Quantifying the strain response in the rat tibia during simulated resistance training used as a disuse countermeasure

Disuse of weight bearing bones has been shown to cause bone loss. This poses a health concern for people exposed to microgravity, such as astronauts. Animal studies are used to study factors related to bone loss and countermeasures to prevent bone loss. This study used a hindlimb unloaded (HU) rat m...

Full description

Bibliographic Details
Main Author: Jeffery, Jay Melvin
Other Authors: Bloomfield, Susan A.
Format: Others
Language:en_US
Published: 2010
Subjects:
Rat
Online Access:http://hdl.handle.net/1969.1/ETD-TAMU-2087
http://hdl.handle.net/1969.1/ETD-TAMU-2087
id ndltd-tamu.edu-oai-repository.tamu.edu-1969.1-ETD-TAMU-2087
record_format oai_dc
spelling ndltd-tamu.edu-oai-repository.tamu.edu-1969.1-ETD-TAMU-20872013-01-08T10:39:26ZQuantifying the strain response in the rat tibia during simulated resistance training used as a disuse countermeasureJeffery, Jay MelvinStrainRatDisuseBoneTibiaMechanicsBiomechanicsExerciseMuscle stimualtionDisuse of weight bearing bones has been shown to cause bone loss. This poses a health concern for people exposed to microgravity, such as astronauts. Animal studies are used to study factors related to bone loss and countermeasures to prevent bone loss. This study used a hindlimb unloaded (HU) rat model to simulate microgravity and a muscle stimulation countermeasure to simulate resistive exercise. Uniaxial strain gages were implanted on the antero-medial aspect of the proximal tibia to measure the mechanical strain during a typical exercise session. In a separate but parallel study, the exercise was shown to be an effective countermeasure to disuse related bone loss. The current study sought to understand the loading of the bone during the exercise. To determine if the strain response changes during a protocol using this countermeasure, strains were measured on a group of weight bearing animals and a group that were hind limb unloaded and received the countermeasure for 21 days. Strain magnitudes and rates were considered and related to torques at the ankle joint. No significant differences in strain magnitudes were noted between the baseline control group and the hindlimb unloaded group that received the countermeasure. The two kinds of contractions used in an exercise session are isometric and eccentric. The isometric contractions are used to adjust the stimulation equipment for the eccentric contractions, which constitute the exercise. Peak strain levels during the isometric contractions ranged from 900 to 2200 microstrain while the eccentric were 38% lower and ranged from 600 to 1400. Eccentric strain rates were 62% lower than the isometric contractions strain rates. These results indicate that the strain environment during the isometric contractions may be causing more of the osteogenic response than the eccentric contractions, which have previously been thought to be the primary part of the countermeasure.Bloomfield, Susan A.Hogan, Harry A.2010-01-15T00:02:52Z2010-01-16T00:23:06Z2010-01-15T00:02:52Z2010-01-16T00:23:06Z2007-122009-05-15BookThesisElectronic Thesistextelectronicapplication/pdfborn digitalhttp://hdl.handle.net/1969.1/ETD-TAMU-2087http://hdl.handle.net/1969.1/ETD-TAMU-2087en_US
collection NDLTD
language en_US
format Others
sources NDLTD
topic Strain
Rat
Disuse
Bone
Tibia
Mechanics
Biomechanics
Exercise
Muscle stimualtion
spellingShingle Strain
Rat
Disuse
Bone
Tibia
Mechanics
Biomechanics
Exercise
Muscle stimualtion
Jeffery, Jay Melvin
Quantifying the strain response in the rat tibia during simulated resistance training used as a disuse countermeasure
description Disuse of weight bearing bones has been shown to cause bone loss. This poses a health concern for people exposed to microgravity, such as astronauts. Animal studies are used to study factors related to bone loss and countermeasures to prevent bone loss. This study used a hindlimb unloaded (HU) rat model to simulate microgravity and a muscle stimulation countermeasure to simulate resistive exercise. Uniaxial strain gages were implanted on the antero-medial aspect of the proximal tibia to measure the mechanical strain during a typical exercise session. In a separate but parallel study, the exercise was shown to be an effective countermeasure to disuse related bone loss. The current study sought to understand the loading of the bone during the exercise. To determine if the strain response changes during a protocol using this countermeasure, strains were measured on a group of weight bearing animals and a group that were hind limb unloaded and received the countermeasure for 21 days. Strain magnitudes and rates were considered and related to torques at the ankle joint. No significant differences in strain magnitudes were noted between the baseline control group and the hindlimb unloaded group that received the countermeasure. The two kinds of contractions used in an exercise session are isometric and eccentric. The isometric contractions are used to adjust the stimulation equipment for the eccentric contractions, which constitute the exercise. Peak strain levels during the isometric contractions ranged from 900 to 2200 microstrain while the eccentric were 38% lower and ranged from 600 to 1400. Eccentric strain rates were 62% lower than the isometric contractions strain rates. These results indicate that the strain environment during the isometric contractions may be causing more of the osteogenic response than the eccentric contractions, which have previously been thought to be the primary part of the countermeasure.
author2 Bloomfield, Susan A.
author_facet Bloomfield, Susan A.
Jeffery, Jay Melvin
author Jeffery, Jay Melvin
author_sort Jeffery, Jay Melvin
title Quantifying the strain response in the rat tibia during simulated resistance training used as a disuse countermeasure
title_short Quantifying the strain response in the rat tibia during simulated resistance training used as a disuse countermeasure
title_full Quantifying the strain response in the rat tibia during simulated resistance training used as a disuse countermeasure
title_fullStr Quantifying the strain response in the rat tibia during simulated resistance training used as a disuse countermeasure
title_full_unstemmed Quantifying the strain response in the rat tibia during simulated resistance training used as a disuse countermeasure
title_sort quantifying the strain response in the rat tibia during simulated resistance training used as a disuse countermeasure
publishDate 2010
url http://hdl.handle.net/1969.1/ETD-TAMU-2087
http://hdl.handle.net/1969.1/ETD-TAMU-2087
work_keys_str_mv AT jefferyjaymelvin quantifyingthestrainresponseintherattibiaduringsimulatedresistancetrainingusedasadisusecountermeasure
_version_ 1716503963590721536