Push-pull test for in situ determination of microbial metabolic activities: denitrification and methanogenesis

CIVINS === Quantitative information on subsurface microbial processes is needed for many applications, but information obtained by existing methods can be difficult to interpret. The goal of this project was to develop a single well, 'push-pull' test for the determination of in situ microb...

Full description

Bibliographic Details
Main Author: Odenthal, Paul James.
Other Authors: Civil Engineering
Published: 2012
Online Access:http://hdl.handle.net/10945/24350
id ndltd-nps.edu-oai-calhoun.nps.edu-10945-24350
record_format oai_dc
spelling ndltd-nps.edu-oai-calhoun.nps.edu-10945-243502014-11-27T16:15:44Z Push-pull test for in situ determination of microbial metabolic activities: denitrification and methanogenesis Odenthal, Paul James. Civil Engineering CIVINS Quantitative information on subsurface microbial processes is needed for many applications, but information obtained by existing methods can be difficult to interpret. The goal of this project was to develop a single well, 'push-pull' test for the determination of in situ microbial metabolic activities. The method consists of an injection of a test solution into an existing monitoring well followed by the extraction of the groundwater/test solution mixture from the same well. The test solution consists of a tracer and one or more reactive solutes selected to investigate the activity of a specific microbial system. During the extraction phase, the concentrations of all components of the test solution and potential reaction products are measured and used to develop breakthrough curves. A series of tests were used to investigate the processes of denitrification and methanogenesis by injecting solutions with nitrate, nitrite, or dissolved hydrogen gas in a petroleum contaminated, anaerobic zone of an unconfined, alluvial aquifer and in an uncontaminated, aerobic zone of the same aquifer located directly upgradient of the contaminated zone. Nitrate and nitrite injections yielded utilization rates that were approximately 2.5 times greater in the contaminated zone (than in the uncontaminated zone) where 80% of the injected nitrate mass and 90% of the injected nitrite mass were utilized. During the nitrate injection tests, trace amounts of produced nitrite were detected. The hydrogen injection test resulted in a 60% loss of hydrogen with no detectable methane production in the contaminated well. The push-pull field procedure developed in this project was shown to be capable of determining and quantifying microbial metabolic activity in situ. 2012-12-13T18:44:05Z 2012-12-13T18:44:05Z 1995 Thesis http://hdl.handle.net/10945/24350 This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. As such, it is in the public domain, and under the provisions of Title 17, United States Code, Section 105, it may not be copyrighted.
collection NDLTD
sources NDLTD
description CIVINS === Quantitative information on subsurface microbial processes is needed for many applications, but information obtained by existing methods can be difficult to interpret. The goal of this project was to develop a single well, 'push-pull' test for the determination of in situ microbial metabolic activities. The method consists of an injection of a test solution into an existing monitoring well followed by the extraction of the groundwater/test solution mixture from the same well. The test solution consists of a tracer and one or more reactive solutes selected to investigate the activity of a specific microbial system. During the extraction phase, the concentrations of all components of the test solution and potential reaction products are measured and used to develop breakthrough curves. A series of tests were used to investigate the processes of denitrification and methanogenesis by injecting solutions with nitrate, nitrite, or dissolved hydrogen gas in a petroleum contaminated, anaerobic zone of an unconfined, alluvial aquifer and in an uncontaminated, aerobic zone of the same aquifer located directly upgradient of the contaminated zone. Nitrate and nitrite injections yielded utilization rates that were approximately 2.5 times greater in the contaminated zone (than in the uncontaminated zone) where 80% of the injected nitrate mass and 90% of the injected nitrite mass were utilized. During the nitrate injection tests, trace amounts of produced nitrite were detected. The hydrogen injection test resulted in a 60% loss of hydrogen with no detectable methane production in the contaminated well. The push-pull field procedure developed in this project was shown to be capable of determining and quantifying microbial metabolic activity in situ.
author2 Civil Engineering
author_facet Civil Engineering
Odenthal, Paul James.
author Odenthal, Paul James.
spellingShingle Odenthal, Paul James.
Push-pull test for in situ determination of microbial metabolic activities: denitrification and methanogenesis
author_sort Odenthal, Paul James.
title Push-pull test for in situ determination of microbial metabolic activities: denitrification and methanogenesis
title_short Push-pull test for in situ determination of microbial metabolic activities: denitrification and methanogenesis
title_full Push-pull test for in situ determination of microbial metabolic activities: denitrification and methanogenesis
title_fullStr Push-pull test for in situ determination of microbial metabolic activities: denitrification and methanogenesis
title_full_unstemmed Push-pull test for in situ determination of microbial metabolic activities: denitrification and methanogenesis
title_sort push-pull test for in situ determination of microbial metabolic activities: denitrification and methanogenesis
publishDate 2012
url http://hdl.handle.net/10945/24350
work_keys_str_mv AT odenthalpauljames pushpulltestforinsitudeterminationofmicrobialmetabolicactivitiesdenitrificationandmethanogenesis
_version_ 1716724478920097792