The effects between two slotted plate flow meter under single, two, three components flow condition

In previous work on the slotted flow meter, repeatibility and reproducibility were studied under different flow conditions and different configurations. In accordance with previous work, the effects of the distance between the slotted plate were identified as an area requring further investigation....

Full description

Bibliographic Details
Main Author: Park, Sang Hyan
Other Authors: Morrison, Gerald L.
Format: Others
Language:en_US
Published: Texas A&M University 2005
Subjects:
Online Access:http://hdl.handle.net/1969.1/1522
id ndltd-tamu.edu-oai-repository.tamu.edu-1969.1-1522
record_format oai_dc
spelling ndltd-tamu.edu-oai-repository.tamu.edu-1969.1-15222013-01-08T10:37:39ZThe effects between two slotted plate flow meter under single, two, three components flow conditionPark, Sang HyanMultiphseFlow MeterPetroluem EngineeringIn previous work on the slotted flow meter, repeatibility and reproducibility were studied under different flow conditions and different configurations. In accordance with previous work, the effects of the distance between the slotted plate were identified as an area requring further investigation. The preset 5D distance is expanded to the 10D distance. The flow coefficient KY, the pressure drop, and the uncertainty analysis is conducted. There were definite deference in the results between the 5D distance and the 10D distance in many aspects. As a base line, the flow coefficient KY showed 0.8% ~ 2% difference between the 5D and the 10D distance case. Depending upon the upstream flow conditions, the reproducibility of the slotted flow meter was affected. The pressure drop increased as the upstream Reynolds number increased. The result from the analysis of the water cut meter showed that there are definite relationships between the parameteres of the water cut meter and the parameters of the flow.Texas A&M UniversityMorrison, Gerald L.2005-02-17T21:04:06Z2005-02-17T21:04:06Z2004-122005-02-17T21:04:06ZBookThesisElectronic Thesistext2881653 byteselectronicapplication/pdfborn digitalhttp://hdl.handle.net/1969.1/1522en_US
collection NDLTD
language en_US
format Others
sources NDLTD
topic Multiphse
Flow Meter
Petroluem Engineering
spellingShingle Multiphse
Flow Meter
Petroluem Engineering
Park, Sang Hyan
The effects between two slotted plate flow meter under single, two, three components flow condition
description In previous work on the slotted flow meter, repeatibility and reproducibility were studied under different flow conditions and different configurations. In accordance with previous work, the effects of the distance between the slotted plate were identified as an area requring further investigation. The preset 5D distance is expanded to the 10D distance. The flow coefficient KY, the pressure drop, and the uncertainty analysis is conducted. There were definite deference in the results between the 5D distance and the 10D distance in many aspects. As a base line, the flow coefficient KY showed 0.8% ~ 2% difference between the 5D and the 10D distance case. Depending upon the upstream flow conditions, the reproducibility of the slotted flow meter was affected. The pressure drop increased as the upstream Reynolds number increased. The result from the analysis of the water cut meter showed that there are definite relationships between the parameteres of the water cut meter and the parameters of the flow.
author2 Morrison, Gerald L.
author_facet Morrison, Gerald L.
Park, Sang Hyan
author Park, Sang Hyan
author_sort Park, Sang Hyan
title The effects between two slotted plate flow meter under single, two, three components flow condition
title_short The effects between two slotted plate flow meter under single, two, three components flow condition
title_full The effects between two slotted plate flow meter under single, two, three components flow condition
title_fullStr The effects between two slotted plate flow meter under single, two, three components flow condition
title_full_unstemmed The effects between two slotted plate flow meter under single, two, three components flow condition
title_sort effects between two slotted plate flow meter under single, two, three components flow condition
publisher Texas A&M University
publishDate 2005
url http://hdl.handle.net/1969.1/1522
work_keys_str_mv AT parksanghyan theeffectsbetweentwoslottedplateflowmeterundersingletwothreecomponentsflowcondition
AT parksanghyan effectsbetweentwoslottedplateflowmeterundersingletwothreecomponentsflowcondition
_version_ 1716502825056337920