TEM aplikátor pro mikrovlnnou hypertermii
In my study is designed, realizated and tested microwave applicator with TEM wave to be used for local microwave treatment. Applicator is determined for hypertheia system LUND 1040. Working frequency is 434 MHz and dimension of aperture is 100 x 75 mm. For optimization of the discused applicator SEM...
Main Author: | |
---|---|
Other Authors: | |
Format: | Dissertation |
Language: | Czech |
Published: |
2011
|
Online Access: | http://www.nusl.cz/ntk/nusl-298827 |
id |
ndltd-nusl.cz-oai-invenio.nusl.cz-298827 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-nusl.cz-oai-invenio.nusl.cz-2988272017-06-27T04:42:50Z TEM aplikátor pro mikrovlnnou hypertermii TEM aplicator for microwave hypertermia Procházka, Miroslav Vrba, Jan Herza, Jan In my study is designed, realizated and tested microwave applicator with TEM wave to be used for local microwave treatment. Applicator is determined for hypertheia system LUND 1040. Working frequency is 434 MHz and dimension of aperture is 100 x 75 mm. For optimization of the discused applicator SEMCAD EM Simulator. Effective area of tretament of by me designed applicator is 55%. It is better of more than 15% in comparison with conventional waveguide applicators.Applicator has been found conveniet for patient treatment. 2011 info:eu-repo/semantics/masterThesis http://www.nusl.cz/ntk/nusl-298827 cze info:eu-repo/semantics/restrictedAccess |
collection |
NDLTD |
language |
Czech |
format |
Dissertation |
sources |
NDLTD |
description |
In my study is designed, realizated and tested microwave applicator with TEM wave to be used for local microwave treatment. Applicator is determined for hypertheia system LUND 1040. Working frequency is 434 MHz and dimension of aperture is 100 x 75 mm. For optimization of the discused applicator SEMCAD EM Simulator. Effective area of tretament of by me designed applicator is 55%. It is better of more than 15% in comparison with conventional waveguide applicators.Applicator has been found conveniet for patient treatment. |
author2 |
Vrba, Jan |
author_facet |
Vrba, Jan Procházka, Miroslav |
author |
Procházka, Miroslav |
spellingShingle |
Procházka, Miroslav TEM aplikátor pro mikrovlnnou hypertermii |
author_sort |
Procházka, Miroslav |
title |
TEM aplikátor pro mikrovlnnou hypertermii |
title_short |
TEM aplikátor pro mikrovlnnou hypertermii |
title_full |
TEM aplikátor pro mikrovlnnou hypertermii |
title_fullStr |
TEM aplikátor pro mikrovlnnou hypertermii |
title_full_unstemmed |
TEM aplikátor pro mikrovlnnou hypertermii |
title_sort |
tem aplikátor pro mikrovlnnou hypertermii |
publishDate |
2011 |
url |
http://www.nusl.cz/ntk/nusl-298827 |
work_keys_str_mv |
AT prochazkamiroslav temaplikatorpromikrovlnnouhypertermii AT prochazkamiroslav temaplicatorformicrowavehypertermia |
_version_ |
1718471461360893952 |