Fiber Fabry-Perot interferometer (FFPI) sensor using vertical cavity surface emitting laser (VCSEL)

This research represents the first effort to apply vertical cavity surface emitting lasers (VCSELs) to the monitoring of interferometric fiber optic sensors. Modulation of the drive current causes thermal tuning of the laser light frequency. Reflection of this frequency-modulated light from a fiber...

Full description

Bibliographic Details
Main Author: Lee, Kyung-Woo
Other Authors: Taylor, Henry F.
Format: Others
Language:en_US
Published: Texas A&M University 2006
Subjects:
Online Access:http://hdl.handle.net/1969.1/4221
id ndltd-tamu.edu-oai-repository.tamu.edu-1969.1-4221
record_format oai_dc
spelling ndltd-tamu.edu-oai-repository.tamu.edu-1969.1-42212013-01-08T10:38:23ZFiber Fabry-Perot interferometer (FFPI) sensor using vertical cavity surface emitting laser (VCSEL)Lee, Kyung-Woofiberfabry-perotinterferometersensorffpivcselverticalcavitysurfaceemittinglaserThis research represents the first effort to apply vertical cavity surface emitting lasers (VCSELs) to the monitoring of interferometric fiber optic sensors. Modulation of the drive current causes thermal tuning of the laser light frequency. Reflection of this frequency-modulated light from a fiber Fabry-Perot interferometer (FFPI) sensor produces fringe patterns which can be used to measure the optical path difference of the sensor. Spectral characteristics were measured for 850nm VCSELs to determine the combination of dc bias current, modulation current amplitude and modulation frequency for which single mode VCSEL operation and regular fringe patterns are achieved. The response characteristics of FFPI sensors were determined experimentally for square, triangular, saw-tooth waveforms at frequencies from 10kHz to 100kHz. The dependence of VCSEL frequency on the dc bias current was determined from spectral measurements to be ~165GHz/mA. An independent measurement of this quantity based on counting fringes from the FFPI sensor as the laser modulated was in good agreement with this value. The effect of optical feedback into the laser was also studied. By observing the fringe shift as the FFPI sensor was heated, a fractional change in optical length with temperature of 6.95 X 10-6/°C was determined in good agreement with previous measurements on a 1300nm single mode fiber. The performance of 850nm VCSEL/FFPI systems was compared with their counterparts using 1300nm distributed feedback (DFB) lasers. The results of these experiments show that the 850nm VCSEL/FFPI combination gives regular fringe patterns at much lower bias current and modulating current amplitudes than their 1300nm DFB/FFPI counterparts.Texas A&M UniversityTaylor, Henry F.2006-10-30T23:25:36Z2006-10-30T23:25:36Z2005-082006-10-30T23:25:36ZBookThesisElectronic Dissertationtext1293696 byteselectronicapplication/pdfborn digitalhttp://hdl.handle.net/1969.1/4221en_US
collection NDLTD
language en_US
format Others
sources NDLTD
topic fiber
fabry-perot
interferometer
sensor
ffpi
vcsel
vertical
cavity
surface
emitting
laser
spellingShingle fiber
fabry-perot
interferometer
sensor
ffpi
vcsel
vertical
cavity
surface
emitting
laser
Lee, Kyung-Woo
Fiber Fabry-Perot interferometer (FFPI) sensor using vertical cavity surface emitting laser (VCSEL)
description This research represents the first effort to apply vertical cavity surface emitting lasers (VCSELs) to the monitoring of interferometric fiber optic sensors. Modulation of the drive current causes thermal tuning of the laser light frequency. Reflection of this frequency-modulated light from a fiber Fabry-Perot interferometer (FFPI) sensor produces fringe patterns which can be used to measure the optical path difference of the sensor. Spectral characteristics were measured for 850nm VCSELs to determine the combination of dc bias current, modulation current amplitude and modulation frequency for which single mode VCSEL operation and regular fringe patterns are achieved. The response characteristics of FFPI sensors were determined experimentally for square, triangular, saw-tooth waveforms at frequencies from 10kHz to 100kHz. The dependence of VCSEL frequency on the dc bias current was determined from spectral measurements to be ~165GHz/mA. An independent measurement of this quantity based on counting fringes from the FFPI sensor as the laser modulated was in good agreement with this value. The effect of optical feedback into the laser was also studied. By observing the fringe shift as the FFPI sensor was heated, a fractional change in optical length with temperature of 6.95 X 10-6/°C was determined in good agreement with previous measurements on a 1300nm single mode fiber. The performance of 850nm VCSEL/FFPI systems was compared with their counterparts using 1300nm distributed feedback (DFB) lasers. The results of these experiments show that the 850nm VCSEL/FFPI combination gives regular fringe patterns at much lower bias current and modulating current amplitudes than their 1300nm DFB/FFPI counterparts.
author2 Taylor, Henry F.
author_facet Taylor, Henry F.
Lee, Kyung-Woo
author Lee, Kyung-Woo
author_sort Lee, Kyung-Woo
title Fiber Fabry-Perot interferometer (FFPI) sensor using vertical cavity surface emitting laser (VCSEL)
title_short Fiber Fabry-Perot interferometer (FFPI) sensor using vertical cavity surface emitting laser (VCSEL)
title_full Fiber Fabry-Perot interferometer (FFPI) sensor using vertical cavity surface emitting laser (VCSEL)
title_fullStr Fiber Fabry-Perot interferometer (FFPI) sensor using vertical cavity surface emitting laser (VCSEL)
title_full_unstemmed Fiber Fabry-Perot interferometer (FFPI) sensor using vertical cavity surface emitting laser (VCSEL)
title_sort fiber fabry-perot interferometer (ffpi) sensor using vertical cavity surface emitting laser (vcsel)
publisher Texas A&M University
publishDate 2006
url http://hdl.handle.net/1969.1/4221
work_keys_str_mv AT leekyungwoo fiberfabryperotinterferometerffpisensorusingverticalcavitysurfaceemittinglaservcsel
_version_ 1716503441626365952