Contribution to Heat and Mass Transfer for Space Experiments

This manuscript has been realized in the frame of SELENE experiment research activities. SELENE is the ac-ronym of Self-rewetting fluids for ENErgy management and consists of a space project aiming to investigate heat and mass transfer phenomena in mono-groove configuration with self-rewetting fluid...

Full description

Bibliographic Details
Main Author: Tzevelecos, Wassilis
Other Authors: Van Vaerenbergh, Stefan
Format: Doctoral Thesis
Language:en
Published: Universite Libre de Bruxelles 2018
Subjects:
Online Access:https://dipot.ulb.ac.be/dspace/bitstream/2013/269864/4/Table_of_contents_Tzevelecos_Wassilis.pdf
https://dipot.ulb.ac.be/dspace/bitstream/2013/269864/5/PhD_Thesis_full_txt_Tzevelecos_Wassilis.pdf
https://dipot.ulb.ac.be/dspace/bitstream/2013/269864/6/contratWT.pdf
https://dipot.ulb.ac.be/dspace/bitstream/2013/269864/3/PhD_Thesis_Chapter_1_Tzevelecos_Wassilis.pdf
http://hdl.handle.net/2013/ULB-DIPOT:oai:dipot.ulb.ac.be:2013/269864
id ndltd-ulb.ac.be-oai-dipot.ulb.ac.be-2013-269864
record_format oai_dc
collection NDLTD
language en
format Doctoral Thesis
sources NDLTD
topic Sciences de l'ingénieur
SELENE
heat pipes
heat exchange
self-rewetting fluid
microgravity
inverse Marangoni
I-VED
Refractive Profilometry
optical diagnostics
thermal model
spellingShingle Sciences de l'ingénieur
SELENE
heat pipes
heat exchange
self-rewetting fluid
microgravity
inverse Marangoni
I-VED
Refractive Profilometry
optical diagnostics
thermal model
Tzevelecos, Wassilis
Contribution to Heat and Mass Transfer for Space Experiments
description This manuscript has been realized in the frame of SELENE experiment research activities. SELENE is the ac-ronym of Self-rewetting fluids for ENErgy management and consists of a space project aiming to investigate heat and mass transfer phenomena in mono-groove configuration with self-rewetting fluids (SRFs). Self-rewetting fluids are mixture showing an anomalous trend of surface tension with temperature, an inversion of the surface tension slope after certain temperature. As consequence, when the minimum in surface ten-sion is crossed, surface tension gradient at the meniscus interface pulls the liquid towards the warmest region, preventing hot spots. This mechanism is completely spontaneous and has an interesting potential when applied to heat transfer applications as heat pipes (HPs). In HPs heat is removed by the liquid at the warmest region (the evaporator) and transported at the coldest zone (the condenser) by phase change; here, heat is removed by the pipe and dissipated outside through a radiator. To operate correctly, liquid is supplied to the evaporator by capillarity and the liquid vapour is allowed to flow back to condenser from a dedicated pipe region where liquid is not allowed. Vapour condensation releases at the condenser the heat to be dissipated. When SRFs are replacing working fluid in HP applications and temperatures are higher than the characteristic minimum in surface tension, capillary force is assisted by inverse Marangoni flow at the vapour-liquid interface.Since heat pipe performances are related to liquid supplied at the evaporator, in order to compare SRFs and not SRFs working fluids, it is needed to split the contribution of Marangoni and capillary force in the liquid flow. Marangoni effect is related to surface tension gradient that, in a mixture as SRF, is dependent on temperature and local composition at the liquid interface. For all these reasons, SELENE is designed to be the link between scientific research on HPs and heat transfer applications using SRFs. SELENE consists of a mono-groove with trapezoidal section that can be considered as a “clump” of an Inner Grooved Heat Pipe (IGHP) and, in order to split capillary and Marangoni contribution, it is integrated dedicated tools providing the required data in terms of concentration and liquid meniscus shape. Experimental data are used to build a simplified thermo-soluto-fluido dynamic model describing the thermo-mechanic mechanisms between the liquid bulk and the vapour flow. In the manuscript here presented it has been carried on a technology development of the required diag-nostics for the SELENE space project. The diagnostics have been designed to work in microgravity condi-tions even if they are tested on ground. As concentration diagnostic, in the text are proposed several tech-niques and more interest is spent on the adaptation of I-VED (In vivo Embolic Detection) technology meas-uring fluid AC impedance to retrieve composition information; the technology is not yet mature to be inte-grated in SELENE but it presents interesting features to be investigated in microgravity conditions. As me-niscus reconstruction technique it is proposed a new and innovative technology developed in the frame of the presented thesis and it consists of a non-intrusive optical technique aiming to retrieve liquid meniscus shape (and so curvature) from a single visualization window mounted at the top of the SELENE breadboard.An analytical approach aiming to retrieve a simplified mathematical model of the transfer mechanisms is also provided in the text. The analytical analysis clearly shows the relations between the experimental measured data and the velocity profiles in the liquid and vapour regions. In addition, since in SELENE exper-iment the heat conduction across the groove itself is not negligible, in the text it is provided a semi-empirical thermal model based on the Multi Lumped Model (MLM) theory and able to retrieve local heat exchanged information along the pipe length. The model is used to compare experiments with different working fluids at different operational regimes. === Doctorat en Sciences de l'ingénieur et technologie === info:eu-repo/semantics/nonPublished
author2 Van Vaerenbergh, Stefan
author_facet Van Vaerenbergh, Stefan
Tzevelecos, Wassilis
author Tzevelecos, Wassilis
author_sort Tzevelecos, Wassilis
title Contribution to Heat and Mass Transfer for Space Experiments
title_short Contribution to Heat and Mass Transfer for Space Experiments
title_full Contribution to Heat and Mass Transfer for Space Experiments
title_fullStr Contribution to Heat and Mass Transfer for Space Experiments
title_full_unstemmed Contribution to Heat and Mass Transfer for Space Experiments
title_sort contribution to heat and mass transfer for space experiments
publisher Universite Libre de Bruxelles
publishDate 2018
url https://dipot.ulb.ac.be/dspace/bitstream/2013/269864/4/Table_of_contents_Tzevelecos_Wassilis.pdf
https://dipot.ulb.ac.be/dspace/bitstream/2013/269864/5/PhD_Thesis_full_txt_Tzevelecos_Wassilis.pdf
https://dipot.ulb.ac.be/dspace/bitstream/2013/269864/6/contratWT.pdf
https://dipot.ulb.ac.be/dspace/bitstream/2013/269864/3/PhD_Thesis_Chapter_1_Tzevelecos_Wassilis.pdf
http://hdl.handle.net/2013/ULB-DIPOT:oai:dipot.ulb.ac.be:2013/269864
work_keys_str_mv AT tzevelecoswassilis contributiontoheatandmasstransferforspaceexperiments
_version_ 1718967065505693696
spelling ndltd-ulb.ac.be-oai-dipot.ulb.ac.be-2013-2698642019-01-22T05:29:33Z info:eu-repo/semantics/doctoralThesis info:ulb-repo/semantics/doctoralThesis info:ulb-repo/semantics/openurl/vlink-dissertation Contribution to Heat and Mass Transfer for Space Experiments Tzevelecos, Wassilis Van Vaerenbergh, Stefan Delplancke, Marie-Paule Dubois, Frank Savino, Raffaele Carotenuto, Luigi Karapantsios, Thodoris D De Coninck, Joël Universite Libre de Bruxelles Université libre de Bruxelles, Ecole polytechnique de Bruxelles – Chimie et Science des Matériaux, Bruxelles 2018-04-20 en This manuscript has been realized in the frame of SELENE experiment research activities. SELENE is the ac-ronym of Self-rewetting fluids for ENErgy management and consists of a space project aiming to investigate heat and mass transfer phenomena in mono-groove configuration with self-rewetting fluids (SRFs). Self-rewetting fluids are mixture showing an anomalous trend of surface tension with temperature, an inversion of the surface tension slope after certain temperature. As consequence, when the minimum in surface ten-sion is crossed, surface tension gradient at the meniscus interface pulls the liquid towards the warmest region, preventing hot spots. This mechanism is completely spontaneous and has an interesting potential when applied to heat transfer applications as heat pipes (HPs). In HPs heat is removed by the liquid at the warmest region (the evaporator) and transported at the coldest zone (the condenser) by phase change; here, heat is removed by the pipe and dissipated outside through a radiator. To operate correctly, liquid is supplied to the evaporator by capillarity and the liquid vapour is allowed to flow back to condenser from a dedicated pipe region where liquid is not allowed. Vapour condensation releases at the condenser the heat to be dissipated. When SRFs are replacing working fluid in HP applications and temperatures are higher than the characteristic minimum in surface tension, capillary force is assisted by inverse Marangoni flow at the vapour-liquid interface.Since heat pipe performances are related to liquid supplied at the evaporator, in order to compare SRFs and not SRFs working fluids, it is needed to split the contribution of Marangoni and capillary force in the liquid flow. Marangoni effect is related to surface tension gradient that, in a mixture as SRF, is dependent on temperature and local composition at the liquid interface. For all these reasons, SELENE is designed to be the link between scientific research on HPs and heat transfer applications using SRFs. SELENE consists of a mono-groove with trapezoidal section that can be considered as a “clump” of an Inner Grooved Heat Pipe (IGHP) and, in order to split capillary and Marangoni contribution, it is integrated dedicated tools providing the required data in terms of concentration and liquid meniscus shape. Experimental data are used to build a simplified thermo-soluto-fluido dynamic model describing the thermo-mechanic mechanisms between the liquid bulk and the vapour flow. In the manuscript here presented it has been carried on a technology development of the required diag-nostics for the SELENE space project. The diagnostics have been designed to work in microgravity condi-tions even if they are tested on ground. As concentration diagnostic, in the text are proposed several tech-niques and more interest is spent on the adaptation of I-VED (In vivo Embolic Detection) technology meas-uring fluid AC impedance to retrieve composition information; the technology is not yet mature to be inte-grated in SELENE but it presents interesting features to be investigated in microgravity conditions. As me-niscus reconstruction technique it is proposed a new and innovative technology developed in the frame of the presented thesis and it consists of a non-intrusive optical technique aiming to retrieve liquid meniscus shape (and so curvature) from a single visualization window mounted at the top of the SELENE breadboard.An analytical approach aiming to retrieve a simplified mathematical model of the transfer mechanisms is also provided in the text. The analytical analysis clearly shows the relations between the experimental measured data and the velocity profiles in the liquid and vapour regions. In addition, since in SELENE exper-iment the heat conduction across the groove itself is not negligible, in the text it is provided a semi-empirical thermal model based on the Multi Lumped Model (MLM) theory and able to retrieve local heat exchanged information along the pipe length. The model is used to compare experiments with different working fluids at different operational regimes. Sciences de l'ingénieur SELENE heat pipes heat exchange self-rewetting fluid microgravity inverse Marangoni I-VED Refractive Profilometry optical diagnostics thermal model Doctorat en Sciences de l'ingénieur et technologie info:eu-repo/semantics/nonPublished https://dipot.ulb.ac.be/dspace/bitstream/2013/269864/4/Table_of_contents_Tzevelecos_Wassilis.pdf https://dipot.ulb.ac.be/dspace/bitstream/2013/269864/5/PhD_Thesis_full_txt_Tzevelecos_Wassilis.pdf https://dipot.ulb.ac.be/dspace/bitstream/2013/269864/6/contratWT.pdf https://dipot.ulb.ac.be/dspace/bitstream/2013/269864/3/PhD_Thesis_Chapter_1_Tzevelecos_Wassilis.pdf http://hdl.handle.net/2013/ULB-DIPOT:oai:dipot.ulb.ac.be:2013/269864 4 full-text file(s): application/pdf | application/pdf | application/pdf | application/pdf 4 full-text file(s): info:eu-repo/semantics/openAccess | info:eu-repo/semantics/closedAccess | info:eu-repo/semantics/closedAccess | info:eu-repo/semantics/openAccess