The oxygen performance of a contact lens on the human eye.

There is considerable evidence to indicate that most gas permeable contact lenses do not transmit sufficient oxygen to supply all the corneal oxygen requirement. This problem is further exacerbated by non-valid methods of characterizing the oxygen performance of such lenses. The current methods of u...

Full description

Bibliographic Details
Main Author: Postum, Krishnachand.
Other Authors: Turnbull, D. K.
Language:en_ZA
Published: 2013
Subjects:
Online Access:http://hdl.handle.net/10413/9790
id ndltd-netd.ac.za-oai-union.ndltd.org-ukzn-oai-http---researchspace.ukzn.ac.za-10413-9790
record_format oai_dc
spelling ndltd-netd.ac.za-oai-union.ndltd.org-ukzn-oai-http---researchspace.ukzn.ac.za-10413-97902014-02-08T03:49:18ZThe oxygen performance of a contact lens on the human eye.Postum, Krishnachand.Contact lenses.Theses--Optometry.There is considerable evidence to indicate that most gas permeable contact lenses do not transmit sufficient oxygen to supply all the corneal oxygen requirement. This problem is further exacerbated by non-valid methods of characterizing the oxygen performance of such lenses. The current methods of using oxygen permeability (Dk) and oxygen transmissibility (Dk/L) as indices of oxygen performance of contact lenses is completely erroneous. Dk and Dk/L pertain to contact lens materials in flat sheet form having uniform thickness and equal diffusion path at all points on the surface. Finished contact lenses, of necessity, are curved surfaces and of varying thickness. Consequently the concept of Dk and Dk/L cannot be applied to contact lenses. To date there are no studies to determine the absolute oxygen tension under gas permeable contact lenses on the human eye. All attempts to quantify the oxygen tension under a lens have been by indirect methods or by predicting the p02 from Dk values, using mathematical equations. These results do not match the clinical findings. This study was done to show that oxygen flux through a contact lens, measured in vitro, is a better determinant of the in vivo oxygen performance of gas permeable contact lenses. A special cell was designed to measure the oxygen flux, in vitro under standardised conditions. Contact lens microelectrodes were designed to measure the oxygen tension in vivo. The data obtainedwas used to develop a model for the oxygen performance of rigid gas permeable lenses on the human eye.Thesis (M.Optom.)-University of Durban-Westville, 1989.Turnbull, D. K.Govinden, H. S.2013-10-21T08:44:22Z2013-10-21T08:44:22Z19892013-10-21Thesishttp://hdl.handle.net/10413/9790en_ZA
collection NDLTD
language en_ZA
sources NDLTD
topic Contact lenses.
Theses--Optometry.
spellingShingle Contact lenses.
Theses--Optometry.
Postum, Krishnachand.
The oxygen performance of a contact lens on the human eye.
description There is considerable evidence to indicate that most gas permeable contact lenses do not transmit sufficient oxygen to supply all the corneal oxygen requirement. This problem is further exacerbated by non-valid methods of characterizing the oxygen performance of such lenses. The current methods of using oxygen permeability (Dk) and oxygen transmissibility (Dk/L) as indices of oxygen performance of contact lenses is completely erroneous. Dk and Dk/L pertain to contact lens materials in flat sheet form having uniform thickness and equal diffusion path at all points on the surface. Finished contact lenses, of necessity, are curved surfaces and of varying thickness. Consequently the concept of Dk and Dk/L cannot be applied to contact lenses. To date there are no studies to determine the absolute oxygen tension under gas permeable contact lenses on the human eye. All attempts to quantify the oxygen tension under a lens have been by indirect methods or by predicting the p02 from Dk values, using mathematical equations. These results do not match the clinical findings. This study was done to show that oxygen flux through a contact lens, measured in vitro, is a better determinant of the in vivo oxygen performance of gas permeable contact lenses. A special cell was designed to measure the oxygen flux, in vitro under standardised conditions. Contact lens microelectrodes were designed to measure the oxygen tension in vivo. The data obtainedwas used to develop a model for the oxygen performance of rigid gas permeable lenses on the human eye. === Thesis (M.Optom.)-University of Durban-Westville, 1989.
author2 Turnbull, D. K.
author_facet Turnbull, D. K.
Postum, Krishnachand.
author Postum, Krishnachand.
author_sort Postum, Krishnachand.
title The oxygen performance of a contact lens on the human eye.
title_short The oxygen performance of a contact lens on the human eye.
title_full The oxygen performance of a contact lens on the human eye.
title_fullStr The oxygen performance of a contact lens on the human eye.
title_full_unstemmed The oxygen performance of a contact lens on the human eye.
title_sort oxygen performance of a contact lens on the human eye.
publishDate 2013
url http://hdl.handle.net/10413/9790
work_keys_str_mv AT postumkrishnachand theoxygenperformanceofacontactlensonthehumaneye
AT postumkrishnachand oxygenperformanceofacontactlensonthehumaneye
_version_ 1716637036061917184