A COMPARISON OF BODY COMPOSITION ESTIMATES BETWEEN THE NORLAND DXA, THE IDXA, AND THE BODPOD® IN OVERWEIGHT TO OBESE ADULTS
Background: Body composition measures include fat mass (FM), fat free mass (FFM), and percent body fat (%BF), which are markers of health status and disease risk. Accurate body composition assessment is needed to evaluate an individual’s health and the efficacy of treatment strategies. Objective: Co...
Main Author: | |
---|---|
Format: | Others |
Published: |
UKnowledge
2019
|
Subjects: | |
Online Access: | https://uknowledge.uky.edu/foodsci_etds/66 https://uknowledge.uky.edu/cgi/viewcontent.cgi?article=1072&context=foodsci_etds |
id |
ndltd-uky.edu-oai-uknowledge.uky.edu-foodsci_etds-1072 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-uky.edu-oai-uknowledge.uky.edu-foodsci_etds-10722019-10-16T04:29:24Z A COMPARISON OF BODY COMPOSITION ESTIMATES BETWEEN THE NORLAND DXA, THE IDXA, AND THE BODPOD® IN OVERWEIGHT TO OBESE ADULTS Mason, Jalyn Background: Body composition measures include fat mass (FM), fat free mass (FFM), and percent body fat (%BF), which are markers of health status and disease risk. Accurate body composition assessment is needed to evaluate an individual’s health and the efficacy of treatment strategies. Objective: Compare body composition estimates obtained from the Norland DXA, BodPod®, and iDXA before and after a 12-week exercise intervention. Subjects/setting: Overweight to obese (BMI 25–35 kg/m2) sedentary men and women (n=30) aged 18 to 40 years were recruited from central KY. Main outcome measure: Agreement in FM, FFM, and %BF between Norland DXA, iDXA, and BodPod®. Statistical analysis: Bland Altman plots evaluated mean bias and limits of agreement between iDXA vs Norland DXA, BodPod® vs Norland, and BodPod® vs iDXA. T-tests determined if each mean bias was different from zero. Results: Compared to the iDXA, Norland DXA overestimated BF% and FM at baseline and post intervention (P < 0.01), without differences in FFM (P > 0.05). The BodPod® underestimated BF% and FM and overestimated FFM compared to both DXA machines(all P < 0.01). Conclusion: The Norland and iDXA produce different measures of FM but similar measures of FFM. As well, the BodPod® measures FM and FFM differently than either DXA machine. 2019-01-01T08:00:00Z text application/pdf https://uknowledge.uky.edu/foodsci_etds/66 https://uknowledge.uky.edu/cgi/viewcontent.cgi?article=1072&context=foodsci_etds Theses and Dissertations--Dietetics and Human Nutrition UKnowledge DXA body composition BodPod® Norland iDXA Dietetics and Clinical Nutrition |
collection |
NDLTD |
format |
Others
|
sources |
NDLTD |
topic |
DXA body composition BodPod® Norland iDXA Dietetics and Clinical Nutrition |
spellingShingle |
DXA body composition BodPod® Norland iDXA Dietetics and Clinical Nutrition Mason, Jalyn A COMPARISON OF BODY COMPOSITION ESTIMATES BETWEEN THE NORLAND DXA, THE IDXA, AND THE BODPOD® IN OVERWEIGHT TO OBESE ADULTS |
description |
Background: Body composition measures include fat mass (FM), fat free mass (FFM), and percent body fat (%BF), which are markers of health status and disease risk. Accurate body composition assessment is needed to evaluate an individual’s health and the efficacy of treatment strategies. Objective: Compare body composition estimates obtained from the Norland DXA, BodPod®, and iDXA before and after a 12-week exercise intervention. Subjects/setting: Overweight to obese (BMI 25–35 kg/m2) sedentary men and women (n=30) aged 18 to 40 years were recruited from central KY. Main outcome measure: Agreement in FM, FFM, and %BF between Norland DXA, iDXA, and BodPod®. Statistical analysis: Bland Altman plots evaluated mean bias and limits of agreement between iDXA vs Norland DXA, BodPod® vs Norland, and BodPod® vs iDXA. T-tests determined if each mean bias was different from zero. Results: Compared to the iDXA, Norland DXA overestimated BF% and FM at baseline and post intervention (P < 0.01), without differences in FFM (P > 0.05). The BodPod® underestimated BF% and FM and overestimated FFM compared to both DXA machines(all P < 0.01). Conclusion: The Norland and iDXA produce different measures of FM but similar measures of FFM. As well, the BodPod® measures FM and FFM differently than either DXA machine. |
author |
Mason, Jalyn |
author_facet |
Mason, Jalyn |
author_sort |
Mason, Jalyn |
title |
A COMPARISON OF BODY COMPOSITION ESTIMATES BETWEEN THE NORLAND DXA, THE IDXA, AND THE BODPOD® IN OVERWEIGHT TO OBESE ADULTS |
title_short |
A COMPARISON OF BODY COMPOSITION ESTIMATES BETWEEN THE NORLAND DXA, THE IDXA, AND THE BODPOD® IN OVERWEIGHT TO OBESE ADULTS |
title_full |
A COMPARISON OF BODY COMPOSITION ESTIMATES BETWEEN THE NORLAND DXA, THE IDXA, AND THE BODPOD® IN OVERWEIGHT TO OBESE ADULTS |
title_fullStr |
A COMPARISON OF BODY COMPOSITION ESTIMATES BETWEEN THE NORLAND DXA, THE IDXA, AND THE BODPOD® IN OVERWEIGHT TO OBESE ADULTS |
title_full_unstemmed |
A COMPARISON OF BODY COMPOSITION ESTIMATES BETWEEN THE NORLAND DXA, THE IDXA, AND THE BODPOD® IN OVERWEIGHT TO OBESE ADULTS |
title_sort |
comparison of body composition estimates between the norland dxa, the idxa, and the bodpod® in overweight to obese adults |
publisher |
UKnowledge |
publishDate |
2019 |
url |
https://uknowledge.uky.edu/foodsci_etds/66 https://uknowledge.uky.edu/cgi/viewcontent.cgi?article=1072&context=foodsci_etds |
work_keys_str_mv |
AT masonjalyn acomparisonofbodycompositionestimatesbetweenthenorlanddxatheidxaandthebodpodinoverweighttoobeseadults AT masonjalyn comparisonofbodycompositionestimatesbetweenthenorlanddxatheidxaandthebodpodinoverweighttoobeseadults |
_version_ |
1719269386132389888 |