[en] LLUMINANCE MEASUREMENT BY MOBILE DEVICES: A COMPARATIVE ANALYSIS OF DIFFERENT PLATFORMS AND APPLICATIONS

[pt] A iluminância do ambiente apresenta impacto fisiológico, emocional e de produtividade, em função das atividades que os indivíduos estejam desempenhando. Normas técnicas internacionais, que são adotadas no Brasil pela ABNT, apresentam requisitos necessários para os níveis de iluminância existent...

Full description

Bibliographic Details
Main Author: VIVIANE GODINHO VAZ
Other Authors: ELISABETH COSTA MONTEIRO
Language:pt
Published: MAXWELL 2019
Subjects:
Online Access:http://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=36378@1
http://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=36378@2
http://doi.org/10.17771/PUCRio.acad.36378
id ndltd-puc-rio.br-oai-MAXWELL.puc-rio.br-36378
record_format oai_dc
collection NDLTD
language pt
sources NDLTD
topic [pt] METROLOGIA
[en] METROLOGY
[pt] CONFIABILIDADE METROLOGICA
[en] RELIABLE MEASUREMENT PRACTICES
[pt] MEDICAO DE ILUMINANCIA
[en] ILLUMINATION MEDICATION
[pt] LUXIMETRO
[en] LUXIMETER
[pt] APLICATIVOS PARA SMARTPHONE E TABLET
[en] SMARTPHONE AND TABLET APPS
spellingShingle [pt] METROLOGIA
[en] METROLOGY
[pt] CONFIABILIDADE METROLOGICA
[en] RELIABLE MEASUREMENT PRACTICES
[pt] MEDICAO DE ILUMINANCIA
[en] ILLUMINATION MEDICATION
[pt] LUXIMETRO
[en] LUXIMETER
[pt] APLICATIVOS PARA SMARTPHONE E TABLET
[en] SMARTPHONE AND TABLET APPS
VIVIANE GODINHO VAZ
[en] LLUMINANCE MEASUREMENT BY MOBILE DEVICES: A COMPARATIVE ANALYSIS OF DIFFERENT PLATFORMS AND APPLICATIONS
description [pt] A iluminância do ambiente apresenta impacto fisiológico, emocional e de produtividade, em função das atividades que os indivíduos estejam desempenhando. Normas técnicas internacionais, que são adotadas no Brasil pela ABNT, apresentam requisitos necessários para os níveis de iluminância existentes em ambientes indoor de forma a garantir segurança, conforto e eficiência em tarefas visuais durante todo um período de trabalho. Instrumentos de medição, como luxímetros, em geral, não são utilizados no quotidiano. No entanto, a possibilidade de que os sensores já existentes em dispositivos móveis possam realizar essas medições de iluminância tornará viável sua aplicação no quotidiano do usuário, permitindo avaliar a adequação dessa grandeza durante suas atividades diárias. Resultados preliminares disponíveis na literatura, comparando o desempenho de dispositivos móveis associados a diferentes aplicativos comparados aos resultados de medição fornecidos por um luxímetro, apontam para a inadequação da resposta dos dispositivos móveis. Por outro lado, há possibilidade de que o uso de uma cúpula difusora acoplada ao dispositivo móvel possa impactar em seu desempenho de forma a viabilizar a aplicação na medição de iluminância. Assim, neste trabalho são realizados estudos para análise da confiabilidade dos resultados de medição da iluminância obtidos pelos sensores já existentes em smartphones e tablets, utilizando ou não uma cúpula difusora. As medições foram feitas utilizando um luxímetro digital, e um conjunto de dispositivos de telefonia móvel ou tablet associados a diferentes aplicativos, com e sem cúpula difusora anexada. Dois arranjos experimentais foram desenvolvidos: um para medições utilizando uma lâmpada LED, e outra montagem utilizando uma lâmpada de xenônio. Com a análise comparativa evidenciou-se o impacto da utilização da cúpula difusora, a qual possibilitou que algumas das combinações dispositivo/aplicativo alcançassem desempenho adequado para sua aplicação na avaliação quotidiana de iluminância. === [en] The illuminance of the environment has a physiological, emotional and productivity impact, depending on the activities that individuals are performing. International technical standards, such as ISO 8995-1: 2002 (CIE S 008 / E: 2001), also adopted in Brazil by ABNT, present requirements for the levels of illuminance existing in indoor environments in order to guarantee safety, comfort and efficiency in visual tasks throughout a work period. Measuring instruments such as luxmeters, are not used in everyday life. However, the possibility that the existing sensors in mobile devices can perform these measurements of illuminance will make its application viable in the daily life of the user, allowing to evaluate the adequacy of this greatness during his daily activities. Preliminary results available in the literature, comparing the performance of mobile devices associated with different applications in relation to the measurement results provided by a luxmeter, point to the inadequacy of the response of the mobile devices. On the other hand, it is possible that the use of a diffuser dome coupled to the mobile device may impact its performance to enable the application in the illuminance measurement. Thus, in this work are carried out studies to analyze the reliability of the illuminance values obtained by sensors already existing in smartphones and tablets, using or not a dome diffuser. The measurements were made using as reference, a digital luxmeter, and a set of mobile or tablet devices associated with different applications, in situations with and without diffuser dome attached. Two experimental arrangements were developed: one for measurements using a LED lamp, and another assembly using a xenon lamp. With the comparative analysis, the impact of the use of the diffusion dome was evidenced. The attachment of the dome enabled some of the device/application combinations to achieve adequate performance for application in the daily assessment of illuminance.
author2 ELISABETH COSTA MONTEIRO
author_facet ELISABETH COSTA MONTEIRO
VIVIANE GODINHO VAZ
author VIVIANE GODINHO VAZ
author_sort VIVIANE GODINHO VAZ
title [en] LLUMINANCE MEASUREMENT BY MOBILE DEVICES: A COMPARATIVE ANALYSIS OF DIFFERENT PLATFORMS AND APPLICATIONS
title_short [en] LLUMINANCE MEASUREMENT BY MOBILE DEVICES: A COMPARATIVE ANALYSIS OF DIFFERENT PLATFORMS AND APPLICATIONS
title_full [en] LLUMINANCE MEASUREMENT BY MOBILE DEVICES: A COMPARATIVE ANALYSIS OF DIFFERENT PLATFORMS AND APPLICATIONS
title_fullStr [en] LLUMINANCE MEASUREMENT BY MOBILE DEVICES: A COMPARATIVE ANALYSIS OF DIFFERENT PLATFORMS AND APPLICATIONS
title_full_unstemmed [en] LLUMINANCE MEASUREMENT BY MOBILE DEVICES: A COMPARATIVE ANALYSIS OF DIFFERENT PLATFORMS AND APPLICATIONS
title_sort [en] lluminance measurement by mobile devices: a comparative analysis of different platforms and applications
publisher MAXWELL
publishDate 2019
url http://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=36378@1
http://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=36378@2
http://doi.org/10.17771/PUCRio.acad.36378
work_keys_str_mv AT vivianegodinhovaz enlluminancemeasurementbymobiledevicesacomparativeanalysisofdifferentplatformsandapplications
AT vivianegodinhovaz ptmedicaodeiluminanciapordispositivosmoveisumaanalisecomparativadediferentesplataformaseaplicativos
_version_ 1718969786981941248
spelling ndltd-puc-rio.br-oai-MAXWELL.puc-rio.br-363782019-02-01T04:17:22Z[en] LLUMINANCE MEASUREMENT BY MOBILE DEVICES: A COMPARATIVE ANALYSIS OF DIFFERENT PLATFORMS AND APPLICATIONS[pt] MEDIÇÃO DE ILUMINÂNCIA POR DISPOSITIVOS MÓVEIS: UMA ANÁLISE COMPARATIVA DE DIFERENTES PLATAFORMAS E APLICATIVOSVIVIANE GODINHO VAZ[pt] METROLOGIA[en] METROLOGY[pt] CONFIABILIDADE METROLOGICA[en] RELIABLE MEASUREMENT PRACTICES[pt] MEDICAO DE ILUMINANCIA[en] ILLUMINATION MEDICATION[pt] LUXIMETRO[en] LUXIMETER[pt] APLICATIVOS PARA SMARTPHONE E TABLET[en] SMARTPHONE AND TABLET APPS[pt] A iluminância do ambiente apresenta impacto fisiológico, emocional e de produtividade, em função das atividades que os indivíduos estejam desempenhando. Normas técnicas internacionais, que são adotadas no Brasil pela ABNT, apresentam requisitos necessários para os níveis de iluminância existentes em ambientes indoor de forma a garantir segurança, conforto e eficiência em tarefas visuais durante todo um período de trabalho. Instrumentos de medição, como luxímetros, em geral, não são utilizados no quotidiano. No entanto, a possibilidade de que os sensores já existentes em dispositivos móveis possam realizar essas medições de iluminância tornará viável sua aplicação no quotidiano do usuário, permitindo avaliar a adequação dessa grandeza durante suas atividades diárias. Resultados preliminares disponíveis na literatura, comparando o desempenho de dispositivos móveis associados a diferentes aplicativos comparados aos resultados de medição fornecidos por um luxímetro, apontam para a inadequação da resposta dos dispositivos móveis. Por outro lado, há possibilidade de que o uso de uma cúpula difusora acoplada ao dispositivo móvel possa impactar em seu desempenho de forma a viabilizar a aplicação na medição de iluminância. Assim, neste trabalho são realizados estudos para análise da confiabilidade dos resultados de medição da iluminância obtidos pelos sensores já existentes em smartphones e tablets, utilizando ou não uma cúpula difusora. As medições foram feitas utilizando um luxímetro digital, e um conjunto de dispositivos de telefonia móvel ou tablet associados a diferentes aplicativos, com e sem cúpula difusora anexada. Dois arranjos experimentais foram desenvolvidos: um para medições utilizando uma lâmpada LED, e outra montagem utilizando uma lâmpada de xenônio. Com a análise comparativa evidenciou-se o impacto da utilização da cúpula difusora, a qual possibilitou que algumas das combinações dispositivo/aplicativo alcançassem desempenho adequado para sua aplicação na avaliação quotidiana de iluminância.[en] The illuminance of the environment has a physiological, emotional and productivity impact, depending on the activities that individuals are performing. International technical standards, such as ISO 8995-1: 2002 (CIE S 008 / E: 2001), also adopted in Brazil by ABNT, present requirements for the levels of illuminance existing in indoor environments in order to guarantee safety, comfort and efficiency in visual tasks throughout a work period. Measuring instruments such as luxmeters, are not used in everyday life. However, the possibility that the existing sensors in mobile devices can perform these measurements of illuminance will make its application viable in the daily life of the user, allowing to evaluate the adequacy of this greatness during his daily activities. Preliminary results available in the literature, comparing the performance of mobile devices associated with different applications in relation to the measurement results provided by a luxmeter, point to the inadequacy of the response of the mobile devices. On the other hand, it is possible that the use of a diffuser dome coupled to the mobile device may impact its performance to enable the application in the illuminance measurement. Thus, in this work are carried out studies to analyze the reliability of the illuminance values obtained by sensors already existing in smartphones and tablets, using or not a dome diffuser. The measurements were made using as reference, a digital luxmeter, and a set of mobile or tablet devices associated with different applications, in situations with and without diffuser dome attached. Two experimental arrangements were developed: one for measurements using a LED lamp, and another assembly using a xenon lamp. With the comparative analysis, the impact of the use of the diffusion dome was evidenced. The attachment of the dome enabled some of the device/application combinations to achieve adequate performance for application in the daily assessment of illuminance.MAXWELLELISABETH COSTA MONTEIRO2019-01-31TEXTOhttp://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=36378@1http://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=36378@2http://doi.org/10.17771/PUCRio.acad.36378pt