The lateral load carrying capacity of wall ties used in cavity wall construction in the Western Cape : a comparison between the Butterfly-type wire tie and the Crimped-type wire tie

Bibliography: leaves 69-71. === The aim of the testing was to compare the relative positives and negatives of the Butterfly Tie and the Crimped lie as regards to water transfer, tensile and compression strengths based on the Australian Code [AS 2699-l 984] requirements as it is more comprehensive. Th...