Total variational optical flow for robust and accurate bladder image mosaicing

La cystoscopie est l’examen de référence pour le diagnostic et le traitement du cancer de la vessie. Le champ de vue (CdV) réduit des endoscopes complique le diagnostic et le suivi des lésions. Les mosaïques d’images sont une solution à ce problème car elles visualisent des CdV étendus. Toutefois, p...

Full description

Bibliographic Details
Main Author: Ali, Sharib
Other Authors: Université de Lorraine
Language:en
Published: 2016
Subjects:
Online Access:http://www.theses.fr/2016LORR0006/document
id ndltd-theses.fr-2016LORR0006
record_format oai_dc
collection NDLTD
language en
sources NDLTD
topic Approches variationnelles totales
Flot optique
Constance de structure
Descripteurs de voisinages
Régularisation anisotropique
Mosaïquage d'images endoscopiques
Total variational approach
Optical flow
Structure constancy
Neighbordood descriptors
Anistropic regularization
Convex optimization
Endoscopic image mosaicing
621.367
006.6
spellingShingle Approches variationnelles totales
Flot optique
Constance de structure
Descripteurs de voisinages
Régularisation anisotropique
Mosaïquage d'images endoscopiques
Total variational approach
Optical flow
Structure constancy
Neighbordood descriptors
Anistropic regularization
Convex optimization
Endoscopic image mosaicing
621.367
006.6
Ali, Sharib
Total variational optical flow for robust and accurate bladder image mosaicing
description La cystoscopie est l’examen de référence pour le diagnostic et le traitement du cancer de la vessie. Le champ de vue (CdV) réduit des endoscopes complique le diagnostic et le suivi des lésions. Les mosaïques d’images sont une solution à ce problème car elles visualisent des CdV étendus. Toutefois, pour la vessie, le mosaïque d’images est un véritable défi à cause du faible contraste dans les images, des textures peu prononcées, de la variabilité intra- et inter-patient et des changements d’illumination dans les séquences. Ce défi est également à relever dans d’autres modalités endoscopiques ou dans des scènes non médicales comme les vidéos sous-marines. Dans cette thèse, une énergie variationnelle totale a d’abord été minimisée à l’aide d’un algorithme primal-dual du premier ordre pour obtenir un flot optique fournissant une correspondance dense et précise entre les points homologues des paires d’images. Les correspondances sont ensuite utilisées pour déterminer les paramètres des transformations requises pour le placement des images dans le repère global de la mosaïque. Les méthodes proposées pour l’estimation du flot optique dense incluent un terme d’attache aux données qui minimise le nombre des vecteurs aberrants et un terme de régularisation conçu pour préserver les discontinuités du champ devecteurs. Un algorithme de flot optique qui est robuste vis-à-vis de changements d’illumination importants (et utilisable pour différentes modalités) a également été développé dans ce contexte. La précision et la robustesse des méthodes de recalage proposées ont été testées sur des jeux de données (de flot optique) publiquement accessibles et sur des fantômes de vessies et de la peau. Des résultats sur des données patients acquises avec des cystoscopes rigides et flexibles, en lumière blanche ou en fluorescence, montrent la robustesse des algorithmes proposés. Ces résultats sont complétés par ceux obtenus pour d’autres séquences endoscopiques réelles de dermatoscopie, de scène sous-marine et de données d’exploration spatiale. === Cystoscopy is the reference procedure for the diagnosis and treatment of bladder cancer. The small field of view (FOV) of endoscopes makes both the diagnosis and follow-up of lesions difficult. Image mosaics are a solution to this problem since they visualize large FOVs of the bladder scene. However, due to low contrast, weak texture, inter- and intra-patient texture variability and illumination changes in these image sequences, the task of image mosaicing becomes challenging. This is also a major concern in other endoscopic data and non-medical scenes like underwater videos. In this thesis, a total variational energy has been first minimized using a first-order primal-dual algorithm in convex optimization to obtain optical flow vector fields giving a dense and accurate correspondence between homologous points of the image pairs. The correspondences are then used to obtain transformation parameters for registering the images to one global mosaic coordinate system. The proposed methods for dense optical flow estimation include a data-term which is modeled to minimize at most the outliers and a regularizer which is designed to preserve at their best the flow field discontinuities. An optical flow algorithm, which is robust to strong illumination changes (and which suits to different modalities), has also been developed in this framework. The registration accuracy and robustness of the proposed methods are tested on both publicly available datasets for optical flow estimation and on simulated bladder and skin phantoms. Results on patient data acquired with rigid and flexible cystoscopes under the white light and the fluorescence modality show the robustness of the proposed approaches. These results are also complemented with those of other real endoscopic data, dermoscopic sequences, underwater scenes and space exploration data.
author2 Université de Lorraine
author_facet Université de Lorraine
Ali, Sharib
author Ali, Sharib
author_sort Ali, Sharib
title Total variational optical flow for robust and accurate bladder image mosaicing
title_short Total variational optical flow for robust and accurate bladder image mosaicing
title_full Total variational optical flow for robust and accurate bladder image mosaicing
title_fullStr Total variational optical flow for robust and accurate bladder image mosaicing
title_full_unstemmed Total variational optical flow for robust and accurate bladder image mosaicing
title_sort total variational optical flow for robust and accurate bladder image mosaicing
publishDate 2016
url http://www.theses.fr/2016LORR0006/document
work_keys_str_mv AT alisharib totalvariationalopticalflowforrobustandaccuratebladderimagemosaicing
AT alisharib calculduflotoptiquedansuneapprochevariationnelletotalepourlemosaiquagerobusteetprecisdimagesdelavessie
_version_ 1719192360876769280
spelling ndltd-theses.fr-2016LORR00062019-05-24T03:32:59Z Total variational optical flow for robust and accurate bladder image mosaicing Calcul du flot optique dans une approche variationnelle totale pour le mosaïquage robuste et précis d’images de la vessie Approches variationnelles totales Flot optique Constance de structure Descripteurs de voisinages Régularisation anisotropique Mosaïquage d'images endoscopiques Total variational approach Optical flow Structure constancy Neighbordood descriptors Anistropic regularization Convex optimization Endoscopic image mosaicing 621.367 006.6 La cystoscopie est l’examen de référence pour le diagnostic et le traitement du cancer de la vessie. Le champ de vue (CdV) réduit des endoscopes complique le diagnostic et le suivi des lésions. Les mosaïques d’images sont une solution à ce problème car elles visualisent des CdV étendus. Toutefois, pour la vessie, le mosaïque d’images est un véritable défi à cause du faible contraste dans les images, des textures peu prononcées, de la variabilité intra- et inter-patient et des changements d’illumination dans les séquences. Ce défi est également à relever dans d’autres modalités endoscopiques ou dans des scènes non médicales comme les vidéos sous-marines. Dans cette thèse, une énergie variationnelle totale a d’abord été minimisée à l’aide d’un algorithme primal-dual du premier ordre pour obtenir un flot optique fournissant une correspondance dense et précise entre les points homologues des paires d’images. Les correspondances sont ensuite utilisées pour déterminer les paramètres des transformations requises pour le placement des images dans le repère global de la mosaïque. Les méthodes proposées pour l’estimation du flot optique dense incluent un terme d’attache aux données qui minimise le nombre des vecteurs aberrants et un terme de régularisation conçu pour préserver les discontinuités du champ devecteurs. Un algorithme de flot optique qui est robuste vis-à-vis de changements d’illumination importants (et utilisable pour différentes modalités) a également été développé dans ce contexte. La précision et la robustesse des méthodes de recalage proposées ont été testées sur des jeux de données (de flot optique) publiquement accessibles et sur des fantômes de vessies et de la peau. Des résultats sur des données patients acquises avec des cystoscopes rigides et flexibles, en lumière blanche ou en fluorescence, montrent la robustesse des algorithmes proposés. Ces résultats sont complétés par ceux obtenus pour d’autres séquences endoscopiques réelles de dermatoscopie, de scène sous-marine et de données d’exploration spatiale. Cystoscopy is the reference procedure for the diagnosis and treatment of bladder cancer. The small field of view (FOV) of endoscopes makes both the diagnosis and follow-up of lesions difficult. Image mosaics are a solution to this problem since they visualize large FOVs of the bladder scene. However, due to low contrast, weak texture, inter- and intra-patient texture variability and illumination changes in these image sequences, the task of image mosaicing becomes challenging. This is also a major concern in other endoscopic data and non-medical scenes like underwater videos. In this thesis, a total variational energy has been first minimized using a first-order primal-dual algorithm in convex optimization to obtain optical flow vector fields giving a dense and accurate correspondence between homologous points of the image pairs. The correspondences are then used to obtain transformation parameters for registering the images to one global mosaic coordinate system. The proposed methods for dense optical flow estimation include a data-term which is modeled to minimize at most the outliers and a regularizer which is designed to preserve at their best the flow field discontinuities. An optical flow algorithm, which is robust to strong illumination changes (and which suits to different modalities), has also been developed in this framework. The registration accuracy and robustness of the proposed methods are tested on both publicly available datasets for optical flow estimation and on simulated bladder and skin phantoms. Results on patient data acquired with rigid and flexible cystoscopes under the white light and the fluorescence modality show the robustness of the proposed approaches. These results are also complemented with those of other real endoscopic data, dermoscopic sequences, underwater scenes and space exploration data. Electronic Thesis or Dissertation Text en http://www.theses.fr/2016LORR0006/document Ali, Sharib 2016-01-04 Université de Lorraine Daul, Christian Blondel, Walter