A leak tight design methodology for large diameter flanges based on non-linear modelling and analysis
There is currently a need for large diameter flanges for the supply of water in South Africa. These large diameter pipe flanges are required to accommodate pipes with nominal bores of up to 4 m and should successfully withstand internal pressures of up to 8 MPa. No current relevant standard / code...
Main Author: | |
---|---|
Other Authors: | |
Language: | en |
Published: |
University of Pretoria
2016
|
Subjects: | |
Online Access: | http://hdl.handle.net/2263/56085 Luyt, ICB 2015, A leak tight design methodology for large diameter flanges based on non-linear modelling and analysis, MEng Dissertation, University of Pretoria, Pretoria, viewed yymmdd <http://hdl.handle.net/2263/56085> |
id |
ndltd-netd.ac.za-oai-union.ndltd.org-up-oai-repository.up.ac.za-2263-56085 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-netd.ac.za-oai-union.ndltd.org-up-oai-repository.up.ac.za-2263-560852020-06-02T03:18:33Z A leak tight design methodology for large diameter flanges based on non-linear modelling and analysis Luyt, Ian Christiaan Berning Theron, Nicolaas J. u28012942@tuks.co.za Pietra, F. UCTD There is currently a need for large diameter flanges for the supply of water in South Africa. These large diameter pipe flanges are required to accommodate pipes with nominal bores of up to 4 m and should successfully withstand internal pressures of up to 8 MPa. No current relevant standard / code contains prescribed design values for flanges which either operate at such high pressures or have such large diameters. Due to this an alternative method of design, by means of non-linear finite element modelling, is proposed. Three types of integral flange designs are considered, namely: flat face, raised face, and a modified raised face with an O-ring groove. The effects of creep-relaxation, flange rotation, and the bolting sequence are considered. For each of these designs a finite element model was created and compared to a small scale experiment which included strain and contact pressure measurements. The proposed non-linear finite element models were capable of accurately predicting the strains in the flanges as well as the contact pressures between the faces of the flange and the surfaces of the packing material. Finally, a comparison between the ASME design method and the proposed non-linear finite element modelling design method was done for the large diameter flanges. It was found that the ASME design code did not have the ability to accurately predict the stresses in the flanges. It was also found that by using the maximum equivalent Von Mises stress as failure criteria for the flanges and fasteners, and contact pressure for the sealing ability, circular bolted flange connections which are lighter, safer, and leak tight could be designed by means of the proposed non-linear finite element models. Dissertation (MEng)--University of Pretoria, 2015. tm2016 Mechanical and Aeronautical Engineering MEng Unrestricted 2016-07-29T11:01:59Z 2016-07-29T11:01:59Z 2016-04-15 2015 Dissertation http://hdl.handle.net/2263/56085 Luyt, ICB 2015, A leak tight design methodology for large diameter flanges based on non-linear modelling and analysis, MEng Dissertation, University of Pretoria, Pretoria, viewed yymmdd <http://hdl.handle.net/2263/56085> A2016 28012942 en © 2016 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria. University of Pretoria |
collection |
NDLTD |
language |
en |
sources |
NDLTD |
topic |
UCTD |
spellingShingle |
UCTD Luyt, Ian Christiaan Berning A leak tight design methodology for large diameter flanges based on non-linear modelling and analysis |
description |
There is currently a need for large diameter flanges for the supply of water in South Africa. These large
diameter pipe flanges are required to accommodate pipes with nominal bores of up to 4 m and should
successfully withstand internal pressures of up to 8 MPa. No current relevant standard / code contains
prescribed design values for flanges which either operate at such high pressures or have such large
diameters. Due to this an alternative method of design, by means of non-linear finite element modelling,
is proposed. Three types of integral flange designs are considered, namely: flat face, raised face, and
a modified raised face with an O-ring groove. The effects of creep-relaxation, flange rotation, and the
bolting sequence are considered.
For each of these designs a finite element model was created and compared to a small scale experiment
which included strain and contact pressure measurements. The proposed non-linear finite element
models were capable of accurately predicting the strains in the flanges as well as the contact pressures
between the faces of the flange and the surfaces of the packing material. Finally, a comparison between
the ASME design method and the proposed non-linear finite element modelling design method was
done for the large diameter flanges. It was found that the ASME design code did not have the ability to
accurately predict the stresses in the flanges. It was also found that by using the maximum equivalent
Von Mises stress as failure criteria for the flanges and fasteners, and contact pressure for the sealing
ability, circular bolted flange connections which are lighter, safer, and leak tight could be designed by
means of the proposed non-linear finite element models. === Dissertation (MEng)--University of Pretoria, 2015. === tm2016 === Mechanical and Aeronautical Engineering === MEng === Unrestricted |
author2 |
Theron, Nicolaas J. |
author_facet |
Theron, Nicolaas J. Luyt, Ian Christiaan Berning |
author |
Luyt, Ian Christiaan Berning |
author_sort |
Luyt, Ian Christiaan Berning |
title |
A leak tight design methodology for large diameter flanges based on non-linear modelling and analysis |
title_short |
A leak tight design methodology for large diameter flanges based on non-linear modelling and analysis |
title_full |
A leak tight design methodology for large diameter flanges based on non-linear modelling and analysis |
title_fullStr |
A leak tight design methodology for large diameter flanges based on non-linear modelling and analysis |
title_full_unstemmed |
A leak tight design methodology for large diameter flanges based on non-linear modelling and analysis |
title_sort |
leak tight design methodology for large diameter flanges based on non-linear modelling and analysis |
publisher |
University of Pretoria |
publishDate |
2016 |
url |
http://hdl.handle.net/2263/56085 Luyt, ICB 2015, A leak tight design methodology for large diameter flanges based on non-linear modelling and analysis, MEng Dissertation, University of Pretoria, Pretoria, viewed yymmdd <http://hdl.handle.net/2263/56085> |
work_keys_str_mv |
AT luytianchristiaanberning aleaktightdesignmethodologyforlargediameterflangesbasedonnonlinearmodellingandanalysis AT luytianchristiaanberning leaktightdesignmethodologyforlargediameterflangesbasedonnonlinearmodellingandanalysis |
_version_ |
1719316687773237248 |