Separační vlastnosti klasických porézních kolon a povrchově porézních kolon v analýze ambroxolu a jeho tří nečistot

This work was focused on the comparison of the separation of ambroxol and its three impurities with a column contained fully porous particles (Acquity BEH Shield RP18) and with two core-shell columns (Kinetex EVO C18 a Kinetex C18). Different pH values of buffer (borate buffer with pH = 9.70 and a p...

Full description

Bibliographic Details
Main Author: Slováček, Jan
Other Authors: Kozlík, Petr
Format: Dissertation
Language:Czech
Published: 2016
Online Access:http://www.nusl.cz/ntk/nusl-343431
id ndltd-nusl.cz-oai-invenio.nusl.cz-343431
record_format oai_dc
spelling ndltd-nusl.cz-oai-invenio.nusl.cz-3434312021-03-29T05:12:42Z Separační vlastnosti klasických porézních kolon a povrchově porézních kolon v analýze ambroxolu a jeho tří nečistot Separation performance of columns packed with fully porous and superficially porous particles in analysis of ambroxol and its three impurities Slováček, Jan Kozlík, Petr Tirčová, Barbora This work was focused on the comparison of the separation of ambroxol and its three impurities with a column contained fully porous particles (Acquity BEH Shield RP18) and with two core-shell columns (Kinetex EVO C18 a Kinetex C18). Different pH values of buffer (borate buffer with pH = 9.70 and a phosphate buffer with pH = 7.00 and pH = 3.00) and different gradient programs were tested for separation of analytes. Compared to the column with fully porous particles (Acquity BEH Shield RP18), core-shell columns provided shorter analysis time. Lower backpressure and different selectivity depend on a separation system. The best separation conditions were obtained with the column containing fully porous particles (BEH Shield RP18) and gradient according to program Method 2 with the borate buffer. Analysis time was 10 minutes and the last peak had the retention time about 9 min. Autosampler was tempered at 10 ř C and injection volume was 2 μl. The column was tempered at 30 řC. Detection was set at wavelength of 247 nm. Component A contained 10 mM borate buffer with pH = 9.70 and component B was acetonitrile. The best separation was achieved by core-shell columns while phosphate buffer with pH = 7.00 was used. Higher efficiency, smaller peak widths and higher sensitivity were observed. Phosphate buffer... 2016 info:eu-repo/semantics/masterThesis http://www.nusl.cz/ntk/nusl-343431 cze info:eu-repo/semantics/restrictedAccess
collection NDLTD
language Czech
format Dissertation
sources NDLTD
description This work was focused on the comparison of the separation of ambroxol and its three impurities with a column contained fully porous particles (Acquity BEH Shield RP18) and with two core-shell columns (Kinetex EVO C18 a Kinetex C18). Different pH values of buffer (borate buffer with pH = 9.70 and a phosphate buffer with pH = 7.00 and pH = 3.00) and different gradient programs were tested for separation of analytes. Compared to the column with fully porous particles (Acquity BEH Shield RP18), core-shell columns provided shorter analysis time. Lower backpressure and different selectivity depend on a separation system. The best separation conditions were obtained with the column containing fully porous particles (BEH Shield RP18) and gradient according to program Method 2 with the borate buffer. Analysis time was 10 minutes and the last peak had the retention time about 9 min. Autosampler was tempered at 10 ř C and injection volume was 2 μl. The column was tempered at 30 řC. Detection was set at wavelength of 247 nm. Component A contained 10 mM borate buffer with pH = 9.70 and component B was acetonitrile. The best separation was achieved by core-shell columns while phosphate buffer with pH = 7.00 was used. Higher efficiency, smaller peak widths and higher sensitivity were observed. Phosphate buffer...
author2 Kozlík, Petr
author_facet Kozlík, Petr
Slováček, Jan
author Slováček, Jan
spellingShingle Slováček, Jan
Separační vlastnosti klasických porézních kolon a povrchově porézních kolon v analýze ambroxolu a jeho tří nečistot
author_sort Slováček, Jan
title Separační vlastnosti klasických porézních kolon a povrchově porézních kolon v analýze ambroxolu a jeho tří nečistot
title_short Separační vlastnosti klasických porézních kolon a povrchově porézních kolon v analýze ambroxolu a jeho tří nečistot
title_full Separační vlastnosti klasických porézních kolon a povrchově porézních kolon v analýze ambroxolu a jeho tří nečistot
title_fullStr Separační vlastnosti klasických porézních kolon a povrchově porézních kolon v analýze ambroxolu a jeho tří nečistot
title_full_unstemmed Separační vlastnosti klasických porézních kolon a povrchově porézních kolon v analýze ambroxolu a jeho tří nečistot
title_sort separační vlastnosti klasických porézních kolon a povrchově porézních kolon v analýze ambroxolu a jeho tří nečistot
publishDate 2016
url http://www.nusl.cz/ntk/nusl-343431
work_keys_str_mv AT slovacekjan separacnivlastnostiklasickychporeznichkolonapovrchoveporeznichkolonvanalyzeambroxoluajehotrinecistot
AT slovacekjan separationperformanceofcolumnspackedwithfullyporousandsuperficiallyporousparticlesinanalysisofambroxolanditsthreeimpurities
_version_ 1719389784810455040