Biomimetic calcium phosphate modification of 3D-printed tissue engineering scaffolds using reactive star-shaped macromers

Biomimetic calcium phosphate (CaP) coatings imitate the trabecular bones surface structure and have shown to promote osteogenic differentiation in multipotent cells. The work of this thesis focused on the problem of former CaP coatings cracking and flaking off when being put on a bendable core struc...

Full description

Bibliographic Details
Main Author: Behets, Jean Nicolas
Format: Doctoral Thesis
Language:English
Published: 2018
Subjects:
Online Access:https://opus.bibliothek.uni-wuerzburg.de/frontdoor/index/index/docId/17172
http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-171728
https://nbn-resolving.org/urn:nbn:de:bvb:20-opus-171728
https://opus.bibliothek.uni-wuerzburg.de/files/17172/Behets_Jean_Nicolas_Dissertation.pdf
id ndltd-uni-wuerzburg.de-oai-opus.bibliothek.uni-wuerzburg.de-17172
record_format oai_dc
collection NDLTD
language English
format Doctoral Thesis
sources NDLTD
topic Tissue engineering
Calcium phosphate
ddc:610
spellingShingle Tissue engineering
Calcium phosphate
ddc:610
Behets, Jean Nicolas
Biomimetic calcium phosphate modification of 3D-printed tissue engineering scaffolds using reactive star-shaped macromers
description Biomimetic calcium phosphate (CaP) coatings imitate the trabecular bones surface structure and have shown to promote osteogenic differentiation in multipotent cells. The work of this thesis focused on the problem of former CaP coatings cracking and flaking off when being put on a bendable core structure like a 3D-printed poly (ε-caprolactone) (PCL) scaffold. The aim was to provide a chemical linkage between PCL and CaP using a star-shaped polymer (sPEG) and a phosphonate, 2-aminoethylphosphonic acid (2-AEP). First, a published CaP coating protocol was revised and investigated in terms of etching parameters for the PCL scaffold. Results presented reproducible thick coatings for all groups. The protocol was then broadened to include subsequent scaffold incubation in sPEG and 2-AEP solutions. Homogenous CaP coatings of decreased thickness presented themselves, proving feasibility. However, as is often found with physical CaP coating depositions, there were some irregular outcomes even during the same experimental group. A lower consumption of the chemical 2-AEP, for economic reasons, meant that the protocol was altered to simultaneously incubate scaffolds with sPEG and 2-AEP including preceding calculations for molar ratios. For ratios 1:1, 1:2 and 1:3, again a homogenous CaP coating was produced on most of the samples, although reproducibility issues maintained. However, the mechanical bending to induce surface cracking showed that the CaP did strongly bond to the sPEG/2-AEP, while the control CaP coating flaked off the surface in large pieces. This research demonstrates that chemically-bound CaP coatings resist flaking off the fiber surface. Future investigations should focus on the mechanisms of CaP crystallization, to improve reproducibility. === Biomimetische Calciumphosphat (CaP) - Beschichtungen imitieren die oberflächliche Struktur des spongiösen Knochens und wirkten sich bereits begünstigend auf die osteogene Differenzierung von multipotenten Zellen aus. Diese Dissertation konzentriert sich auf das Problem des Reißens und Abplatzens bisheriger CaP-Beschichtungen, wenn diese sich auf einem biegsamen Kern-Gerüst, wie einem 3D-gedruckten Polycaprolacton (PCL)-Konstrukt befanden. Das Ziel war, durch den Gebrauch eines sternförmigen Polymers (sPEG) und eines Phosphonates, 2-Aminoethylphosphonsäure (2-AEP), eine chemische Verknüpfung zwischen PCL und CaP herzustellen. Zuerst wurde ein bereits publiziertes CaP-Beschichtungs-Protokoll nachgestellt und verschiedene Ätzungsparameter untersucht. Die Ergebnisse zeigten reproduzierbare, dicke Beschichtungen in allen Gruppen. Danach wurde dieses Protokoll erweitert, indem es nun nacheinander gestellte Inkubationen in sPEG- und 2-AEP-Lösungen mit einbezog. Dünnere, homogene Beschichtungen waren das Ergebnis, was beweist, dass die Hypothese realisierbar ist. Jedoch zeigten die Ergebnisse nicht reproduzierbare Resultate. Desweiteren, war der 2-AEP Verbrauch nicht wirtschaftlich. Daher wurde das Protokoll weiterentwickelt, indem die Proben, nach vorherigen Berechnungen zu den molaren Verhältnissen, simultan mit sPEG und 2-AEP inkubiert wurden. Für die Verhältnisse 1:1, 1:2 und 1:3 wurden wiederum homogene CaP-Beschichtungen produziert. Mit der Absicht Reproduzierbarkeit zu erzielen, wurden weitere Parameter untersucht. Dies blieb jedoch erfolglos. Zuletzt wurde ein mechanischer Test durchgeführt, welcher eine verbesserte CaP-Adhäsion zu den PCL-Fasern nahelegt, wenn diese zuvor mit sPEG und 2-AEP inkubiert wurden. Zukünftige Untersuchungen werden jedoch von Nöten sein, um Daten zur Oberflächenanalyse und von weiteren mechanischen Tests bereitzustellen und um das Protokoll in Bezug auf die Reproduzierbarkeit zu verbessern.
author Behets, Jean Nicolas
author_facet Behets, Jean Nicolas
author_sort Behets, Jean Nicolas
title Biomimetic calcium phosphate modification of 3D-printed tissue engineering scaffolds using reactive star-shaped macromers
title_short Biomimetic calcium phosphate modification of 3D-printed tissue engineering scaffolds using reactive star-shaped macromers
title_full Biomimetic calcium phosphate modification of 3D-printed tissue engineering scaffolds using reactive star-shaped macromers
title_fullStr Biomimetic calcium phosphate modification of 3D-printed tissue engineering scaffolds using reactive star-shaped macromers
title_full_unstemmed Biomimetic calcium phosphate modification of 3D-printed tissue engineering scaffolds using reactive star-shaped macromers
title_sort biomimetic calcium phosphate modification of 3d-printed tissue engineering scaffolds using reactive star-shaped macromers
publishDate 2018
url https://opus.bibliothek.uni-wuerzburg.de/frontdoor/index/index/docId/17172
http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-171728
https://nbn-resolving.org/urn:nbn:de:bvb:20-opus-171728
https://opus.bibliothek.uni-wuerzburg.de/files/17172/Behets_Jean_Nicolas_Dissertation.pdf
work_keys_str_mv AT behetsjeannicolas biomimeticcalciumphosphatemodificationof3dprintedtissueengineeringscaffoldsusingreactivestarshapedmacromers
AT behetsjeannicolas biomimetischecalciumphosphatmodifikationauf3dgedrucktentissueengineeringscaffoldsmitreaktivensternformigenmakromeren
_version_ 1719246537365651456
spelling ndltd-uni-wuerzburg.de-oai-opus.bibliothek.uni-wuerzburg.de-171722019-09-07T16:27:32Z Biomimetic calcium phosphate modification of 3D-printed tissue engineering scaffolds using reactive star-shaped macromers Biomimetische Calcium-Phosphat Modifikation auf 3D-gedruckten tissue engineering Scaffolds mit reaktiven stern-förmigen Makromeren Behets, Jean Nicolas Tissue engineering Calcium phosphate ddc:610 Biomimetic calcium phosphate (CaP) coatings imitate the trabecular bones surface structure and have shown to promote osteogenic differentiation in multipotent cells. The work of this thesis focused on the problem of former CaP coatings cracking and flaking off when being put on a bendable core structure like a 3D-printed poly (ε-caprolactone) (PCL) scaffold. The aim was to provide a chemical linkage between PCL and CaP using a star-shaped polymer (sPEG) and a phosphonate, 2-aminoethylphosphonic acid (2-AEP). First, a published CaP coating protocol was revised and investigated in terms of etching parameters for the PCL scaffold. Results presented reproducible thick coatings for all groups. The protocol was then broadened to include subsequent scaffold incubation in sPEG and 2-AEP solutions. Homogenous CaP coatings of decreased thickness presented themselves, proving feasibility. However, as is often found with physical CaP coating depositions, there were some irregular outcomes even during the same experimental group. A lower consumption of the chemical 2-AEP, for economic reasons, meant that the protocol was altered to simultaneously incubate scaffolds with sPEG and 2-AEP including preceding calculations for molar ratios. For ratios 1:1, 1:2 and 1:3, again a homogenous CaP coating was produced on most of the samples, although reproducibility issues maintained. However, the mechanical bending to induce surface cracking showed that the CaP did strongly bond to the sPEG/2-AEP, while the control CaP coating flaked off the surface in large pieces. This research demonstrates that chemically-bound CaP coatings resist flaking off the fiber surface. Future investigations should focus on the mechanisms of CaP crystallization, to improve reproducibility. Biomimetische Calciumphosphat (CaP) - Beschichtungen imitieren die oberflächliche Struktur des spongiösen Knochens und wirkten sich bereits begünstigend auf die osteogene Differenzierung von multipotenten Zellen aus. Diese Dissertation konzentriert sich auf das Problem des Reißens und Abplatzens bisheriger CaP-Beschichtungen, wenn diese sich auf einem biegsamen Kern-Gerüst, wie einem 3D-gedruckten Polycaprolacton (PCL)-Konstrukt befanden. Das Ziel war, durch den Gebrauch eines sternförmigen Polymers (sPEG) und eines Phosphonates, 2-Aminoethylphosphonsäure (2-AEP), eine chemische Verknüpfung zwischen PCL und CaP herzustellen. Zuerst wurde ein bereits publiziertes CaP-Beschichtungs-Protokoll nachgestellt und verschiedene Ätzungsparameter untersucht. Die Ergebnisse zeigten reproduzierbare, dicke Beschichtungen in allen Gruppen. Danach wurde dieses Protokoll erweitert, indem es nun nacheinander gestellte Inkubationen in sPEG- und 2-AEP-Lösungen mit einbezog. Dünnere, homogene Beschichtungen waren das Ergebnis, was beweist, dass die Hypothese realisierbar ist. Jedoch zeigten die Ergebnisse nicht reproduzierbare Resultate. Desweiteren, war der 2-AEP Verbrauch nicht wirtschaftlich. Daher wurde das Protokoll weiterentwickelt, indem die Proben, nach vorherigen Berechnungen zu den molaren Verhältnissen, simultan mit sPEG und 2-AEP inkubiert wurden. Für die Verhältnisse 1:1, 1:2 und 1:3 wurden wiederum homogene CaP-Beschichtungen produziert. Mit der Absicht Reproduzierbarkeit zu erzielen, wurden weitere Parameter untersucht. Dies blieb jedoch erfolglos. Zuletzt wurde ein mechanischer Test durchgeführt, welcher eine verbesserte CaP-Adhäsion zu den PCL-Fasern nahelegt, wenn diese zuvor mit sPEG und 2-AEP inkubiert wurden. Zukünftige Untersuchungen werden jedoch von Nöten sein, um Daten zur Oberflächenanalyse und von weiteren mechanischen Tests bereitzustellen und um das Protokoll in Bezug auf die Reproduzierbarkeit zu verbessern. 2018 doctoralthesis doc-type:doctoralThesis application/pdf https://opus.bibliothek.uni-wuerzburg.de/frontdoor/index/index/docId/17172 urn:nbn:de:bvb:20-opus-171728 https://nbn-resolving.org/urn:nbn:de:bvb:20-opus-171728 https://opus.bibliothek.uni-wuerzburg.de/files/17172/Behets_Jean_Nicolas_Dissertation.pdf eng https://creativecommons.org/licenses/by-sa/4.0/deed.de info:eu-repo/semantics/openAccess