Multimodal image registration in 2D and 3D correlative microscopy

Cette thèse porte sur la définition d'un schéma de recalage automatique en microscopie corrélative 2D et 3D, en particulier pour des images de microscopie optique et électronique (CLEM). Au cours des dernières années, la CLEM est devenue un outil d'investigation important et puissant dans...

Full description

Bibliographic Details
Main Author: Toledo Acosta, Bertha Mayela
Other Authors: Rennes 1
Language:en
Published: 2018
Subjects:
Online Access:http://www.theses.fr/2018REN1S054/document
id ndltd-theses.fr-2018REN1S054
record_format oai_dc
collection NDLTD
language en
sources NDLTD
topic Recalage multimodal d'images biologiques
Microscopie corrélative
Microscopie optique
Microscopie électronique
Multimodal biological image registration
Correlative microscopy
Light microscopy
Electron microscopy

spellingShingle Recalage multimodal d'images biologiques
Microscopie corrélative
Microscopie optique
Microscopie électronique
Multimodal biological image registration
Correlative microscopy
Light microscopy
Electron microscopy

Toledo Acosta, Bertha Mayela
Multimodal image registration in 2D and 3D correlative microscopy
description Cette thèse porte sur la définition d'un schéma de recalage automatique en microscopie corrélative 2D et 3D, en particulier pour des images de microscopie optique et électronique (CLEM). Au cours des dernières années, la CLEM est devenue un outil d'investigation important et puissant dans le domaine de la bio-imagerie. En utilisant la CLEM, des informations complémentaires peuvent être collectées à partir d'un échantillon biologique. La superposition des différentes images microscopiques est généralement réalisée à l'aide de techniques impliquant une assistance manuelle à plusieurs étapes, ce qui est exigeant et prend beaucoup de temps pour les biologistes. Pour faciliter et diffuser le procédé de CLEM, notre travail de thèse est axé sur la création de méthodes de recalage automatique qui soient fiables, faciles à utiliser et qui ne nécessitent pas d'ajustement de paramètres ou de connaissances complexes. Le recalage CLEM doit faire face à de nombreux problèmes dus aux différences entre les images de microscopie électronique et optique et leur mode d'acquisition, tant en termes de résolution du pixel, de taille des images, de contenu, de champ de vision et d'apparence. Nous avons conçu des méthodes basées sur l'intensité des images pour aligner les images CLEM en 2D et 3D. Elles comprennent plusieurs étapes : représentation commune des images LM et EM à l'aide de la transformation LoG, pré-alignement exploitant des mesures de similarité à partir d'histogrammes avec une recherche exhaustive, et un recalage fin basé sur l'information mutuelle. De plus, nous avons défini une méthode de sélection robuste de modèles de mouvement, et un méthode de détection multi-échelle de spots, que nous avons exploitées dans le recalage CLEM 2D. Notre schéma de recalage automatisé pour la CLEM a été testé avec succès sur plusieurs ensembles de données CLEM réelles 2D et 3D. Les résultats ont été validés par des biologistes, offrant une excellente perspective sur l'utilité de nos développements. === This thesis is concerned with the definition of an automated registration framework for 2D and 3D correlative microscopy images, in particular for correlative light and electron microscopy (CLEM) images. In recent years, CLEM has become an important and powerful tool in the bioimaging field. By using CLEM, complementary information can be collected from a biological sample. An overlay of the different microscopy images is commonly achieved using techniques involving manual assistance at several steps, which is demanding and time consuming for biologists. To facilitate and disseminate the CLEM process for biologists, the thesis work is focused on creating automatic registration methods that are reliable, easy to use and do not require parameter tuning or complex knowledge. CLEM registration has to deal with many issues due to the differences between electron microscopy and light microscopy images and their acquisition, both in terms of pixel resolution, image size, content, field of view and appearance. We have designed intensity-based methods to align CLEM images in 2D and 3D. They involved a common representation of the LM and EM images using the LoG transform, a pre-alignment step exploiting histogram-based similarities within an exhaustive search, and a fine mutual information-based registration. In addition, we have defined a robust motion model selection method, and a multiscale spot detection method which were exploited in the 2D CLEM registration. Our automated CLEM registration framework was successfully tested on several real 2D and 3D CLEM datasets and the results were validated by biologists, offering an excellent perspective in the usefulness of our methods.
author2 Rennes 1
author_facet Rennes 1
Toledo Acosta, Bertha Mayela
author Toledo Acosta, Bertha Mayela
author_sort Toledo Acosta, Bertha Mayela
title Multimodal image registration in 2D and 3D correlative microscopy
title_short Multimodal image registration in 2D and 3D correlative microscopy
title_full Multimodal image registration in 2D and 3D correlative microscopy
title_fullStr Multimodal image registration in 2D and 3D correlative microscopy
title_full_unstemmed Multimodal image registration in 2D and 3D correlative microscopy
title_sort multimodal image registration in 2d and 3d correlative microscopy
publishDate 2018
url http://www.theses.fr/2018REN1S054/document
work_keys_str_mv AT toledoacostaberthamayela multimodalimageregistrationin2dand3dcorrelativemicroscopy
AT toledoacostaberthamayela recalagedimagesmultimodalesenmicroscopiecorrelative2det3d
_version_ 1719302938959020032
spelling ndltd-theses.fr-2018REN1S0542019-12-11T15:22:58Z Multimodal image registration in 2D and 3D correlative microscopy Recalage d'images multimodales en microscopie corrélative 2D et 3D Recalage multimodal d'images biologiques Microscopie corrélative Microscopie optique Microscopie électronique Multimodal biological image registration Correlative microscopy Light microscopy Electron microscopy Cette thèse porte sur la définition d'un schéma de recalage automatique en microscopie corrélative 2D et 3D, en particulier pour des images de microscopie optique et électronique (CLEM). Au cours des dernières années, la CLEM est devenue un outil d'investigation important et puissant dans le domaine de la bio-imagerie. En utilisant la CLEM, des informations complémentaires peuvent être collectées à partir d'un échantillon biologique. La superposition des différentes images microscopiques est généralement réalisée à l'aide de techniques impliquant une assistance manuelle à plusieurs étapes, ce qui est exigeant et prend beaucoup de temps pour les biologistes. Pour faciliter et diffuser le procédé de CLEM, notre travail de thèse est axé sur la création de méthodes de recalage automatique qui soient fiables, faciles à utiliser et qui ne nécessitent pas d'ajustement de paramètres ou de connaissances complexes. Le recalage CLEM doit faire face à de nombreux problèmes dus aux différences entre les images de microscopie électronique et optique et leur mode d'acquisition, tant en termes de résolution du pixel, de taille des images, de contenu, de champ de vision et d'apparence. Nous avons conçu des méthodes basées sur l'intensité des images pour aligner les images CLEM en 2D et 3D. Elles comprennent plusieurs étapes : représentation commune des images LM et EM à l'aide de la transformation LoG, pré-alignement exploitant des mesures de similarité à partir d'histogrammes avec une recherche exhaustive, et un recalage fin basé sur l'information mutuelle. De plus, nous avons défini une méthode de sélection robuste de modèles de mouvement, et un méthode de détection multi-échelle de spots, que nous avons exploitées dans le recalage CLEM 2D. Notre schéma de recalage automatisé pour la CLEM a été testé avec succès sur plusieurs ensembles de données CLEM réelles 2D et 3D. Les résultats ont été validés par des biologistes, offrant une excellente perspective sur l'utilité de nos développements. This thesis is concerned with the definition of an automated registration framework for 2D and 3D correlative microscopy images, in particular for correlative light and electron microscopy (CLEM) images. In recent years, CLEM has become an important and powerful tool in the bioimaging field. By using CLEM, complementary information can be collected from a biological sample. An overlay of the different microscopy images is commonly achieved using techniques involving manual assistance at several steps, which is demanding and time consuming for biologists. To facilitate and disseminate the CLEM process for biologists, the thesis work is focused on creating automatic registration methods that are reliable, easy to use and do not require parameter tuning or complex knowledge. CLEM registration has to deal with many issues due to the differences between electron microscopy and light microscopy images and their acquisition, both in terms of pixel resolution, image size, content, field of view and appearance. We have designed intensity-based methods to align CLEM images in 2D and 3D. They involved a common representation of the LM and EM images using the LoG transform, a pre-alignment step exploiting histogram-based similarities within an exhaustive search, and a fine mutual information-based registration. In addition, we have defined a robust motion model selection method, and a multiscale spot detection method which were exploited in the 2D CLEM registration. Our automated CLEM registration framework was successfully tested on several real 2D and 3D CLEM datasets and the results were validated by biologists, offering an excellent perspective in the usefulness of our methods. Electronic Thesis or Dissertation Text en http://www.theses.fr/2018REN1S054/document Toledo Acosta, Bertha Mayela 2018-05-23 Rennes 1 Bouthémy, Patrick