A Process Analytical Technology (PAT) approach involving near infrared spectroscopy to control the manufacturing of an active pharmaceutical ingredient : development, validation and implementation
Les entreprises pharmaceutiques ont progressivement adopté le concept de Process Analytical Technology (PAT) afin de contrôler et d'assurer en temps réel la qualité des produits pharmaceutiques au cours de leur production. Le PAT et un composant central du concept plus général de Quality-by-Des...
Main Author: | |
---|---|
Other Authors: | |
Language: | en |
Published: |
2013
|
Subjects: | |
Online Access: | http://www.theses.fr/2013AIXM4375 |
id |
ndltd-theses.fr-2013AIXM4375 |
---|---|
record_format |
oai_dc |
collection |
NDLTD |
language |
en |
sources |
NDLTD |
topic |
Process Analytical Technology (PAT) Quality-by-Design (QbD) Spectroscopie proche infrarouge (PIR) Analyse en ligne Cristallisation de principe actif pharmaceutique Validation de méthode Process Analytical Technology (PAT) Quality-by-Design (QbD) Near infrared (NIR) spectroscopy On-line analysis Active pharmaceutical ingredient (API) crystallization Method validation |
spellingShingle |
Process Analytical Technology (PAT) Quality-by-Design (QbD) Spectroscopie proche infrarouge (PIR) Analyse en ligne Cristallisation de principe actif pharmaceutique Validation de méthode Process Analytical Technology (PAT) Quality-by-Design (QbD) Near infrared (NIR) spectroscopy On-line analysis Active pharmaceutical ingredient (API) crystallization Method validation Schaefer, Cédric A Process Analytical Technology (PAT) approach involving near infrared spectroscopy to control the manufacturing of an active pharmaceutical ingredient : development, validation and implementation |
description |
Les entreprises pharmaceutiques ont progressivement adopté le concept de Process Analytical Technology (PAT) afin de contrôler et d'assurer en temps réel la qualité des produits pharmaceutiques au cours de leur production. Le PAT et un composant central du concept plus général de Quality-by-Design (QbD) promu par les agence régulatrices et visant à construire la qualité des produits via une approche scientifique et la gestion des risques.Une méthode basée sur la spectroscopie proche infrarouge (PIR) a été développée comme un outil du PAT pour contrôler en ligne la cristallisation d'un principe actif pharmaceutique. Au cours du procédé les teneurs en principe actif et en solvant résiduel doivent être déterminées avec précision afin d'atteindre un point d'ensemencement prédéfini. Une méthodologie basée sur les principes du QbD a guidé le développement et la validation de la méthode tout en assurant l'adéquation avec son utilisation prévue. Des modèles basés sur les moindres carrés partiels ont été construits à l'aide d'outils chimiométriques afin de quantifier les 2 analytes d'intérêt. La méthode a été totalement validée conformément aux requis officiels en utilisant les profils d'exactitude. Un suivi du procédé en temps réel a permis de prouver que la méthode correspond à son usage prévu.L'implémentation de cette méthode comme à l'échelle industrielle au lancement de ce nouveau procédé permettra le contrôle automatique de l'étape de cristallisation dans le but d'assurer un niveau de qualité prédéfini de l'API. D'autres avantages sont attendus incluant la réduction du temps du procédé, la suppression d'un échantillonnage difficile et d'analyses hors ligne fastidieuses. === Pharmaceutical companies are progressively adopting and introducing the Process Analytical Technology (PAT) concept to control and ensure in real-time product quality in development and manufacturing. PAT is a key component of the Quality-by-Design (QbD) framework promoted by the regulatory authorities, aiming the building of product quality based on both a strong scientific background and a quality risk management approach.An analytical method based on near infrared (NIR) spectroscopy was developed as a PAT tool to control on-line an API (active pharmaceutical ingredient) crystallization. During this process the API and residual solvent contents need to be precisely determined to reach a predefined seeding point. An original methodology based on the QbD principles was applied to conduct the development and validation of the NIR method and to ensure that it is fitted for its intended use. Partial least squares (PLS) models were developed and optimized through chemometrics tools in order to quantify the 2 analytes of interest. The method was fully validated according to the official requirements using the accuracy profile approach. Besides, a real-time process monitoring was added to the validation phase to prove and document that the method is fitted for purpose.Implementation of this method as an in-process control at industrial plant from the launch of this new pharmaceutical process will enable automatic control of the crystallization step in order to ensure a predefined quality level of the API. Other valuable benefits are expected such as reduction of the process time, and suppression of a difficult sampling and tedious off-line analyzes. |
author2 |
Aix-Marseille |
author_facet |
Aix-Marseille Schaefer, Cédric |
author |
Schaefer, Cédric |
author_sort |
Schaefer, Cédric |
title |
A Process Analytical Technology (PAT) approach involving near infrared spectroscopy to control the manufacturing of an active pharmaceutical ingredient : development, validation and implementation |
title_short |
A Process Analytical Technology (PAT) approach involving near infrared spectroscopy to control the manufacturing of an active pharmaceutical ingredient : development, validation and implementation |
title_full |
A Process Analytical Technology (PAT) approach involving near infrared spectroscopy to control the manufacturing of an active pharmaceutical ingredient : development, validation and implementation |
title_fullStr |
A Process Analytical Technology (PAT) approach involving near infrared spectroscopy to control the manufacturing of an active pharmaceutical ingredient : development, validation and implementation |
title_full_unstemmed |
A Process Analytical Technology (PAT) approach involving near infrared spectroscopy to control the manufacturing of an active pharmaceutical ingredient : development, validation and implementation |
title_sort |
process analytical technology (pat) approach involving near infrared spectroscopy to control the manufacturing of an active pharmaceutical ingredient : development, validation and implementation |
publishDate |
2013 |
url |
http://www.theses.fr/2013AIXM4375 |
work_keys_str_mv |
AT schaefercedric aprocessanalyticaltechnologypatapproachinvolvingnearinfraredspectroscopytocontrolthemanufacturingofanactivepharmaceuticalingredientdevelopmentvalidationandimplementation AT schaefercedric processanalyticaltechnologypatapproachinvolvingnearinfraredspectroscopytocontrolthemanufacturingofanactivepharmaceuticalingredientdevelopmentvalidationandimplementation |
_version_ |
1718483570917376000 |
spelling |
ndltd-theses.fr-2013AIXM43752017-06-30T04:43:33Z A Process Analytical Technology (PAT) approach involving near infrared spectroscopy to control the manufacturing of an active pharmaceutical ingredient : development, validation and implementation Process Analytical Technology (PAT) Quality-by-Design (QbD) Spectroscopie proche infrarouge (PIR) Analyse en ligne Cristallisation de principe actif pharmaceutique Validation de méthode Process Analytical Technology (PAT) Quality-by-Design (QbD) Near infrared (NIR) spectroscopy On-line analysis Active pharmaceutical ingredient (API) crystallization Method validation Les entreprises pharmaceutiques ont progressivement adopté le concept de Process Analytical Technology (PAT) afin de contrôler et d'assurer en temps réel la qualité des produits pharmaceutiques au cours de leur production. Le PAT et un composant central du concept plus général de Quality-by-Design (QbD) promu par les agence régulatrices et visant à construire la qualité des produits via une approche scientifique et la gestion des risques.Une méthode basée sur la spectroscopie proche infrarouge (PIR) a été développée comme un outil du PAT pour contrôler en ligne la cristallisation d'un principe actif pharmaceutique. Au cours du procédé les teneurs en principe actif et en solvant résiduel doivent être déterminées avec précision afin d'atteindre un point d'ensemencement prédéfini. Une méthodologie basée sur les principes du QbD a guidé le développement et la validation de la méthode tout en assurant l'adéquation avec son utilisation prévue. Des modèles basés sur les moindres carrés partiels ont été construits à l'aide d'outils chimiométriques afin de quantifier les 2 analytes d'intérêt. La méthode a été totalement validée conformément aux requis officiels en utilisant les profils d'exactitude. Un suivi du procédé en temps réel a permis de prouver que la méthode correspond à son usage prévu.L'implémentation de cette méthode comme à l'échelle industrielle au lancement de ce nouveau procédé permettra le contrôle automatique de l'étape de cristallisation dans le but d'assurer un niveau de qualité prédéfini de l'API. D'autres avantages sont attendus incluant la réduction du temps du procédé, la suppression d'un échantillonnage difficile et d'analyses hors ligne fastidieuses. Pharmaceutical companies are progressively adopting and introducing the Process Analytical Technology (PAT) concept to control and ensure in real-time product quality in development and manufacturing. PAT is a key component of the Quality-by-Design (QbD) framework promoted by the regulatory authorities, aiming the building of product quality based on both a strong scientific background and a quality risk management approach.An analytical method based on near infrared (NIR) spectroscopy was developed as a PAT tool to control on-line an API (active pharmaceutical ingredient) crystallization. During this process the API and residual solvent contents need to be precisely determined to reach a predefined seeding point. An original methodology based on the QbD principles was applied to conduct the development and validation of the NIR method and to ensure that it is fitted for its intended use. Partial least squares (PLS) models were developed and optimized through chemometrics tools in order to quantify the 2 analytes of interest. The method was fully validated according to the official requirements using the accuracy profile approach. Besides, a real-time process monitoring was added to the validation phase to prove and document that the method is fitted for purpose.Implementation of this method as an in-process control at industrial plant from the launch of this new pharmaceutical process will enable automatic control of the crystallization step in order to ensure a predefined quality level of the API. Other valuable benefits are expected such as reduction of the process time, and suppression of a difficult sampling and tedious off-line analyzes. Electronic Thesis or Dissertation Text en http://www.theses.fr/2013AIXM4375 Schaefer, Cédric 2013-07-11 Aix-Marseille Fotiadu, Fréderic |