Optimization and Thermodynamic Performance Measures of a Class of Finite Time Thermodynamic Cycles

Modifications to the quasistatic Carnot cycle are developed in order to formulate improved theoretical bounds on the thermal efficiency of certain refrigeration cycles that produce finite cooling power. The modified refrigeration cycle is based on the idealized endoreversible finite time cycle. Two...

Full description

Bibliographic Details
Main Author: Walters, Joseph D.
Format: Others
Published: PDXScholar 1990
Subjects:
Online Access:https://pdxscholar.library.pdx.edu/open_access_etds/1186
https://pdxscholar.library.pdx.edu/cgi/viewcontent.cgi?article=2185&context=open_access_etds
id ndltd-pdx.edu-oai-pdxscholar.library.pdx.edu-open_access_etds-2185
record_format oai_dc
spelling ndltd-pdx.edu-oai-pdxscholar.library.pdx.edu-open_access_etds-21852019-10-20T04:39:14Z Optimization and Thermodynamic Performance Measures of a Class of Finite Time Thermodynamic Cycles Walters, Joseph D. Modifications to the quasistatic Carnot cycle are developed in order to formulate improved theoretical bounds on the thermal efficiency of certain refrigeration cycles that produce finite cooling power. The modified refrigeration cycle is based on the idealized endoreversible finite time cycle. Two of the four cycle branches are reversible adiabats, and the other two are the high and low temperature branches along which finite heat fluxes couple the refrigeration cycle with external heat reservoirs. This finite time model has been used to obtain the following results: First, the performance of a finite time Carnot refrigeration cycle (FTCRC) is examined. In the special case of equal heat transfer coefficients along heat transfer branches, it is found that by optimizing the FTCRC to maximize thermal efficiency and then evaluating the efficiency at peak cooling power, a new bound on the thermal efficiency of certain refrigeration cycles is given by $\epsilon\sb{m} = (\tilde\tau\sp2\sb{m}\ (T\sb{H}/T\sb{L}) - 1)\sp{-1},$ where $T\sb{H}$ and $T\sb{L}$ are the absolute high and low temperatures of the heat reservoirs, respectively, and $\tilde\tau\sb{m}=\sqrt{2}$ + 1 $\simeq$ 2.41 is the dimensionless cycle period at maximum cooling power. Second, a finite time refrigeration cycle (FTRC) is optimized to obtain four distinct optimal cycling modes that maximize efficiency and cooling power, and minimize power consumption and irreversible entropy production. It is found that to first order in cycling frequency and in the special symmetric case, the maximum efficiency and minimum irreversible entropy production modes are equally efficient. Additionally, simple analytic expressions are obtained for efficiencies at maximum cooling power within each optimal mode. Under certain limiting conditions the bounding efficiency at maximum cooling power shown above is obtained. Third, the problem of imperfect heat switches linking the working fluid of an FTRC to external heat reservoirs is studied. The maximum efficiency cycling mode is obtained by numerically optimizing the FTRC. Two distinct optimum cycling conditions exist: (1) operation at the global maximum in efficiency, and (2) operation at the frequency of maximum cooling power. The efficiency evaluated at maximum cooling power, and the global maximum efficiency may provide improved bench-mark bounds on thermal efficiencies of certain real irreversible refrigeration cycles. 1990-01-01T08:00:00Z text application/pdf https://pdxscholar.library.pdx.edu/open_access_etds/1186 https://pdxscholar.library.pdx.edu/cgi/viewcontent.cgi?article=2185&context=open_access_etds Dissertations and Theses PDXScholar Refrigeration and refrigerating machinery -- Thermodynamics -- Mathematic models Physics
collection NDLTD
format Others
sources NDLTD
topic Refrigeration and refrigerating machinery -- Thermodynamics -- Mathematic models
Physics
spellingShingle Refrigeration and refrigerating machinery -- Thermodynamics -- Mathematic models
Physics
Walters, Joseph D.
Optimization and Thermodynamic Performance Measures of a Class of Finite Time Thermodynamic Cycles
description Modifications to the quasistatic Carnot cycle are developed in order to formulate improved theoretical bounds on the thermal efficiency of certain refrigeration cycles that produce finite cooling power. The modified refrigeration cycle is based on the idealized endoreversible finite time cycle. Two of the four cycle branches are reversible adiabats, and the other two are the high and low temperature branches along which finite heat fluxes couple the refrigeration cycle with external heat reservoirs. This finite time model has been used to obtain the following results: First, the performance of a finite time Carnot refrigeration cycle (FTCRC) is examined. In the special case of equal heat transfer coefficients along heat transfer branches, it is found that by optimizing the FTCRC to maximize thermal efficiency and then evaluating the efficiency at peak cooling power, a new bound on the thermal efficiency of certain refrigeration cycles is given by $\epsilon\sb{m} = (\tilde\tau\sp2\sb{m}\ (T\sb{H}/T\sb{L}) - 1)\sp{-1},$ where $T\sb{H}$ and $T\sb{L}$ are the absolute high and low temperatures of the heat reservoirs, respectively, and $\tilde\tau\sb{m}=\sqrt{2}$ + 1 $\simeq$ 2.41 is the dimensionless cycle period at maximum cooling power. Second, a finite time refrigeration cycle (FTRC) is optimized to obtain four distinct optimal cycling modes that maximize efficiency and cooling power, and minimize power consumption and irreversible entropy production. It is found that to first order in cycling frequency and in the special symmetric case, the maximum efficiency and minimum irreversible entropy production modes are equally efficient. Additionally, simple analytic expressions are obtained for efficiencies at maximum cooling power within each optimal mode. Under certain limiting conditions the bounding efficiency at maximum cooling power shown above is obtained. Third, the problem of imperfect heat switches linking the working fluid of an FTRC to external heat reservoirs is studied. The maximum efficiency cycling mode is obtained by numerically optimizing the FTRC. Two distinct optimum cycling conditions exist: (1) operation at the global maximum in efficiency, and (2) operation at the frequency of maximum cooling power. The efficiency evaluated at maximum cooling power, and the global maximum efficiency may provide improved bench-mark bounds on thermal efficiencies of certain real irreversible refrigeration cycles.
author Walters, Joseph D.
author_facet Walters, Joseph D.
author_sort Walters, Joseph D.
title Optimization and Thermodynamic Performance Measures of a Class of Finite Time Thermodynamic Cycles
title_short Optimization and Thermodynamic Performance Measures of a Class of Finite Time Thermodynamic Cycles
title_full Optimization and Thermodynamic Performance Measures of a Class of Finite Time Thermodynamic Cycles
title_fullStr Optimization and Thermodynamic Performance Measures of a Class of Finite Time Thermodynamic Cycles
title_full_unstemmed Optimization and Thermodynamic Performance Measures of a Class of Finite Time Thermodynamic Cycles
title_sort optimization and thermodynamic performance measures of a class of finite time thermodynamic cycles
publisher PDXScholar
publishDate 1990
url https://pdxscholar.library.pdx.edu/open_access_etds/1186
https://pdxscholar.library.pdx.edu/cgi/viewcontent.cgi?article=2185&context=open_access_etds
work_keys_str_mv AT waltersjosephd optimizationandthermodynamicperformancemeasuresofaclassoffinitetimethermodynamiccycles
_version_ 1719271223155752960