Měření membránového potenciálu pomocí iontově-selektivních elektrod citlivých na tetrafenylfosfóniový kation

103 ABSTRACT The computerized device for membrane potential measurement using the tetraphenylphosphonium-selective electrode was constructed. Signal acquisition, processing and data storage were realized by MATLAB/Simulink software. The selective membrane was optimized incorporating TPP+ TPB- precip...

Full description

Bibliographic Details
Main Author: Lábajová, Anna
Other Authors: Kofránek, Jiří
Format: Doctoral Thesis
Language:Czech
Published: 2007
Online Access:http://www.nusl.cz/ntk/nusl-289773
id ndltd-nusl.cz-oai-invenio.nusl.cz-289773
record_format oai_dc
spelling ndltd-nusl.cz-oai-invenio.nusl.cz-2897732018-10-03T04:29:28Z Měření membránového potenciálu pomocí iontově-selektivních elektrod citlivých na tetrafenylfosfóniový kation Measurement of the membrane potential using ion-selective electrode sensitive to tetraphenylphosphonium Lábajová, Anna Kofránek, Jiří Sigler, Karel Plášek, Jaromír 103 ABSTRACT The computerized device for membrane potential measurement using the tetraphenylphosphonium-selective electrode was constructed. Signal acquisition, processing and data storage were realized by MATLAB/Simulink software. The selective membrane was optimized incorporating TPP+ TPB- precipitate into the membrane. The electrode had a Nernstian response from 3.10-6 M TPP+ . The TPP+ TPB- precipitate was later replaced by sodium tetrakis[3,5-bis(1,1,1,3,3,3-hexafluoro-2- methoxy-2-propyl)phenyl]borate (NaHFPB). The electrode with incorporated NaHFPB had a Nernstian response from 1.10-6 M TPP+ and had better sensitivity than commercially available electrodes. The values of selectivity coefficients for K+ , Na+ , Ca2+ and Mg2+ were calculated. The device was used for mitochondrial membrane potential measurement of isolated mitochondria and for evaluating the respiratory chain function of digitonin- permeabilized cells (hepatocytes, HeLa G, BSC-40 and control transmitochondrial cybrids). This method was used also for monitoring the mitochondrial permeability transition pore (MPTP) function of isolated mitochondria and permeabilized hepatocytes. MPTP opening was induced by high calcium concentration and the action of calcium was enhanced by pro-oxidant tert-butyl hydroperoxide (t-BHP). This... 2007 info:eu-repo/semantics/doctoralThesis http://www.nusl.cz/ntk/nusl-289773 cze info:eu-repo/semantics/restrictedAccess
collection NDLTD
language Czech
format Doctoral Thesis
sources NDLTD
description 103 ABSTRACT The computerized device for membrane potential measurement using the tetraphenylphosphonium-selective electrode was constructed. Signal acquisition, processing and data storage were realized by MATLAB/Simulink software. The selective membrane was optimized incorporating TPP+ TPB- precipitate into the membrane. The electrode had a Nernstian response from 3.10-6 M TPP+ . The TPP+ TPB- precipitate was later replaced by sodium tetrakis[3,5-bis(1,1,1,3,3,3-hexafluoro-2- methoxy-2-propyl)phenyl]borate (NaHFPB). The electrode with incorporated NaHFPB had a Nernstian response from 1.10-6 M TPP+ and had better sensitivity than commercially available electrodes. The values of selectivity coefficients for K+ , Na+ , Ca2+ and Mg2+ were calculated. The device was used for mitochondrial membrane potential measurement of isolated mitochondria and for evaluating the respiratory chain function of digitonin- permeabilized cells (hepatocytes, HeLa G, BSC-40 and control transmitochondrial cybrids). This method was used also for monitoring the mitochondrial permeability transition pore (MPTP) function of isolated mitochondria and permeabilized hepatocytes. MPTP opening was induced by high calcium concentration and the action of calcium was enhanced by pro-oxidant tert-butyl hydroperoxide (t-BHP). This...
author2 Kofránek, Jiří
author_facet Kofránek, Jiří
Lábajová, Anna
author Lábajová, Anna
spellingShingle Lábajová, Anna
Měření membránového potenciálu pomocí iontově-selektivních elektrod citlivých na tetrafenylfosfóniový kation
author_sort Lábajová, Anna
title Měření membránového potenciálu pomocí iontově-selektivních elektrod citlivých na tetrafenylfosfóniový kation
title_short Měření membránového potenciálu pomocí iontově-selektivních elektrod citlivých na tetrafenylfosfóniový kation
title_full Měření membránového potenciálu pomocí iontově-selektivních elektrod citlivých na tetrafenylfosfóniový kation
title_fullStr Měření membránového potenciálu pomocí iontově-selektivních elektrod citlivých na tetrafenylfosfóniový kation
title_full_unstemmed Měření membránového potenciálu pomocí iontově-selektivních elektrod citlivých na tetrafenylfosfóniový kation
title_sort měření membránového potenciálu pomocí iontově-selektivních elektrod citlivých na tetrafenylfosfóniový kation
publishDate 2007
url http://www.nusl.cz/ntk/nusl-289773
work_keys_str_mv AT labajovaanna merenimembranovehopotencialupomociiontoveselektivnichelektrodcitlivychnatetrafenylfosfoniovykation
AT labajovaanna measurementofthemembranepotentialusingionselectiveelectrodesensitivetotetraphenylphosphonium
_version_ 1718758992580182016