Preliminary non-destructive assessment of moisture content, hydration and dielectric properties of Portland cement concrete

Moisture availability is a focal point in the structural development of young concrete. Under low humidity and hot weather conditions, concrete loses moisture rapidly as it hardens, and it is very difficult, if not impossible, to minimize this loss even though proper curing procedures are used. Earl...

Full description

Bibliographic Details
Main Author: Avelar Lezama, Ivan
Other Authors: Zollinger, Dan G.
Format: Others
Language:en_US
Published: Texas A&M University 2007
Subjects:
Online Access:http://hdl.handle.net/1969.1/4739
id ndltd-tamu.edu-oai-repository.tamu.edu-1969.1-4739
record_format oai_dc
spelling ndltd-tamu.edu-oai-repository.tamu.edu-1969.1-47392013-01-08T10:38:34ZPreliminary non-destructive assessment of moisture content, hydration and dielectric properties of Portland cement concreteAvelar Lezama, IvanDielectricMoistureMoisture availability is a focal point in the structural development of young concrete. Under low humidity and hot weather conditions, concrete loses moisture rapidly as it hardens, and it is very difficult, if not impossible, to minimize this loss even though proper curing procedures are used. Early losses in moisture content jumpstart premature surface self-dissecation, increase surface paste porosity, prevent concrete from achieving the mechanical properties for which it was originally designed, and facilitate the development of surface distresses such as spalling. Curing effectiveness and structural assessment of young concrete is generally done through conventional destructive or invasive testing. However, there is no fully established non-destructive testing protocol to assess moisture content and its effects on concrete properties quantitatively in an on-site, fast, and non-invasive way. The possibility and feasibility of establishing a testing protocol with such attributes is explored. Previous research on pavement bases has used dielectric measurements to relate moisture content to their structural performance. Due to the high dielectric value of water as compared to any other material used in construction, it is possible to relate high volumetric water content to high dielectric readings. In this study, compressive strength tests combined with dielectric and mass measurements are used to investigate how dielectric properties change with hydration. The results of this study suggest that it may be possible to approximate the volumetric moisture content in concrete by measuring the dielectric value of concrete as it hardens.Texas A&M UniversityZollinger, Dan G.2007-04-25T20:05:29Z2007-04-25T20:05:29Z2005-122007-04-25T20:05:29ZBookThesisElectronic Thesistext1651636 bytes2227200 byteselectronicapplication/pdfapplication/vnd.ms-excelborn digitalhttp://hdl.handle.net/1969.1/4739en_US
collection NDLTD
language en_US
format Others
sources NDLTD
topic Dielectric
Moisture
spellingShingle Dielectric
Moisture
Avelar Lezama, Ivan
Preliminary non-destructive assessment of moisture content, hydration and dielectric properties of Portland cement concrete
description Moisture availability is a focal point in the structural development of young concrete. Under low humidity and hot weather conditions, concrete loses moisture rapidly as it hardens, and it is very difficult, if not impossible, to minimize this loss even though proper curing procedures are used. Early losses in moisture content jumpstart premature surface self-dissecation, increase surface paste porosity, prevent concrete from achieving the mechanical properties for which it was originally designed, and facilitate the development of surface distresses such as spalling. Curing effectiveness and structural assessment of young concrete is generally done through conventional destructive or invasive testing. However, there is no fully established non-destructive testing protocol to assess moisture content and its effects on concrete properties quantitatively in an on-site, fast, and non-invasive way. The possibility and feasibility of establishing a testing protocol with such attributes is explored. Previous research on pavement bases has used dielectric measurements to relate moisture content to their structural performance. Due to the high dielectric value of water as compared to any other material used in construction, it is possible to relate high volumetric water content to high dielectric readings. In this study, compressive strength tests combined with dielectric and mass measurements are used to investigate how dielectric properties change with hydration. The results of this study suggest that it may be possible to approximate the volumetric moisture content in concrete by measuring the dielectric value of concrete as it hardens.
author2 Zollinger, Dan G.
author_facet Zollinger, Dan G.
Avelar Lezama, Ivan
author Avelar Lezama, Ivan
author_sort Avelar Lezama, Ivan
title Preliminary non-destructive assessment of moisture content, hydration and dielectric properties of Portland cement concrete
title_short Preliminary non-destructive assessment of moisture content, hydration and dielectric properties of Portland cement concrete
title_full Preliminary non-destructive assessment of moisture content, hydration and dielectric properties of Portland cement concrete
title_fullStr Preliminary non-destructive assessment of moisture content, hydration and dielectric properties of Portland cement concrete
title_full_unstemmed Preliminary non-destructive assessment of moisture content, hydration and dielectric properties of Portland cement concrete
title_sort preliminary non-destructive assessment of moisture content, hydration and dielectric properties of portland cement concrete
publisher Texas A&M University
publishDate 2007
url http://hdl.handle.net/1969.1/4739
work_keys_str_mv AT avelarlezamaivan preliminarynondestructiveassessmentofmoisturecontenthydrationanddielectricpropertiesofportlandcementconcrete
_version_ 1716503539100942336