Hodnocení opacit zadního pouzdra u různých typů nitroočních čoček

Purpose: To evaluate posterior capsule opacification (PCO) in patients 7 years after cataract operation with the implantation of three types of intraocular lenses (IOL): rigid polymethylmetacrylate IOL (PMMA) with a round optical edge, foldable hydrophobic acrylate IOL with a sharp edged optic and f...

Full description

Bibliographic Details
Main Author: Pozlerová, Jana
Other Authors: Jirásková, Naďa
Format: Doctoral Thesis
Language:Czech
Published: 2009
Online Access:http://www.nusl.cz/ntk/nusl-281031
id ndltd-nusl.cz-oai-invenio.nusl.cz-281031
record_format oai_dc
spelling ndltd-nusl.cz-oai-invenio.nusl.cz-2810312021-02-26T05:19:15Z Hodnocení opacit zadního pouzdra u různých typů nitroočních čoček EVALUATION OF POSTERIOR CAPSULE OPACIFICATION AMONG VARIOUS TYPES OF INTRAOCULAR LENS Pozlerová, Jana Jirásková, Naďa Těšínský, Pavel Synek, Svatopluk Purpose: To evaluate posterior capsule opacification (PCO) in patients 7 years after cataract operation with the implantation of three types of intraocular lenses (IOL): rigid polymethylmetacrylate IOL (PMMA) with a round optical edge, foldable hydrophobic acrylate IOL with a sharp edged optic and foldable IOL whose optical part is made from silicone with round edges. For the quantification, two computerized methods were used and the correlation of the two systems was evaluated. Data from both methods were used to compare PCO incidence for the followed IOL and ascertain if some type of IOL showed better qualifications in the prevention of posterior capsule opacification. Patients and methods: We evaluated 73 patients that had undergone cataract operation using the classic ultrasound phacoemulsification method in the time period of 1998-2000 at the Ophthalmology Department of the Hradec Kralove Faculty Hospital. Seven years after the operation, a standard ophthalmologic examination was performed including best corrected visual acuity (BCVA) and a digital photograph of the anterior segment of the eye in mydriasis, focusing on the posterior capsule. On the photograph, posterior capsule opacification were evaluated using the Evaluation of Posterior Capsule Opacification 2000 software (EPCO 2000) and the... 2009 info:eu-repo/semantics/doctoralThesis http://www.nusl.cz/ntk/nusl-281031 cze info:eu-repo/semantics/restrictedAccess
collection NDLTD
language Czech
format Doctoral Thesis
sources NDLTD
description Purpose: To evaluate posterior capsule opacification (PCO) in patients 7 years after cataract operation with the implantation of three types of intraocular lenses (IOL): rigid polymethylmetacrylate IOL (PMMA) with a round optical edge, foldable hydrophobic acrylate IOL with a sharp edged optic and foldable IOL whose optical part is made from silicone with round edges. For the quantification, two computerized methods were used and the correlation of the two systems was evaluated. Data from both methods were used to compare PCO incidence for the followed IOL and ascertain if some type of IOL showed better qualifications in the prevention of posterior capsule opacification. Patients and methods: We evaluated 73 patients that had undergone cataract operation using the classic ultrasound phacoemulsification method in the time period of 1998-2000 at the Ophthalmology Department of the Hradec Kralove Faculty Hospital. Seven years after the operation, a standard ophthalmologic examination was performed including best corrected visual acuity (BCVA) and a digital photograph of the anterior segment of the eye in mydriasis, focusing on the posterior capsule. On the photograph, posterior capsule opacification were evaluated using the Evaluation of Posterior Capsule Opacification 2000 software (EPCO 2000) and the...
author2 Jirásková, Naďa
author_facet Jirásková, Naďa
Pozlerová, Jana
author Pozlerová, Jana
spellingShingle Pozlerová, Jana
Hodnocení opacit zadního pouzdra u různých typů nitroočních čoček
author_sort Pozlerová, Jana
title Hodnocení opacit zadního pouzdra u různých typů nitroočních čoček
title_short Hodnocení opacit zadního pouzdra u různých typů nitroočních čoček
title_full Hodnocení opacit zadního pouzdra u různých typů nitroočních čoček
title_fullStr Hodnocení opacit zadního pouzdra u různých typů nitroočních čoček
title_full_unstemmed Hodnocení opacit zadního pouzdra u různých typů nitroočních čoček
title_sort hodnocení opacit zadního pouzdra u různých typů nitroočních čoček
publishDate 2009
url http://www.nusl.cz/ntk/nusl-281031
work_keys_str_mv AT pozlerovajana hodnoceniopacitzadnihopouzdrauruznychtypunitroocnichcocek
AT pozlerovajana evaluationofposteriorcapsuleopacificationamongvarioustypesofintraocularlens
_version_ 1719378924742377472