Srovnání submaximální zátěže na bicyklovém, klikovém a eliptickém ergometru

INTRODUCTION: This thesis is focused on comparison of submaximal load PWC 170 to three different types of cranks together with contrasting various methods of calculating this index. We have chosen one method from those four, which has seemed like having the least error and we have compared it agains...

Full description

Bibliographic Details
Main Author: Novoveská, Gabriela
Other Authors: Slabý, Kryštof
Format: Dissertation
Language:Czech
Published: 2011
Online Access:http://www.nusl.cz/ntk/nusl-297682
id ndltd-nusl.cz-oai-invenio.nusl.cz-297682
record_format oai_dc
spelling ndltd-nusl.cz-oai-invenio.nusl.cz-2976822017-06-27T04:42:32Z Srovnání submaximální zátěže na bicyklovém, klikovém a eliptickém ergometru The comparison of submaximal load on the bicacle ergometer, elliptical ergometer and arm crank Novoveská, Gabriela Slabý, Kryštof Machač, Stanislav INTRODUCTION: This thesis is focused on comparison of submaximal load PWC 170 to three different types of cranks together with contrasting various methods of calculating this index. We have chosen one method from those four, which has seemed like having the least error and we have compared it against those three remaining ones. METHODOLOGY: It has been tested on 10 probands (5 men and 5 women) which were in age range from 20 to 29 years and without any serious health problems. Graded test without breaks has been chosen for stress protocol, where every proband started with stress 1 W/kg of his weight on bycycle and eliptical crank. We have used conversion factor 0,5 on arm crank, which means that the stress on this crank started on 0,5 W/kg. The load has been gradually increasing by 0,5 W/kg on each level (0.25 W/kg on arm crank). Every level of load has three minutes duration and number of levels used has been individual because it has been driven by increase of pulse rate. After the proband has reached at least 170 beats per minute we have been continuously increasing the stress till we have reached maximum. We have determined pulse frequency during the examination on the end of each level of stress and also when the maximum has been reached, as well as subjective evaluation of load intensity on a... 2011 info:eu-repo/semantics/masterThesis http://www.nusl.cz/ntk/nusl-297682 cze info:eu-repo/semantics/restrictedAccess
collection NDLTD
language Czech
format Dissertation
sources NDLTD
description INTRODUCTION: This thesis is focused on comparison of submaximal load PWC 170 to three different types of cranks together with contrasting various methods of calculating this index. We have chosen one method from those four, which has seemed like having the least error and we have compared it against those three remaining ones. METHODOLOGY: It has been tested on 10 probands (5 men and 5 women) which were in age range from 20 to 29 years and without any serious health problems. Graded test without breaks has been chosen for stress protocol, where every proband started with stress 1 W/kg of his weight on bycycle and eliptical crank. We have used conversion factor 0,5 on arm crank, which means that the stress on this crank started on 0,5 W/kg. The load has been gradually increasing by 0,5 W/kg on each level (0.25 W/kg on arm crank). Every level of load has three minutes duration and number of levels used has been individual because it has been driven by increase of pulse rate. After the proband has reached at least 170 beats per minute we have been continuously increasing the stress till we have reached maximum. We have determined pulse frequency during the examination on the end of each level of stress and also when the maximum has been reached, as well as subjective evaluation of load intensity on a...
author2 Slabý, Kryštof
author_facet Slabý, Kryštof
Novoveská, Gabriela
author Novoveská, Gabriela
spellingShingle Novoveská, Gabriela
Srovnání submaximální zátěže na bicyklovém, klikovém a eliptickém ergometru
author_sort Novoveská, Gabriela
title Srovnání submaximální zátěže na bicyklovém, klikovém a eliptickém ergometru
title_short Srovnání submaximální zátěže na bicyklovém, klikovém a eliptickém ergometru
title_full Srovnání submaximální zátěže na bicyklovém, klikovém a eliptickém ergometru
title_fullStr Srovnání submaximální zátěže na bicyklovém, klikovém a eliptickém ergometru
title_full_unstemmed Srovnání submaximální zátěže na bicyklovém, klikovém a eliptickém ergometru
title_sort srovnání submaximální zátěže na bicyklovém, klikovém a eliptickém ergometru
publishDate 2011
url http://www.nusl.cz/ntk/nusl-297682
work_keys_str_mv AT novoveskagabriela srovnanisubmaximalnizatezenabicyklovemklikovemaeliptickemergometru
AT novoveskagabriela thecomparisonofsubmaximalloadonthebicacleergometerellipticalergometerandarmcrank
_version_ 1718471171202088960