Extrakce na tuhou fázi metodou Lab-On-Valve

Charles University in Prague Faculty of Pharmacy in Hradec Králové Department of Analytical chemistry Candidate: Lukáš Koblasa Supervisor: PharmDr. Petr Chocholouš, Ph.D. Title of diploma thesis: Solid phase extraction by method Lab-On-Valve This thesis deals with the development of method for direc...

Full description

Bibliographic Details
Main Author: Koblasa, Lukáš
Other Authors: Chocholouš, Petr
Format: Dissertation
Language:Czech
Published: 2011
Online Access:http://www.nusl.cz/ntk/nusl-297679
id ndltd-nusl.cz-oai-invenio.nusl.cz-297679
record_format oai_dc
spelling ndltd-nusl.cz-oai-invenio.nusl.cz-2976792017-06-27T04:42:32Z Extrakce na tuhou fázi metodou Lab-On-Valve Solid phase extraction by method Lab-On-Valve Koblasa, Lukáš Chocholouš, Petr Šatínský, Dalibor Charles University in Prague Faculty of Pharmacy in Hradec Králové Department of Analytical chemistry Candidate: Lukáš Koblasa Supervisor: PharmDr. Petr Chocholouš, Ph.D. Title of diploma thesis: Solid phase extraction by method Lab-On-Valve This thesis deals with the development of method for direct determination of potassium- saving diuretic amiloride in the urine sample by bead injection (BI) using Lab-on-Valve system (LOV). The determination was based on the selective capture of the amiloride on beads with sorbent (CM-Sephadex C-25 ion-exchange), while the possible interfering urine components were flushed into the waste stream of carrier. After preconcentration amiloride was eluted from the beads by eluent solution (0.25 M HNO3 + 0.05 M KCl), with flow rate of 5 µl/s. Detection was carried out a fluorescence spectrometer at a wavelength of 272 nm. Urine was diluted ten times and spiked by amiloride. For one analysis it was necessary to take 300 µl of the sample. Linearity of response was in the range of concentrations from 0.2 to 10.00 µg/ml (r = 0.990). The limit of detection (LOD) corresponds to a concentration of 0.05 mg / ml. The whole analysis lasted 280 seconds. 2011 info:eu-repo/semantics/masterThesis http://www.nusl.cz/ntk/nusl-297679 cze info:eu-repo/semantics/restrictedAccess
collection NDLTD
language Czech
format Dissertation
sources NDLTD
description Charles University in Prague Faculty of Pharmacy in Hradec Králové Department of Analytical chemistry Candidate: Lukáš Koblasa Supervisor: PharmDr. Petr Chocholouš, Ph.D. Title of diploma thesis: Solid phase extraction by method Lab-On-Valve This thesis deals with the development of method for direct determination of potassium- saving diuretic amiloride in the urine sample by bead injection (BI) using Lab-on-Valve system (LOV). The determination was based on the selective capture of the amiloride on beads with sorbent (CM-Sephadex C-25 ion-exchange), while the possible interfering urine components were flushed into the waste stream of carrier. After preconcentration amiloride was eluted from the beads by eluent solution (0.25 M HNO3 + 0.05 M KCl), with flow rate of 5 µl/s. Detection was carried out a fluorescence spectrometer at a wavelength of 272 nm. Urine was diluted ten times and spiked by amiloride. For one analysis it was necessary to take 300 µl of the sample. Linearity of response was in the range of concentrations from 0.2 to 10.00 µg/ml (r = 0.990). The limit of detection (LOD) corresponds to a concentration of 0.05 mg / ml. The whole analysis lasted 280 seconds.
author2 Chocholouš, Petr
author_facet Chocholouš, Petr
Koblasa, Lukáš
author Koblasa, Lukáš
spellingShingle Koblasa, Lukáš
Extrakce na tuhou fázi metodou Lab-On-Valve
author_sort Koblasa, Lukáš
title Extrakce na tuhou fázi metodou Lab-On-Valve
title_short Extrakce na tuhou fázi metodou Lab-On-Valve
title_full Extrakce na tuhou fázi metodou Lab-On-Valve
title_fullStr Extrakce na tuhou fázi metodou Lab-On-Valve
title_full_unstemmed Extrakce na tuhou fázi metodou Lab-On-Valve
title_sort extrakce na tuhou fázi metodou lab-on-valve
publishDate 2011
url http://www.nusl.cz/ntk/nusl-297679
work_keys_str_mv AT koblasalukas extrakcenatuhoufazimetodoulabonvalve
AT koblasalukas solidphaseextractionbymethodlabonvalve
_version_ 1718471169925971968