Elektroforetické stanovení vybraných myorelaxancií s využitím bezkontaktní vodivostní detekce

A novel capillary electrophoretic method for the separation of pancuronium (PM) and vecuronium (VM) ions utilizing capacitively coupled contactless conductivity detection (C4 D) was devised and validated. The separation was carried out in bare fused-silica capillaries (50 µm i.d., 75/45 cm) at 25 řC...

Full description

Bibliographic Details
Main Author: Lužová, Veronika
Other Authors: Polášek, Miroslav
Format: Dissertation
Language:Czech
Published: 2011
Online Access:http://www.nusl.cz/ntk/nusl-295995
id ndltd-nusl.cz-oai-invenio.nusl.cz-295995
record_format oai_dc
spelling ndltd-nusl.cz-oai-invenio.nusl.cz-2959952017-06-27T04:42:19Z Elektroforetické stanovení vybraných myorelaxancií s využitím bezkontaktní vodivostní detekce Electrophoretic determination of selected muscle relaxants using contactless conductivity detection Lužová, Veronika Polášek, Miroslav Pospíšilová, Marie A novel capillary electrophoretic method for the separation of pancuronium (PM) and vecuronium (VM) ions utilizing capacitively coupled contactless conductivity detection (C4 D) was devised and validated. The separation was carried out in bare fused-silica capillaries (50 µm i.d., 75/45 cm) at 25 řC. Optimal background electrolyte was 50 mM borate buffer of pH 9.5 containing 12.5 mg/ml of hydoxypropyl-γ-cyclodextrine; (phenyltrimethylammonium iodide was used as internal standard). The samples were injected hydrodynamically at 1000 mbar for 3 s. The separation was performed at +30 kV. Under such conditions the PM and VM were base-line resolved and the separation took < 4 min. Calibration curves were linear for both PM bromide and VM bromide in the range 25-250 μg/ml with r > 0.9968. The limits of detection were 7 and 6 μg/ml for PM bromide and VM bromide, respectively. The accuracy tested by recovery experiment at three concentration levels of added PM bromide and VM bromide was satisfactory (95.7-102.7 %, n=3, with RSD < 2.61 %). The method was successfully applied to the assay of PM bromide and VM bromide in commercial injection solutions. 2011 info:eu-repo/semantics/masterThesis http://www.nusl.cz/ntk/nusl-295995 cze info:eu-repo/semantics/restrictedAccess
collection NDLTD
language Czech
format Dissertation
sources NDLTD
description A novel capillary electrophoretic method for the separation of pancuronium (PM) and vecuronium (VM) ions utilizing capacitively coupled contactless conductivity detection (C4 D) was devised and validated. The separation was carried out in bare fused-silica capillaries (50 µm i.d., 75/45 cm) at 25 řC. Optimal background electrolyte was 50 mM borate buffer of pH 9.5 containing 12.5 mg/ml of hydoxypropyl-γ-cyclodextrine; (phenyltrimethylammonium iodide was used as internal standard). The samples were injected hydrodynamically at 1000 mbar for 3 s. The separation was performed at +30 kV. Under such conditions the PM and VM were base-line resolved and the separation took < 4 min. Calibration curves were linear for both PM bromide and VM bromide in the range 25-250 μg/ml with r > 0.9968. The limits of detection were 7 and 6 μg/ml for PM bromide and VM bromide, respectively. The accuracy tested by recovery experiment at three concentration levels of added PM bromide and VM bromide was satisfactory (95.7-102.7 %, n=3, with RSD < 2.61 %). The method was successfully applied to the assay of PM bromide and VM bromide in commercial injection solutions.
author2 Polášek, Miroslav
author_facet Polášek, Miroslav
Lužová, Veronika
author Lužová, Veronika
spellingShingle Lužová, Veronika
Elektroforetické stanovení vybraných myorelaxancií s využitím bezkontaktní vodivostní detekce
author_sort Lužová, Veronika
title Elektroforetické stanovení vybraných myorelaxancií s využitím bezkontaktní vodivostní detekce
title_short Elektroforetické stanovení vybraných myorelaxancií s využitím bezkontaktní vodivostní detekce
title_full Elektroforetické stanovení vybraných myorelaxancií s využitím bezkontaktní vodivostní detekce
title_fullStr Elektroforetické stanovení vybraných myorelaxancií s využitím bezkontaktní vodivostní detekce
title_full_unstemmed Elektroforetické stanovení vybraných myorelaxancií s využitím bezkontaktní vodivostní detekce
title_sort elektroforetické stanovení vybraných myorelaxancií s využitím bezkontaktní vodivostní detekce
publishDate 2011
url http://www.nusl.cz/ntk/nusl-295995
work_keys_str_mv AT luzovaveronika elektroforetickestanovenivybranychmyorelaxanciisvyuzitimbezkontaktnivodivostnidetekce
AT luzovaveronika electrophoreticdeterminationofselectedmusclerelaxantsusingcontactlessconductivitydetection
_version_ 1718470887208910848