurgische Zugang der Wahl bleibt eine autogene arteriovenöse Fistel, während der Ansatz „Fistel zuerst um jeden Preis“ bei bestimmten Untergruppen von Patienten zum Versagen führt. Moderne synthetische Gefäßtransplantate liefern keine mit AV-Fisteln vergleichbaren Langzeitergebnisse. Vor diesem Hintergrund zielt diese Arbeit darauf ab, ein neues alternatives Gefäßtransplantat zu entwickeln, das für den Zugang zur Hämodialyse unter Verwendung der TE-Methoden, insbesondere der Elektrospinntechnik, verwendet werden kann. Es wird angenommen, dass ein elektrogesponnenes Gerüst aus PCL und Kollagen Typ I ähnliche mechanische Eigenschaften wie native Blutgefäße aufweisen kann. Die Besiedelung solcher elektrogesponnener Gerüste mit menschlichen mikrovaskulären Endothelzellen (hmvECs) und das Vorkonditionieren mit Scherbeanspruchung und kontinuierlichem Fluss könnte eine ausreichende Endothelialisierung erreichen, um eine akute Thrombose vermeiden zu können. Ein weiteres Thema waren lokale Infektionen, die eine der am weitesten verbreiteten Komplikationen der Dialysetherapie aufgrund kontinuierlicher Nadelstiche darstellen. Die Haupthypothese war, dass Polymere während des Elektrospinnprozesses mit Antibiotika gemischt werden können, um Gerüste mit antimikrobiellen Eigenschaften herzustellen, die dazu führen können, dass das Risiko einer Infektion vor Ort auf einer Seite verringert wird, ohne die Lebensfähigkeit der Zellen zu beeinträchtigen. 2020 doctoralthesis doc-type:doctoralThesis application/pdf https://opus.bibliothek.uni-wuerzburg.de/frontdoor/index/index/docId/20849 urn:nbn:de:bvb:20-opus-208492 https://nbn-resolving.org/urn:nbn:de:bvb:20-opus-208492 https://opus.bibliothek.uni-wuerzburg.de/files/20849/Radakovic_Dejan_Dissertation.pdf eng https://creativecommons.org/licenses/by-sa/4.0/deed.de info:eu-repo/semantics/openAccess
collection NDLTD
language English
format Doctoral Thesis
sources NDLTD
topic Elektrospinnen
Tissue Engineering
ddc:610
spellingShingle Elektrospinnen
Tissue Engineering
ddc:610
Radakovic, Dejan
Development of a Dialysis Graft Based on Tissue Engineering Methods
description Despite advancements of modern medicine, the number of patients with the the end-stage kidney disease keeps growing, and surgical procedures to establish and maintain a vascular access for hemodialysis are rising accordingly. Surgical access of choice remains autogenous arteriovenous fistula, whereas approach “fistula first at all costs” leads to failure in certain subgroups of patients. Modern synthetic vascular grafts fail to deliver long-term results comparable with AV fistula. With all that in mind, this work has an aim of developing a new alternative vascular graft, which can be used for hemodialysis access using the methods of TE, especially electrospinning technique. It is hypothesized that electrospun scaffold, made of PCL and collagen type I may assemble mechanical properties similar to native blood vessels. Seeding such electrospun scaffolds with human microvascular endothelial cells (hmvECs) and preconditioning with shear stress and continuous flow might achieve sufficient endothelial lining being able to resist acute thrombosis. One further topic considered on-site infections, which represents one of the most spread complications of dialysis therapy due to continuous needle punctures. The main hypothesis was that during electrospinning process, polymers can be blended with antibiotics with the aim of producing scaffolds with antimicrobial properties, which could lead to reducing the risk of on-site infection on one side, while not affecting the cell viability. === Trotz der Fortschritte in der modernen Medizin wächst die Zahl der Patienten mit Nierenerkrankungen im Endstadium weiter, und die chirurgischen Verfahren zur Herstellung und Aufrechterhaltung eines Gefäßzugangs für die Hämodialyse nehmen entsprechend zu. Der chirurgische Zugang der Wahl bleibt eine autogene arteriovenöse Fistel, während der Ansatz „Fistel zuerst um jeden Preis“ bei bestimmten Untergruppen von Patienten zum Versagen führt. Moderne synthetische Gefäßtransplantate liefern keine mit AV-Fisteln vergleichbaren Langzeitergebnisse. Vor diesem Hintergrund zielt diese Arbeit darauf ab, ein neues alternatives Gefäßtransplantat zu entwickeln, das für den Zugang zur Hämodialyse unter Verwendung der TE-Methoden, insbesondere der Elektrospinntechnik, verwendet werden kann. Es wird angenommen, dass ein elektrogesponnenes Gerüst aus PCL und Kollagen Typ I ähnliche mechanische Eigenschaften wie native Blutgefäße aufweisen kann. Die Besiedelung solcher elektrogesponnener Gerüste mit menschlichen mikrovaskulären Endothelzellen (hmvECs) und das Vorkonditionieren mit Scherbeanspruchung und kontinuierlichem Fluss könnte eine ausreichende Endothelialisierung erreichen, um eine akute Thrombose vermeiden zu können. Ein weiteres Thema waren lokale Infektionen, die eine der am weitesten verbreiteten Komplikationen der Dialysetherapie aufgrund kontinuierlicher Nadelstiche darstellen. Die Haupthypothese war, dass Polymere während des Elektrospinnprozesses mit Antibiotika gemischt werden können, um Gerüste mit antimikrobiellen Eigenschaften herzustellen, die dazu führen können, dass das Risiko einer Infektion vor Ort auf einer Seite verringert wird, ohne die Lebensfähigkeit der Zellen zu beeinträchtigen.
author Radakovic, Dejan
author_facet Radakovic, Dejan
author_sort Radakovic, Dejan
title Development of a Dialysis Graft Based on Tissue Engineering Methods
title_short Development of a Dialysis Graft Based on Tissue Engineering Methods
title_full Development of a Dialysis Graft Based on Tissue Engineering Methods
title_fullStr Development of a Dialysis Graft Based on Tissue Engineering Methods
title_full_unstemmed Development of a Dialysis Graft Based on Tissue Engineering Methods
title_sort development of a dialysis graft based on tissue engineering methods
publishDate 2020
url https://opus.bibliothek.uni-wuerzburg.de/frontdoor/index/index/docId/20849
http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-208492
https://nbn-resolving.org/urn:nbn:de:bvb:20-opus-208492
https://opus.bibliothek.uni-wuerzburg.de/files/20849/Radakovic_Dejan_Dissertation.pdf
work_keys_str_mv AT radakovicdejan developmentofadialysisgraftbasedontissueengineeringmethods
AT radakovicdejan entwicklungeinerdialysegraftbasierendauftissueengineeringmethoden
_version_ 1719340014726283264