[en] METROLOGICAL RELIABILITY OF THE ANTIDOPING LABORATORY OF THE BRAZILIAN JOCKEY CLUB. STUDY CASE: VALIDATION OF ANALYTICAL METHOD FOR DETERMINATION OF CAFFEINE IN URINE OF RACE HORSES
[pt] A presente pesquisa de mestrado relaciona-se ao desenvolvimento e à validação de um método analítico para detecção de substâncias proibidas em matrizes biológicas de cavalos de corrida e seu impacto na confiabilidade metrológica de serviços laboratoriais voltados à atividade turfística visa...
Main Author: | |
---|---|
Other Authors: | |
Language: | pt |
Published: |
MAXWELL
2004
|
Subjects: | |
Online Access: | https://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=5563@1 https://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=5563@2 http://doi.org/10.17771/PUCRio.acad.5563 |
id |
ndltd-puc-rio.br-oai-MAXWELL.puc-rio.br-5563 |
---|---|
record_format |
oai_dc |
collection |
NDLTD |
language |
pt |
sources |
NDLTD |
topic |
[pt] CONFIABILIDADE METROLOGICA [en] RELIABLE MEASUREMENT PRACTICES [pt] VALIDACAO DE METODOS ANALITICOS [en] VALIDATION OF ANALYTICAL METHODS [pt] METROLOGIA QUIMICA [en] CHEMICAL METROLOGY [pt] CAFEINA [en] CAFFEINE [pt] DOPAGEM [en] DOPING |
spellingShingle |
[pt] CONFIABILIDADE METROLOGICA [en] RELIABLE MEASUREMENT PRACTICES [pt] VALIDACAO DE METODOS ANALITICOS [en] VALIDATION OF ANALYTICAL METHODS [pt] METROLOGIA QUIMICA [en] CHEMICAL METROLOGY [pt] CAFEINA [en] CAFFEINE [pt] DOPAGEM [en] DOPING INDIA MARIA HILUF DE LIMA [en] METROLOGICAL RELIABILITY OF THE ANTIDOPING LABORATORY OF THE BRAZILIAN JOCKEY CLUB. STUDY CASE: VALIDATION OF ANALYTICAL METHOD FOR DETERMINATION OF CAFFEINE IN URINE OF RACE HORSES |
description |
[pt] A presente pesquisa de mestrado relaciona-se ao
desenvolvimento e à
validação de um método analítico para detecção de
substâncias proibidas em
matrizes biológicas de cavalos de corrida e seu impacto na
confiabilidade
metrológica de serviços laboratoriais voltados à atividade
turfística visando (i) a
especificação de desempenho de um laboratório antidoping
capacitado para
identificar a presença de substâncias proibidas acordadas
pela indústria de
carreiras de cavalo; (ii) a adequação às condições
brasileiras dos métodos
analíticos aplicáveis à determinação antidoping em matrizes
biológicas de
animais em competição e (iii) a definição de um padrão de
excelência
harmonizado aos critérios da International Federation of
Horseracing Authorities
entendidos como instrumentos para a conquista do
credenciamento do
laboratório antidoping e subseqüente participação em
acordos internacionais de
reconhecimento mútuo. Para fundamentar o desenvolvimento da
pesquisa, o
trabalho considerou como estudo de caso o Laboratório
Antidoping do Jockey
Club Brasileiro (LAD/JCB).
Original no seu escopo, o trabalho contribui para ampliar a
abrangência da
atividade de acreditação laboratorial no Brasil tendo em
vista tratar-se de uma
nova categoria de laboratório de ensaio ainda não existente
na matriz
laboratorial credenciada cuja confiabilidade laboratorial
foi desenvolvida à luz
dos critérios da norma internacional ISO/IEC 17025.
No contexto do desenvolvimento são ainda discutidos
aspectos relevantes
relacionados ao sistema da gestão laboratorial; expressão
das incertezas de
medição associadas à determinação antidoping em consonância
a práticas e
procedimentos internacionalmente consensados; capacitação
de pessoal técnico
especializado; rastreabilidade ao Sistema Internacional de
Unidades (SI) e
validação e adequação de metodologias analíticas utilizadas
em laboratórios
antidoping.
Atenção particular é direcionada ao Methode Alcalins Sur C-
18,
desenvolvido pelo Laboratoire LAB-Contrôle antidopage da
França, aplicável a
determinação da presença de substâncias dopantes em
matrizes biológicas (urina) de cavalos de corrida,
utilizado como método fonte para o
desenvolvimento de um método alternativo adequado às
condições laboratoriais
do Laboratório Antidoping do Jockey Club Brasileiro e
moldado à detecção de
substâncias dopantes mais freqüentes na atividade
turfística brasileira.
Tendo a cafeína sido estatisticamente identificada a
substância mais
presente nas análises realizadas pelo Laboratório
Antidoping do Jockey Club
Brasileiro ao longo de seus sete anos de atuação, o Methode
Alcalins Sur C-18
foi adequado e validado para sua determinação analítica. À
pesquisa
desenvolvida atribuem-se, também, créditos pela introdução
de um novo atributo
na validação qualitativa da metodologia, denominado valor-
limite de
determinação, subsidiando a determinação de uma faixa de
concentração, para
que resultados incorretos (falso-positivos e falso-
negativos) não constem de
laudos emitidos.
Adicionalmente à adequação e validação do método analítico
desenvolvido, a pesquisa de mestrado contribuiu não apenas
para atribuir
visibilidade a uma nova categoria de laboratórios, mas,
principalmente, para
preparar o Laboratório Antidoping do Jockey Club Brasileiro
para demonstrar sua
competência técnica como estratégia de conquista de um
credenciamento
internacionalmente reconhecido.
A presente pesquisa de mestrado voltada ao equacionamento
de um
problema inédito no Brasil de interesse da indústria
relacionada à atividade
turfística desenvolveu-se no contexto do Convênio FINEP/MCT
no.
22.01.0692.00, Referência 1974/01, que aportou recursos do
Fundo Setorial
Verde Amarelo para direcionar o esforço de pesquisa em
metrologia para a
solução de dez projetos-piloto de interesse da indústria.
No c === [en] This Master s Degree dissertation addresses the development
in
adjustment and validation and the metrological reliability
of laboratory services
covering horseracing activities. The work includes (i) the
specification of the
performance of an antidoping laboratory capable of
identifying the presence of
forbidden substances, as defined by the horse-racing
industry; (ii) the validation
of analytical methods applicable in doping tests of
biological matrices of
competing animals to Brazilian laboratories conditions, and
(iii) the definition of a
standard of excellence in harmony with the criteria of the
International Federation
of Horseracing Authorities as the tools utilized for the
accreditation of the
antidoping laboratory and the subsequent participation in
international
agreements of mutual recognition. In order to validate the
methodology, the
Brazilian Jockey Club Antidoping Laboratory (LAD/JCB) was
used as a studycase.
Original in its scope, this work contributes towards the
widening of the
accreditation of laboratories in Brazil, considering the
fact this new category of
testing laboratories is still nonexistent within the
Brazilian network of accredited
testing laboratories which considers the international
standard ISO/IEC 17025 as
the basic criteria.
With regard to development, some relevant aspects are still
being
discussed in relation to the laboratory management system:
the unreliability of
the measurements for the determination of doping, in view
of internationally
accepted practices and procedures; qualification of
specialized technical
personnel; traceability of SI (the International Unit
System) and the validation and
adjustment of analytical methodologies utilized in
antidoping laboratories.
Special attention is dedicated to Methode Alcalins Sur C-
18, developed by
Laboratoire LAB-Contrôle Antidopage in France, applicable
to the determination
of the presence of doping substances in the biological
matrix (urine) of racehorses, used as method source for the
development of an alternative method
adjusted to the Antidoping Laboratory of the Brazilian
Jockey Club conditions and
molded to detection of the more frequents doping substances
in the brazilian
horserancing activities.
Having the caffeine been the doping substance statistically
identified as the
most frequent in the tests carried out by the Brazilian
Jockey Club Antidoping
Laboratory, along its seven years of services, the Methode
Alcalins Sur C-18
was adapted and validated for its analytical
determinations. The applied research
carried out was also credited with the introduction of a
new attribute to the
methodology qualitative validation, designated as limit-
value for determination,
which provides key-information for the determination of a
concentration band, in
order that incorrect results (false-positive and false-
negative) do not appear in
the laboratory reports usually issued.
Besides the adaptation and validation of the analytical
method thus
developed, this Master s Degree dissertation contributes
not only towards greater
visibility of a new category of laboratories, but mainly to
the preparation of the
Brazilian Jockey Club Antidoping Laboratory to demonstrate
its technical capacity
as a policy and strategy for becoming in the near future an
internationally
recognized accredited laboratory.
The present M.Sc. Dissertation addresses the metrological
reliability of
antidoping laboratories, a pioneering issue in Brazil,
aiming at the solution of a
problem related to the horse-racing industry. It was
developed under the financial
support of the FINEP/MCT Agreement no. 22.01.0692.00,
Reference 1974/01
(Green-Yellow governmental Sectoral Fund) which droved
research cooperative
efforts in metrology to the solution of ten pilot-projects.
In this case specifically,
cooperated to the development of the M.Sc. research
entitled Metrological
reliability of the Antidoping Laboratory of the Brazilian
Jockey Club |
author2 |
MAURICIO NOGUEIRA FROTA |
author_facet |
MAURICIO NOGUEIRA FROTA INDIA MARIA HILUF DE LIMA |
author |
INDIA MARIA HILUF DE LIMA |
author_sort |
INDIA MARIA HILUF DE LIMA |
title |
[en] METROLOGICAL RELIABILITY OF THE ANTIDOPING LABORATORY OF THE BRAZILIAN JOCKEY CLUB. STUDY CASE: VALIDATION OF ANALYTICAL METHOD FOR DETERMINATION OF CAFFEINE IN URINE OF RACE HORSES |
title_short |
[en] METROLOGICAL RELIABILITY OF THE ANTIDOPING LABORATORY OF THE BRAZILIAN JOCKEY CLUB. STUDY CASE: VALIDATION OF ANALYTICAL METHOD FOR DETERMINATION OF CAFFEINE IN URINE OF RACE HORSES |
title_full |
[en] METROLOGICAL RELIABILITY OF THE ANTIDOPING LABORATORY OF THE BRAZILIAN JOCKEY CLUB. STUDY CASE: VALIDATION OF ANALYTICAL METHOD FOR DETERMINATION OF CAFFEINE IN URINE OF RACE HORSES |
title_fullStr |
[en] METROLOGICAL RELIABILITY OF THE ANTIDOPING LABORATORY OF THE BRAZILIAN JOCKEY CLUB. STUDY CASE: VALIDATION OF ANALYTICAL METHOD FOR DETERMINATION OF CAFFEINE IN URINE OF RACE HORSES |
title_full_unstemmed |
[en] METROLOGICAL RELIABILITY OF THE ANTIDOPING LABORATORY OF THE BRAZILIAN JOCKEY CLUB. STUDY CASE: VALIDATION OF ANALYTICAL METHOD FOR DETERMINATION OF CAFFEINE IN URINE OF RACE HORSES |
title_sort |
[en] metrological reliability of the antidoping laboratory of the brazilian jockey club. study case: validation of analytical method for determination of caffeine in urine of race horses |
publisher |
MAXWELL |
publishDate |
2004 |
url |
https://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=5563@1 https://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=5563@2 http://doi.org/10.17771/PUCRio.acad.5563 |
work_keys_str_mv |
AT indiamariahilufdelima enmetrologicalreliabilityoftheantidopinglaboratoryofthebrazilianjockeyclubstudycasevalidationofanalyticalmethodfordeterminationofcaffeineinurineofracehorses AT indiamariahilufdelima ptconfiabilidademetrologicadolaboratorioantidopingdojockeyclubbrasileiroestudodecasovalidacaodemetodoanaliticoparadeterminacaodecafeinaemurinadecavalosdecorrida |
_version_ |
1718712704159449088 |
spelling |
ndltd-puc-rio.br-oai-MAXWELL.puc-rio.br-55632018-07-17T04:11:22Z[en] METROLOGICAL RELIABILITY OF THE ANTIDOPING LABORATORY OF THE BRAZILIAN JOCKEY CLUB. STUDY CASE: VALIDATION OF ANALYTICAL METHOD FOR DETERMINATION OF CAFFEINE IN URINE OF RACE HORSES[pt] CONFIABILIDADE METROLÓGICA DO LABORATÓRIO ANTIDOPING DO JOCKEY CLUB BRASILEIRO. ESTUDO DE CASO: VALIDAÇÃO DE MÉTODO ANALÍTICO PARA DETERMINAÇÃO DE CAFEÍNA EM URINA DE CAVALOS DE CORRIDAINDIA MARIA HILUF DE LIMA[pt] CONFIABILIDADE METROLOGICA[en] RELIABLE MEASUREMENT PRACTICES[pt] VALIDACAO DE METODOS ANALITICOS[en] VALIDATION OF ANALYTICAL METHODS[pt] METROLOGIA QUIMICA[en] CHEMICAL METROLOGY[pt] CAFEINA[en] CAFFEINE[pt] DOPAGEM[en] DOPING[pt] A presente pesquisa de mestrado relaciona-se ao desenvolvimento e à validação de um método analítico para detecção de substâncias proibidas em matrizes biológicas de cavalos de corrida e seu impacto na confiabilidade metrológica de serviços laboratoriais voltados à atividade turfística visando (i) a especificação de desempenho de um laboratório antidoping capacitado para identificar a presença de substâncias proibidas acordadas pela indústria de carreiras de cavalo; (ii) a adequação às condições brasileiras dos métodos analíticos aplicáveis à determinação antidoping em matrizes biológicas de animais em competição e (iii) a definição de um padrão de excelência harmonizado aos critérios da International Federation of Horseracing Authorities entendidos como instrumentos para a conquista do credenciamento do laboratório antidoping e subseqüente participação em acordos internacionais de reconhecimento mútuo. Para fundamentar o desenvolvimento da pesquisa, o trabalho considerou como estudo de caso o Laboratório Antidoping do Jockey Club Brasileiro (LAD/JCB). Original no seu escopo, o trabalho contribui para ampliar a abrangência da atividade de acreditação laboratorial no Brasil tendo em vista tratar-se de uma nova categoria de laboratório de ensaio ainda não existente na matriz laboratorial credenciada cuja confiabilidade laboratorial foi desenvolvida à luz dos critérios da norma internacional ISO/IEC 17025. No contexto do desenvolvimento são ainda discutidos aspectos relevantes relacionados ao sistema da gestão laboratorial; expressão das incertezas de medição associadas à determinação antidoping em consonância a práticas e procedimentos internacionalmente consensados; capacitação de pessoal técnico especializado; rastreabilidade ao Sistema Internacional de Unidades (SI) e validação e adequação de metodologias analíticas utilizadas em laboratórios antidoping. Atenção particular é direcionada ao Methode Alcalins Sur C- 18, desenvolvido pelo Laboratoire LAB-Contrôle antidopage da França, aplicável a determinação da presença de substâncias dopantes em matrizes biológicas (urina) de cavalos de corrida, utilizado como método fonte para o desenvolvimento de um método alternativo adequado às condições laboratoriais do Laboratório Antidoping do Jockey Club Brasileiro e moldado à detecção de substâncias dopantes mais freqüentes na atividade turfística brasileira. Tendo a cafeína sido estatisticamente identificada a substância mais presente nas análises realizadas pelo Laboratório Antidoping do Jockey Club Brasileiro ao longo de seus sete anos de atuação, o Methode Alcalins Sur C-18 foi adequado e validado para sua determinação analítica. À pesquisa desenvolvida atribuem-se, também, créditos pela introdução de um novo atributo na validação qualitativa da metodologia, denominado valor- limite de determinação, subsidiando a determinação de uma faixa de concentração, para que resultados incorretos (falso-positivos e falso- negativos) não constem de laudos emitidos. Adicionalmente à adequação e validação do método analítico desenvolvido, a pesquisa de mestrado contribuiu não apenas para atribuir visibilidade a uma nova categoria de laboratórios, mas, principalmente, para preparar o Laboratório Antidoping do Jockey Club Brasileiro para demonstrar sua competência técnica como estratégia de conquista de um credenciamento internacionalmente reconhecido. A presente pesquisa de mestrado voltada ao equacionamento de um problema inédito no Brasil de interesse da indústria relacionada à atividade turfística desenvolveu-se no contexto do Convênio FINEP/MCT no. 22.01.0692.00, Referência 1974/01, que aportou recursos do Fundo Setorial Verde Amarelo para direcionar o esforço de pesquisa em metrologia para a solução de dez projetos-piloto de interesse da indústria. No c[en] This Master s Degree dissertation addresses the development in adjustment and validation and the metrological reliability of laboratory services covering horseracing activities. The work includes (i) the specification of the performance of an antidoping laboratory capable of identifying the presence of forbidden substances, as defined by the horse-racing industry; (ii) the validation of analytical methods applicable in doping tests of biological matrices of competing animals to Brazilian laboratories conditions, and (iii) the definition of a standard of excellence in harmony with the criteria of the International Federation of Horseracing Authorities as the tools utilized for the accreditation of the antidoping laboratory and the subsequent participation in international agreements of mutual recognition. In order to validate the methodology, the Brazilian Jockey Club Antidoping Laboratory (LAD/JCB) was used as a studycase. Original in its scope, this work contributes towards the widening of the accreditation of laboratories in Brazil, considering the fact this new category of testing laboratories is still nonexistent within the Brazilian network of accredited testing laboratories which considers the international standard ISO/IEC 17025 as the basic criteria. With regard to development, some relevant aspects are still being discussed in relation to the laboratory management system: the unreliability of the measurements for the determination of doping, in view of internationally accepted practices and procedures; qualification of specialized technical personnel; traceability of SI (the International Unit System) and the validation and adjustment of analytical methodologies utilized in antidoping laboratories. Special attention is dedicated to Methode Alcalins Sur C- 18, developed by Laboratoire LAB-Contrôle Antidopage in France, applicable to the determination of the presence of doping substances in the biological matrix (urine) of racehorses, used as method source for the development of an alternative method adjusted to the Antidoping Laboratory of the Brazilian Jockey Club conditions and molded to detection of the more frequents doping substances in the brazilian horserancing activities. Having the caffeine been the doping substance statistically identified as the most frequent in the tests carried out by the Brazilian Jockey Club Antidoping Laboratory, along its seven years of services, the Methode Alcalins Sur C-18 was adapted and validated for its analytical determinations. The applied research carried out was also credited with the introduction of a new attribute to the methodology qualitative validation, designated as limit- value for determination, which provides key-information for the determination of a concentration band, in order that incorrect results (false-positive and false- negative) do not appear in the laboratory reports usually issued. Besides the adaptation and validation of the analytical method thus developed, this Master s Degree dissertation contributes not only towards greater visibility of a new category of laboratories, but mainly to the preparation of the Brazilian Jockey Club Antidoping Laboratory to demonstrate its technical capacity as a policy and strategy for becoming in the near future an internationally recognized accredited laboratory. The present M.Sc. Dissertation addresses the metrological reliability of antidoping laboratories, a pioneering issue in Brazil, aiming at the solution of a problem related to the horse-racing industry. It was developed under the financial support of the FINEP/MCT Agreement no. 22.01.0692.00, Reference 1974/01 (Green-Yellow governmental Sectoral Fund) which droved research cooperative efforts in metrology to the solution of ten pilot-projects. In this case specifically, cooperated to the development of the M.Sc. research entitled Metrological reliability of the Antidoping Laboratory of the Brazilian Jockey ClubMAXWELLMAURICIO NOGUEIRA FROTA2004-10-08TEXTOhttps://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=5563@1https://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=5563@2http://doi.org/10.17771/PUCRio.acad.5563pt |