Vztah mezi vlastnostmi tepen dolních končetin a aortální tuhostí a jejich vliv na kardiovaskulární riziko

The ratio of systolic blood pressure at the ankle to arm systolic pressure (ankle- brachial index - ABI) is used in the diagnosis of peripheral vascular disease. While its reduced value suggests obstruction of the arterial lumen, an abnormally elevated value is due to incompressibility of lower extr...

Full description

Bibliographic Details
Main Author: Wohlfahrt, Peter
Other Authors: Cífková, Renata
Format: Doctoral Thesis
Language:Czech
Published: 2014
Online Access:http://www.nusl.cz/ntk/nusl-338492
id ndltd-nusl.cz-oai-invenio.nusl.cz-338492
record_format oai_dc
spelling ndltd-nusl.cz-oai-invenio.nusl.cz-3384922018-10-03T04:29:48Z Vztah mezi vlastnostmi tepen dolních končetin a aortální tuhostí a jejich vliv na kardiovaskulární riziko The relationship between lower extremity arterial properties and aortic stiffness and their effect on cardiovascular risk Wohlfahrt, Peter Cífková, Renata Karetová, Debora Bulvas, Miroslav The ratio of systolic blood pressure at the ankle to arm systolic pressure (ankle- brachial index - ABI) is used in the diagnosis of peripheral vascular disease. While its reduced value suggests obstruction of the arterial lumen, an abnormally elevated value is due to incompressibility of lower extremity arteries. While increased stiffness of the aorta, measured as carotid-femoral pulse wave velocity, is able to predict cardiovascular risk, increased pulse wave velocity of the leg arteries has no independent predictive value. Despite that, incompressibility of lower extremity arteries, diagnosed using ABI measurement, is independently associated with increased cardiovascular risk. The aim of our study was to determine the relationship between the characteristics of lower limb arteries and aortic stiffness, and their impact on cardiovascular risk. Our study showed that the results of oscillometric and Doppler ABI measurement methods are not interchangeable, because the oscillometric method systematically overestimates low values and underestimates high ABI values. Therefore, the diagnosis of lower limb arteries incompressibility should be based on the Doppler method of ABI measurement. Furthermore, we showed that age and cardiovascular risk factors have only a small effect on lower extremity arteries, but a... 2014 info:eu-repo/semantics/doctoralThesis http://www.nusl.cz/ntk/nusl-338492 cze info:eu-repo/semantics/restrictedAccess
collection NDLTD
language Czech
format Doctoral Thesis
sources NDLTD
description The ratio of systolic blood pressure at the ankle to arm systolic pressure (ankle- brachial index - ABI) is used in the diagnosis of peripheral vascular disease. While its reduced value suggests obstruction of the arterial lumen, an abnormally elevated value is due to incompressibility of lower extremity arteries. While increased stiffness of the aorta, measured as carotid-femoral pulse wave velocity, is able to predict cardiovascular risk, increased pulse wave velocity of the leg arteries has no independent predictive value. Despite that, incompressibility of lower extremity arteries, diagnosed using ABI measurement, is independently associated with increased cardiovascular risk. The aim of our study was to determine the relationship between the characteristics of lower limb arteries and aortic stiffness, and their impact on cardiovascular risk. Our study showed that the results of oscillometric and Doppler ABI measurement methods are not interchangeable, because the oscillometric method systematically overestimates low values and underestimates high ABI values. Therefore, the diagnosis of lower limb arteries incompressibility should be based on the Doppler method of ABI measurement. Furthermore, we showed that age and cardiovascular risk factors have only a small effect on lower extremity arteries, but a...
author2 Cífková, Renata
author_facet Cífková, Renata
Wohlfahrt, Peter
author Wohlfahrt, Peter
spellingShingle Wohlfahrt, Peter
Vztah mezi vlastnostmi tepen dolních končetin a aortální tuhostí a jejich vliv na kardiovaskulární riziko
author_sort Wohlfahrt, Peter
title Vztah mezi vlastnostmi tepen dolních končetin a aortální tuhostí a jejich vliv na kardiovaskulární riziko
title_short Vztah mezi vlastnostmi tepen dolních končetin a aortální tuhostí a jejich vliv na kardiovaskulární riziko
title_full Vztah mezi vlastnostmi tepen dolních končetin a aortální tuhostí a jejich vliv na kardiovaskulární riziko
title_fullStr Vztah mezi vlastnostmi tepen dolních končetin a aortální tuhostí a jejich vliv na kardiovaskulární riziko
title_full_unstemmed Vztah mezi vlastnostmi tepen dolních končetin a aortální tuhostí a jejich vliv na kardiovaskulární riziko
title_sort vztah mezi vlastnostmi tepen dolních končetin a aortální tuhostí a jejich vliv na kardiovaskulární riziko
publishDate 2014
url http://www.nusl.cz/ntk/nusl-338492
work_keys_str_mv AT wohlfahrtpeter vztahmezivlastnostmitependolnichkoncetinaaortalnituhostiajejichvlivnakardiovaskularniriziko
AT wohlfahrtpeter therelationshipbetweenlowerextremityarterialpropertiesandaorticstiffnessandtheireffectoncardiovascularrisk
_version_ 1718759184955080704