An investigation into the shear bond strength of masonry

This study was undertaken to investigate the shear strength of masonry. Specimens were produced and tested. The failure mechanism, the peak shear strength as well as the force deflection curves for all specimens were recorded. The specimens failed at the shear bond eighty percent of the time. The...

Full description

Bibliographic Details
Main Author: Couroupis, Isidoros
Format: Others
Language:en
Published: 2015
Online Access:http://hdl.handle.net/10539/17547
id ndltd-netd.ac.za-oai-union.ndltd.org-wits-oai-wiredspace.wits.ac.za-10539-17547
record_format oai_dc
spelling ndltd-netd.ac.za-oai-union.ndltd.org-wits-oai-wiredspace.wits.ac.za-10539-175472021-04-29T05:09:16Z An investigation into the shear bond strength of masonry Couroupis, Isidoros This study was undertaken to investigate the shear strength of masonry. Specimens were produced and tested. The failure mechanism, the peak shear strength as well as the force deflection curves for all specimens were recorded. The specimens failed at the shear bond eighty percent of the time. The positions in a wall where the bricks are attached to the mortar when constructing the wall, produces a weaker brick mortar bond than, where the mortar is applied to the bricks. The characteristic shear strength equations obtained for a double and a single wall through experimentation, gives shear strength values respectively of 4.2 and 2.8 times greater than the recommended equations of the European and South African codes of masonry design. After 3 mm differential settlement, a wall has to be repaired due to the rapid increase in shear stresses. 2015-04-28T11:04:52Z 2015-04-28T11:04:52Z 2015-04-28 Thesis http://hdl.handle.net/10539/17547 en application/pdf application/pdf
collection NDLTD
language en
format Others
sources NDLTD
description This study was undertaken to investigate the shear strength of masonry. Specimens were produced and tested. The failure mechanism, the peak shear strength as well as the force deflection curves for all specimens were recorded. The specimens failed at the shear bond eighty percent of the time. The positions in a wall where the bricks are attached to the mortar when constructing the wall, produces a weaker brick mortar bond than, where the mortar is applied to the bricks. The characteristic shear strength equations obtained for a double and a single wall through experimentation, gives shear strength values respectively of 4.2 and 2.8 times greater than the recommended equations of the European and South African codes of masonry design. After 3 mm differential settlement, a wall has to be repaired due to the rapid increase in shear stresses.
author Couroupis, Isidoros
spellingShingle Couroupis, Isidoros
An investigation into the shear bond strength of masonry
author_facet Couroupis, Isidoros
author_sort Couroupis, Isidoros
title An investigation into the shear bond strength of masonry
title_short An investigation into the shear bond strength of masonry
title_full An investigation into the shear bond strength of masonry
title_fullStr An investigation into the shear bond strength of masonry
title_full_unstemmed An investigation into the shear bond strength of masonry
title_sort investigation into the shear bond strength of masonry
publishDate 2015
url http://hdl.handle.net/10539/17547
work_keys_str_mv AT couroupisisidoros aninvestigationintotheshearbondstrengthofmasonry
AT couroupisisidoros investigationintotheshearbondstrengthofmasonry
_version_ 1719399614405148672