Characterization of wound monitoring systems used to quantify and locate plutonium contamination

When an accident involving the possibility of a plutonium contaminated wound occurs, the contamination is often quantified using sodium iodide (NaI(Tl)) and high purity germanium (HPGe) detection systems. The NaI(Tl) system is used to quantify the amount of contamination, while HPGe is used to gauge...

Full description

Bibliographic Details
Main Author: Dimmerling, Paul James
Other Authors: Braby, Leslie A.
Format: Others
Language:en_US
Published: 2010
Subjects:
Online Access:http://hdl.handle.net/1969.1/ETD-TAMU-2524
http://hdl.handle.net/1969.1/ETD-TAMU-2524
id ndltd-tamu.edu-oai-repository.tamu.edu-1969.1-ETD-TAMU-2524
record_format oai_dc
spelling ndltd-tamu.edu-oai-repository.tamu.edu-1969.1-ETD-TAMU-25242013-01-08T10:39:41ZCharacterization of wound monitoring systems used to quantify and locate plutonium contaminationDimmerling, Paul JamesPlutoniumwoundNaI(Tl)HPGecontaminationLANLWhen an accident involving the possibility of a plutonium contaminated wound occurs, the contamination is often quantified using sodium iodide (NaI(Tl)) and high purity germanium (HPGe) detection systems. The NaI(Tl) system is used to quantify the amount of contamination, while HPGe is used to gauge the depth of contamination in the wound. Assessment of plutonium contaminated wounds is difficult due to the lowenergy and yield of the uranium L-shell x rays used for the measurement, which can be effected by source distance, shape, and tissue attenuation. These effects on wound counting systems used at Los Alamos National Laboratory (LANL) were characterized experimentally using common source shapes (disk, point, and line) and acrylic plastic as a tissue substitute. Experiments were conducted to characterize detector responses as a function of tissue attenuation, source distance, and source depth in tissue. The computer code MCNP5 was used to model both systems for wound counting and better examine angular displacement of a line source in tissue. The NaI(Tl) detector response was characterized using absolute detector efficiency for all experimental measurements. Measurements showed that the NaI(Tl) system is significantly effected by the source to detector position and depth in tissue. Characterization of the HPGe detection system was done utilizing the peak-to-peak ratio from the two low-energy x rays. HPGe peak-to-peak ratios were not affected by source to detector distance, but showed an increased response to source depth in tissue. MCNP results suggested that small incident angles from the plane of the detector face can cause significant effects on the response of both detectors. In summary, the response of both systems showed dependence on source geometry and depth of contamination in tissue. Correction values and uncertainties were determined based on these dependencies.Braby, Leslie A.2010-01-15T00:11:33Z2010-01-16T00:38:52Z2010-01-15T00:11:33Z2010-01-16T00:38:52Z2007-122009-05-15BookThesisElectronic Thesistextelectronicapplication/pdfborn digitalhttp://hdl.handle.net/1969.1/ETD-TAMU-2524http://hdl.handle.net/1969.1/ETD-TAMU-2524en_US
collection NDLTD
language en_US
format Others
sources NDLTD
topic Plutonium
wound
NaI(Tl)
HPGe
contamination
LANL

spellingShingle Plutonium
wound
NaI(Tl)
HPGe
contamination
LANL

Dimmerling, Paul James
Characterization of wound monitoring systems used to quantify and locate plutonium contamination
description When an accident involving the possibility of a plutonium contaminated wound occurs, the contamination is often quantified using sodium iodide (NaI(Tl)) and high purity germanium (HPGe) detection systems. The NaI(Tl) system is used to quantify the amount of contamination, while HPGe is used to gauge the depth of contamination in the wound. Assessment of plutonium contaminated wounds is difficult due to the lowenergy and yield of the uranium L-shell x rays used for the measurement, which can be effected by source distance, shape, and tissue attenuation. These effects on wound counting systems used at Los Alamos National Laboratory (LANL) were characterized experimentally using common source shapes (disk, point, and line) and acrylic plastic as a tissue substitute. Experiments were conducted to characterize detector responses as a function of tissue attenuation, source distance, and source depth in tissue. The computer code MCNP5 was used to model both systems for wound counting and better examine angular displacement of a line source in tissue. The NaI(Tl) detector response was characterized using absolute detector efficiency for all experimental measurements. Measurements showed that the NaI(Tl) system is significantly effected by the source to detector position and depth in tissue. Characterization of the HPGe detection system was done utilizing the peak-to-peak ratio from the two low-energy x rays. HPGe peak-to-peak ratios were not affected by source to detector distance, but showed an increased response to source depth in tissue. MCNP results suggested that small incident angles from the plane of the detector face can cause significant effects on the response of both detectors. In summary, the response of both systems showed dependence on source geometry and depth of contamination in tissue. Correction values and uncertainties were determined based on these dependencies.
author2 Braby, Leslie A.
author_facet Braby, Leslie A.
Dimmerling, Paul James
author Dimmerling, Paul James
author_sort Dimmerling, Paul James
title Characterization of wound monitoring systems used to quantify and locate plutonium contamination
title_short Characterization of wound monitoring systems used to quantify and locate plutonium contamination
title_full Characterization of wound monitoring systems used to quantify and locate plutonium contamination
title_fullStr Characterization of wound monitoring systems used to quantify and locate plutonium contamination
title_full_unstemmed Characterization of wound monitoring systems used to quantify and locate plutonium contamination
title_sort characterization of wound monitoring systems used to quantify and locate plutonium contamination
publishDate 2010
url http://hdl.handle.net/1969.1/ETD-TAMU-2524
http://hdl.handle.net/1969.1/ETD-TAMU-2524
work_keys_str_mv AT dimmerlingpauljames characterizationofwoundmonitoringsystemsusedtoquantifyandlocateplutoniumcontamination
_version_ 1716504036237115392