Měření membránového potenciálu pomocí iontově-selektivních elektrod citlivých na tetrafenylfosfóniový kation
103 ABSTRACT The computerized device for membrane potential measurement using the tetraphenylphosphonium-selective electrode was constructed. Signal acquisition, processing and data storage were realized by MATLAB/Simulink software. The selective membrane was optimized incorporating TPP+ TPB- precip...
Main Author: | |
---|---|
Other Authors: | |
Format: | Doctoral Thesis |
Language: | Czech |
Published: |
2007
|
Online Access: | http://www.nusl.cz/ntk/nusl-289773 |
id |
ndltd-nusl.cz-oai-invenio.nusl.cz-289773 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-nusl.cz-oai-invenio.nusl.cz-2897732018-10-03T04:29:28Z Měření membránového potenciálu pomocí iontově-selektivních elektrod citlivých na tetrafenylfosfóniový kation Measurement of the membrane potential using ion-selective electrode sensitive to tetraphenylphosphonium Lábajová, Anna Kofránek, Jiří Sigler, Karel Plášek, Jaromír 103 ABSTRACT The computerized device for membrane potential measurement using the tetraphenylphosphonium-selective electrode was constructed. Signal acquisition, processing and data storage were realized by MATLAB/Simulink software. The selective membrane was optimized incorporating TPP+ TPB- precipitate into the membrane. The electrode had a Nernstian response from 3.10-6 M TPP+ . The TPP+ TPB- precipitate was later replaced by sodium tetrakis[3,5-bis(1,1,1,3,3,3-hexafluoro-2- methoxy-2-propyl)phenyl]borate (NaHFPB). The electrode with incorporated NaHFPB had a Nernstian response from 1.10-6 M TPP+ and had better sensitivity than commercially available electrodes. The values of selectivity coefficients for K+ , Na+ , Ca2+ and Mg2+ were calculated. The device was used for mitochondrial membrane potential measurement of isolated mitochondria and for evaluating the respiratory chain function of digitonin- permeabilized cells (hepatocytes, HeLa G, BSC-40 and control transmitochondrial cybrids). This method was used also for monitoring the mitochondrial permeability transition pore (MPTP) function of isolated mitochondria and permeabilized hepatocytes. MPTP opening was induced by high calcium concentration and the action of calcium was enhanced by pro-oxidant tert-butyl hydroperoxide (t-BHP). This... 2007 info:eu-repo/semantics/doctoralThesis http://www.nusl.cz/ntk/nusl-289773 cze info:eu-repo/semantics/restrictedAccess |
collection |
NDLTD |
language |
Czech |
format |
Doctoral Thesis |
sources |
NDLTD |
description |
103 ABSTRACT The computerized device for membrane potential measurement using the tetraphenylphosphonium-selective electrode was constructed. Signal acquisition, processing and data storage were realized by MATLAB/Simulink software. The selective membrane was optimized incorporating TPP+ TPB- precipitate into the membrane. The electrode had a Nernstian response from 3.10-6 M TPP+ . The TPP+ TPB- precipitate was later replaced by sodium tetrakis[3,5-bis(1,1,1,3,3,3-hexafluoro-2- methoxy-2-propyl)phenyl]borate (NaHFPB). The electrode with incorporated NaHFPB had a Nernstian response from 1.10-6 M TPP+ and had better sensitivity than commercially available electrodes. The values of selectivity coefficients for K+ , Na+ , Ca2+ and Mg2+ were calculated. The device was used for mitochondrial membrane potential measurement of isolated mitochondria and for evaluating the respiratory chain function of digitonin- permeabilized cells (hepatocytes, HeLa G, BSC-40 and control transmitochondrial cybrids). This method was used also for monitoring the mitochondrial permeability transition pore (MPTP) function of isolated mitochondria and permeabilized hepatocytes. MPTP opening was induced by high calcium concentration and the action of calcium was enhanced by pro-oxidant tert-butyl hydroperoxide (t-BHP). This... |
author2 |
Kofránek, Jiří |
author_facet |
Kofránek, Jiří Lábajová, Anna |
author |
Lábajová, Anna |
spellingShingle |
Lábajová, Anna Měření membránového potenciálu pomocí iontově-selektivních elektrod citlivých na tetrafenylfosfóniový kation |
author_sort |
Lábajová, Anna |
title |
Měření membránového potenciálu pomocí iontově-selektivních elektrod citlivých na tetrafenylfosfóniový kation |
title_short |
Měření membránového potenciálu pomocí iontově-selektivních elektrod citlivých na tetrafenylfosfóniový kation |
title_full |
Měření membránového potenciálu pomocí iontově-selektivních elektrod citlivých na tetrafenylfosfóniový kation |
title_fullStr |
Měření membránového potenciálu pomocí iontově-selektivních elektrod citlivých na tetrafenylfosfóniový kation |
title_full_unstemmed |
Měření membránového potenciálu pomocí iontově-selektivních elektrod citlivých na tetrafenylfosfóniový kation |
title_sort |
měření membránového potenciálu pomocí iontově-selektivních elektrod citlivých na tetrafenylfosfóniový kation |
publishDate |
2007 |
url |
http://www.nusl.cz/ntk/nusl-289773 |
work_keys_str_mv |
AT labajovaanna merenimembranovehopotencialupomociiontoveselektivnichelektrodcitlivychnatetrafenylfosfoniovykation AT labajovaanna measurementofthemembranepotentialusingionselectiveelectrodesensitivetotetraphenylphosphonium |
_version_ |
1718758992580182016 |