Využití systému přepínání kolon v HPLC pro stanovení vybraných mykotoxinů ve vzorcích piva na českém trhu
Charles University in Prague Faculty of Pharmacy in Hradec Králové Department of Analytical Chemistry Candidate: Ivona Lhotská Supervisor, consultant: María Carolina Fernández Ramos, Ph.D, Doc. RNDr. Dalibor Šatínský, Ph.D. Title of Diploma Thesis: Column switching chromatography for mycotoxines det...
Main Author: | |
---|---|
Other Authors: | |
Format: | Dissertation |
Language: | Czech |
Published: |
2014
|
Online Access: | http://www.nusl.cz/ntk/nusl-337308 |
id |
ndltd-nusl.cz-oai-invenio.nusl.cz-337308 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-nusl.cz-oai-invenio.nusl.cz-3373082021-03-29T05:12:41Z Využití systému přepínání kolon v HPLC pro stanovení vybraných mykotoxinů ve vzorcích piva na českém trhu Column switching chromatography for mycotoxines determination in Czech beer samples Lhotská, Ivona Ramos, María Carolina Fernández Chocholoušová Havlíková, Lucie Charles University in Prague Faculty of Pharmacy in Hradec Králové Department of Analytical Chemistry Candidate: Ivona Lhotská Supervisor, consultant: María Carolina Fernández Ramos, Ph.D, Doc. RNDr. Dalibor Šatínský, Ph.D. Title of Diploma Thesis: Column switching chromatography for mycotoxines determination in Czech beer samples A new fast and sensitive method of high performance liquid chromatography for simultaneous determination of mycotoxins ochratoxin A and citrinin using column- switching system for on-line sample pretreatment was developed. 100 µl of beer was injected directly into the chromatographic system. Isolation of analytes was performed on guard column Ascentis Express RP-C18 (5 x 4.6 mm, 2.7 µm) washing out with methanol - water solution of acetic acid 0.5% (30:70, v/v), at a flow rate 2 ml/min; time of valve switch was set on 2 minutes. The separation was performed on Ascentis Express Phenyl-Hexyl column (100 x 4.6 mm, 2.7 µm) with mobile phase of composition acetonitril - water solution of acetic acid 0.5% at a flow rate 1 ml/min. A gradient was increasing up to 75:25 linearly in time 3 - 5.5 min. The temperature 50řC was set up for column separation. Wavelengths of fluorimetric detection were set at Ex 335 nm, Em 497 nm. Analysis of one sample including on-line pretreatment was... 2014 info:eu-repo/semantics/masterThesis http://www.nusl.cz/ntk/nusl-337308 cze info:eu-repo/semantics/restrictedAccess |
collection |
NDLTD |
language |
Czech |
format |
Dissertation |
sources |
NDLTD |
description |
Charles University in Prague Faculty of Pharmacy in Hradec Králové Department of Analytical Chemistry Candidate: Ivona Lhotská Supervisor, consultant: María Carolina Fernández Ramos, Ph.D, Doc. RNDr. Dalibor Šatínský, Ph.D. Title of Diploma Thesis: Column switching chromatography for mycotoxines determination in Czech beer samples A new fast and sensitive method of high performance liquid chromatography for simultaneous determination of mycotoxins ochratoxin A and citrinin using column- switching system for on-line sample pretreatment was developed. 100 µl of beer was injected directly into the chromatographic system. Isolation of analytes was performed on guard column Ascentis Express RP-C18 (5 x 4.6 mm, 2.7 µm) washing out with methanol - water solution of acetic acid 0.5% (30:70, v/v), at a flow rate 2 ml/min; time of valve switch was set on 2 minutes. The separation was performed on Ascentis Express Phenyl-Hexyl column (100 x 4.6 mm, 2.7 µm) with mobile phase of composition acetonitril - water solution of acetic acid 0.5% at a flow rate 1 ml/min. A gradient was increasing up to 75:25 linearly in time 3 - 5.5 min. The temperature 50řC was set up for column separation. Wavelengths of fluorimetric detection were set at Ex 335 nm, Em 497 nm. Analysis of one sample including on-line pretreatment was... |
author2 |
Ramos, María Carolina Fernández |
author_facet |
Ramos, María Carolina Fernández Lhotská, Ivona |
author |
Lhotská, Ivona |
spellingShingle |
Lhotská, Ivona Využití systému přepínání kolon v HPLC pro stanovení vybraných mykotoxinů ve vzorcích piva na českém trhu |
author_sort |
Lhotská, Ivona |
title |
Využití systému přepínání kolon v HPLC pro stanovení vybraných mykotoxinů ve vzorcích piva na českém trhu |
title_short |
Využití systému přepínání kolon v HPLC pro stanovení vybraných mykotoxinů ve vzorcích piva na českém trhu |
title_full |
Využití systému přepínání kolon v HPLC pro stanovení vybraných mykotoxinů ve vzorcích piva na českém trhu |
title_fullStr |
Využití systému přepínání kolon v HPLC pro stanovení vybraných mykotoxinů ve vzorcích piva na českém trhu |
title_full_unstemmed |
Využití systému přepínání kolon v HPLC pro stanovení vybraných mykotoxinů ve vzorcích piva na českém trhu |
title_sort |
využití systému přepínání kolon v hplc pro stanovení vybraných mykotoxinů ve vzorcích piva na českém trhu |
publishDate |
2014 |
url |
http://www.nusl.cz/ntk/nusl-337308 |
work_keys_str_mv |
AT lhotskaivona vyuzitisystemuprepinanikolonvhplcprostanovenivybranychmykotoxinuvevzorcichpivanaceskemtrhu AT lhotskaivona columnswitchingchromatographyformycotoxinesdeterminationinczechbeersamples |
_version_ |
1719389673470558208 |