Low-cost flexible sensor glove as a rehabilitation and diagnostic tool

A dissertation submitted to the Faculty of Engineering and the Built Environment, University of the Witwatersrand, Johannesburg, in fulfilment of the requirements for the degree of Master of Science in Engineering, Johannesburg, April 2020 === Hand therapy for patients suffering with hand impairmen...

Full description

Bibliographic Details
Main Author: Indermun, Shival
Format: Others
Language:en
Published: 2020
Online Access:https://hdl.handle.net/10539/30108
id ndltd-netd.ac.za-oai-union.ndltd.org-wits-oai-wiredspace.wits.ac.za-10539-30108
record_format oai_dc
spelling ndltd-netd.ac.za-oai-union.ndltd.org-wits-oai-wiredspace.wits.ac.za-10539-301082021-06-29T05:15:37Z Low-cost flexible sensor glove as a rehabilitation and diagnostic tool Indermun, Shival A dissertation submitted to the Faculty of Engineering and the Built Environment, University of the Witwatersrand, Johannesburg, in fulfilment of the requirements for the degree of Master of Science in Engineering, Johannesburg, April 2020 Hand therapy for patients suffering with hand impairment, caused by physical injury or neurological disorders is often inaccessible to patients that live far away from local clinics. Apart from accessibility, developing countries face additional issues such as high patient referral rates and time limitations. Therefore, it is imperative that there are accessible and low-cost means for hand rehabilitation and impairment diagnosis. A low-cost flexible sensor was developed to measure the range of motion of the fingers for the application of rehabilitation in developing countries. Flexible sensors were attached to the proximal interphalangeal (PIP) and metacarpophalangeal (MCP) joints of the fingers and the interphalangeal (IP) joint of the thumb. The gloves were validated through testing each joint at 30, 45 and 60_ degrees. Fluctuations had a maximum variation of +/-5°. The glove measured the range of motion in 50 healthy subjects performing daily activities that were derived from the ICF(Inter- national Classication of Functioning, Disability and Health) guide. The testing was split into dynamic (10 participants) and static (40 participants) phases. There were no criteria for subject participation apart from the fit of the gloves. The gloves proved capable of measuring the range of motion of the finger joints. The IP join of the thumb had the most variation throughout the dynamic tests. The statictests resulted in a ROM of 39.88_-69.42_, 18.92_- 78.1_ and 13.42_-60.15_ for the MCP, PIP and IP joints, respectively. The data collected provided the range of motion required for an individual to perform activities of daily living and thus validating the gloves use as a_finger motion measurement tool. Therefore, the glove can be applied to monitoring patient recovery, hand impairment diagnosis and providing rehabilitation therapy. PH2020 2020-11-09T09:48:38Z 2020-11-09T09:48:38Z 2020-04 Thesis https://hdl.handle.net/10539/30108 en application/pdf
collection NDLTD
language en
format Others
sources NDLTD
description A dissertation submitted to the Faculty of Engineering and the Built Environment, University of the Witwatersrand, Johannesburg, in fulfilment of the requirements for the degree of Master of Science in Engineering, Johannesburg, April 2020 === Hand therapy for patients suffering with hand impairment, caused by physical injury or neurological disorders is often inaccessible to patients that live far away from local clinics. Apart from accessibility, developing countries face additional issues such as high patient referral rates and time limitations. Therefore, it is imperative that there are accessible and low-cost means for hand rehabilitation and impairment diagnosis. A low-cost flexible sensor was developed to measure the range of motion of the fingers for the application of rehabilitation in developing countries. Flexible sensors were attached to the proximal interphalangeal (PIP) and metacarpophalangeal (MCP) joints of the fingers and the interphalangeal (IP) joint of the thumb. The gloves were validated through testing each joint at 30, 45 and 60_ degrees. Fluctuations had a maximum variation of +/-5°. The glove measured the range of motion in 50 healthy subjects performing daily activities that were derived from the ICF(Inter- national Classication of Functioning, Disability and Health) guide. The testing was split into dynamic (10 participants) and static (40 participants) phases. There were no criteria for subject participation apart from the fit of the gloves. The gloves proved capable of measuring the range of motion of the finger joints. The IP join of the thumb had the most variation throughout the dynamic tests. The statictests resulted in a ROM of 39.88_-69.42_, 18.92_- 78.1_ and 13.42_-60.15_ for the MCP, PIP and IP joints, respectively. The data collected provided the range of motion required for an individual to perform activities of daily living and thus validating the gloves use as a_finger motion measurement tool. Therefore, the glove can be applied to monitoring patient recovery, hand impairment diagnosis and providing rehabilitation therapy. === PH2020
author Indermun, Shival
spellingShingle Indermun, Shival
Low-cost flexible sensor glove as a rehabilitation and diagnostic tool
author_facet Indermun, Shival
author_sort Indermun, Shival
title Low-cost flexible sensor glove as a rehabilitation and diagnostic tool
title_short Low-cost flexible sensor glove as a rehabilitation and diagnostic tool
title_full Low-cost flexible sensor glove as a rehabilitation and diagnostic tool
title_fullStr Low-cost flexible sensor glove as a rehabilitation and diagnostic tool
title_full_unstemmed Low-cost flexible sensor glove as a rehabilitation and diagnostic tool
title_sort low-cost flexible sensor glove as a rehabilitation and diagnostic tool
publishDate 2020
url https://hdl.handle.net/10539/30108
work_keys_str_mv AT indermunshival lowcostflexiblesensorgloveasarehabilitationanddiagnostictool
_version_ 1719414226377768960