Polarimetric thermal imaging

Passive infrared (IR) imagers, using intensity contrast for target detection, are often limited by low target-background contrast. Detecting stationary targets against cluttered backgrounds presents an even bigger challenge. Polarized signatures can be used as an additional discriminator, to impro...

Full description

Bibliographic Details
Main Author: Loo, Fook Leong
Other Authors: Cooper, Alfred W.
Published: Monterey California. Naval Postgraduate School 2012
Online Access:http://hdl.handle.net/10945/3563
id ndltd-nps.edu-oai-calhoun.nps.edu-10945-3563
record_format oai_dc
spelling ndltd-nps.edu-oai-calhoun.nps.edu-10945-35632014-11-27T16:04:43Z Polarimetric thermal imaging Loo, Fook Leong Cooper, Alfred W. Karunasiri, Gamani Naval Postgraduate School (U.S.) Passive infrared (IR) imagers, using intensity contrast for target detection, are often limited by low target-background contrast. Detecting stationary targets against cluttered backgrounds presents an even bigger challenge. Polarized signatures can be used as an additional discriminator, to improve target detection probability and reduce false alarm rate. In this research, a polarmetric thermal imager, operating in the mid wave infrared (3-5 U), was set up using the Merlin InSb camera with three internal wire grid polarizers. Non uniformity correction and radiometric calibration were performed to compensate for differences in detector response and polarizer's transmittance. The scene consisted of a heated aluminum plate in front of a large area blackbody as background. The viewing angle, defined as the angle between surface normal and camera angle of sight, was varied by rotating the plate about its vertical axis. Stokes parameters were computed from the irradiance images. Images of intensity, degree of polarization and polarization angle were derived from the Stokes parameters. The dependence of these polarization characteristics on viewing angle was investigated. While intensity increased slightly with viewing angle, degree of polarization increased rapidly when the viewing angle was increased from 20 degrees to 80 degrees. The polarization angle increased with viewing angle and became constant at 150 degrees for viewing angle greater than 60 degrees. Target to background contrast based on degree of polarization increased with viewing angle and was higher than intensity contrast for viewing angle greater than 20 degrees. Image processing algorithms were developed to segment the target plate from its background. The target similarity metric used was the texture-based Fisher distance, which enabled the fusion of one or more data type. The performance of the fusion schemes was compared via their Receiver Opening Characteristic (ROC) curves, which were plots of segmentation accuracy against false alarm rate. Binary image of the target was obtained by applying a Constant False Alarm Rate (CFAR) threshold. Fusion of intensity and polarization data produced better segmentation accuracy and lower false alarm rate than intensity-only data, for plate at viewing angle greater than 60 degrees. 2012-03-14T17:38:44Z 2012-03-14T17:38:44Z 2007-03 Thesis http://hdl.handle.net/10945/3563 133185122 Approved for public release, distribution unlimited Monterey California. Naval Postgraduate School
collection NDLTD
sources NDLTD
description Passive infrared (IR) imagers, using intensity contrast for target detection, are often limited by low target-background contrast. Detecting stationary targets against cluttered backgrounds presents an even bigger challenge. Polarized signatures can be used as an additional discriminator, to improve target detection probability and reduce false alarm rate. In this research, a polarmetric thermal imager, operating in the mid wave infrared (3-5 U), was set up using the Merlin InSb camera with three internal wire grid polarizers. Non uniformity correction and radiometric calibration were performed to compensate for differences in detector response and polarizer's transmittance. The scene consisted of a heated aluminum plate in front of a large area blackbody as background. The viewing angle, defined as the angle between surface normal and camera angle of sight, was varied by rotating the plate about its vertical axis. Stokes parameters were computed from the irradiance images. Images of intensity, degree of polarization and polarization angle were derived from the Stokes parameters. The dependence of these polarization characteristics on viewing angle was investigated. While intensity increased slightly with viewing angle, degree of polarization increased rapidly when the viewing angle was increased from 20 degrees to 80 degrees. The polarization angle increased with viewing angle and became constant at 150 degrees for viewing angle greater than 60 degrees. Target to background contrast based on degree of polarization increased with viewing angle and was higher than intensity contrast for viewing angle greater than 20 degrees. Image processing algorithms were developed to segment the target plate from its background. The target similarity metric used was the texture-based Fisher distance, which enabled the fusion of one or more data type. The performance of the fusion schemes was compared via their Receiver Opening Characteristic (ROC) curves, which were plots of segmentation accuracy against false alarm rate. Binary image of the target was obtained by applying a Constant False Alarm Rate (CFAR) threshold. Fusion of intensity and polarization data produced better segmentation accuracy and lower false alarm rate than intensity-only data, for plate at viewing angle greater than 60 degrees.
author2 Cooper, Alfred W.
author_facet Cooper, Alfred W.
Loo, Fook Leong
author Loo, Fook Leong
spellingShingle Loo, Fook Leong
Polarimetric thermal imaging
author_sort Loo, Fook Leong
title Polarimetric thermal imaging
title_short Polarimetric thermal imaging
title_full Polarimetric thermal imaging
title_fullStr Polarimetric thermal imaging
title_full_unstemmed Polarimetric thermal imaging
title_sort polarimetric thermal imaging
publisher Monterey California. Naval Postgraduate School
publishDate 2012
url http://hdl.handle.net/10945/3563
work_keys_str_mv AT loofookleong polarimetricthermalimaging
_version_ 1716720794889879552